• Title/Summary/Keyword: elevator safety code

Search Result 13, Processing Time 0.024 seconds

A Current State and an Implication of an Elevator Certification and Inspection System in U.S.A. (미국의 승강기 인증·검사체계의 현황과 시사점)

  • Kim, Young Jin
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.99-104
    • /
    • 2017
  • An undeniable reason for elevator accidents is relevant to diverse defects of elevator itself including a fatal flaw in its managing system. In order to prevent and control disastrous accidents, Korean government established brand new department, Ministry of Public Safety and Security(MPSS) in 2014. For the field of elevator accidents, MPSS, hoping to take the lead, tries to reform related law and statutes. At this time, it is worthwhile to review foreign country's precedent to find out its applicable lesson. This study specially focuses on introducing U.S. legal system dealing with elevator safety area from the viewpoint of stressing the identity of local governments such as state, county, city etc. This article mainly reviews these four points: i) a current state of safety code, guide, standard for elevator in U.S.A. ii) an elevator parts certification system under ASME A.17.1, iii) an elevator inspection system in New York City, iv) an implication of an elevator certification and inspection system in U.S.A. to us.

Behavior Analysis of Small Size Elevator Brake (소형 승강기 제동장치의 거동해석)

  • LEE, Jong-Sun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.2
    • /
    • pp.401-406
    • /
    • 2016
  • Elevator is very important transportation facility of modern society. But there have been frequent elevator accidents recently. In the view of safety management of elevator, the corresponding study must be done since accidents related elevator include not only actual accident but also possible accident in order to protect user from danger. A 3D design was developed using SolidWorks and behavior analysis using FEM Code.

The Integrated Model of CCTV, Remote Control and Direct Call for the Elevator Safety based on Information Technology (IT기반 승강기안전을 위한 CCTV, 원격제어 및 직접통화장치 통합 모델)

  • Kim, Woon-Yong;Park, Seok-Gyu
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.4
    • /
    • pp.697-702
    • /
    • 2012
  • With an elevator supply and demand increases, It has been enlarged various requirements for the safety of the elevator. Elevator safety requirements can be the ability to respond to emergencies quickly. Recently, QR code was attached to all elevator for the elevator safety and it is established by law for the Elevator rescue work. And also the elevator system is seeking to utilize more secure elevator with mandatory installation of CCTV and direct call devices. However, CCTV and direct call service is operating on an individual method and it has not been proposed integrated model. In this paper, we propose the safety elevator integration model with CCTV, direct call service and remote control based on smart phone. Using the proposed model, we can be improved the efficiency of maintenance and ability of prompt action in the event of a disaster.

FEM Analysis of a 38 Person Elevator Brake (38인승 승강기 제동장치의 유한요소해석)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6458-6463
    • /
    • 2014
  • This study performed FEM analysis of a 38 person elevator brake. Recently, an emergency brake was newly developed to improve elevator safety. A 3D design was developed using Solid Works and FEM analysis using analysis code ANSYS. The total deformation, stress and strain were obtained.

A Study on the Improvement of the Evacuation in Ward of the General Hospital (종합병원 병동부 피난환경 개선에 관한 연구)

  • Kim, Woo-Seok;Chai, Choul-Gyun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.202-208
    • /
    • 2006
  • The purpose of this study is to suggest architectural planning guideline for the improvement of the evacuation environment in a ward. To suggest of guideline, the problem of irrational domestic criteria is searched according to compare National fire code (NFPA101, Life safety code) with Korea building law. This study includes stairs, corridors and exit door etc. but excludes fire facilities. To verify effectiveness of suggested guideline, egress simulation is run that based on databases according to literature survey. The results of this study could be summarized as follow: Suggested guidelines are subdivision(fire partition), evacuation by elevator, secure useful waiting space of elevator hall and smokeproof enclosures, the corridor is divided by fire or smoke barriers corridor from hazardous room, only wheeled items are arranged in corridors of a ward story. The result of computer simulation for suggested guidelines verify that egress time can be decreased 20% or above.

Voice Recognition Sensor Driven Elevator for High-rise Vertical Shift (동굴관광용 고층수직이동 승강기의 긴급 음성구동 제어)

  • Choi, Byong-Seob;Kang, Tae-Hyun;Yun, Yeo-Hoon;Jang, Hoon-Gyou;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.88
    • /
    • pp.1-7
    • /
    • 2008
  • Recently, it is one of very interest technology of Human Computer Interaction(HCI). Nowadays, it is easy to find out that, for example, inside SF movies people has talking to computer. However, there are difference between CPU language and ours. So, we focus on connecting to CPU. For 30 years many scientists experienced in that technology. But it is really difficult. Our project goal is making that CPU could understand human voice. First of all the signal through a voice sensor will move to BCD (binary code). That elevator helps out people who wants to move up and down. This product's point is related with people's safety. Using a PWM for motor control by ATmega16, we choose a DC motor to drive it because of making a regular speed elevator. Furthermore, using a voice identification module the elevator driven by voice sensor could operate well up and down perfectly from 1st to 10th floor by PWM control with ATmega16. And, it will be clearly useful for high-rise vertical shift with voice recognition sensor driven.

A research for improvement methods in the aspect of safety engineering through risk analysis of facilities for multiple use - Focused on escalator and passenger conveyors - (다중이용시설물 위험분석을 통한 안전공학적 개선 방안에 관한 연구 (에스컬레이터 및 수평보행기를 중심으로))

  • Kwon, Sun-Geol;Kim, Jin-Soo;Kim, Chang-Eun
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.31-40
    • /
    • 2013
  • For the matter of elevator, one of the multi-use facilities for unspecified public, the JIS has re-established and reformed to apply to the environment in South Korea for the past 20 years. In the aspect of safety assurance, it was inevitable to suggest improved measures. The government, Ministry of Public Administration and Security has secured the safety by enhancing the safety management functions in the elevator inspection standards and expanding its safety device measures. Further, the international inspection standard has been introduced, which is about unifying inspection standard system into the international standard code. In March 14th 2012, the international standard (EN) has been amended and fully announced. Escalator and passenger conveyor among lift devices have several common danger factor that cause safety accident. First, the accident caused by decreased braking power of brake. Second, the accident caused by the rate difference between handrail and tread-board. Third, the accident caused by defects of contraflow preventing device or carelessness inspection. Fourth, the accident caused by wet tread-board or wet floor of platform which makes passenger slip and fall. As the improvements to prevent and reduce these negligent accidents, the inspection list to check and methods should be subdivided and applied for each accident likelihood cause for safety management enhancement and safety assurance of existing escalator and passenger conveyors. The escalators and passenger conveyors without safety devices in existence should be obliged to modify the part of the system or install additional safety device. With making these measures obligations, it requires to improve the system to be suitable for the international inspection standard and to have measures to prevent safety accidents. It also needs to arrange improvements for skid accident of tread-board by the external environment factors such as snow and rain.

Design and Analysis of Dual Rope Brake by Spring Type (양방향 로프 브레이크의 설계 및 해석)

  • Lee Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.319-324
    • /
    • 2006
  • The objective of this study is to design and analyze a dual spring type rope brake. In general, a dual rope brake system are a device for an elevator in safety. Therefore, they are very important and difficult in designing. The finite element model was developed to compute stress, strain and friction force for a dual spring type rope brake. ANSYS code was applied for this investigation.

  • PDF

A Study on the Necessity of Introducing Evacuation Instrument in High-rise Buildings - Focusing on Elevator Type Evacuation Instrument - (고층건축물의 피난기구 도입 필요성에 관한 연구 - 승강식피난기를 중심으로 -)

  • Choi, Kyu-Chool;Ra, Pan-Ju;Seul, Yeong-Mi
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.10-19
    • /
    • 2014
  • The fast evacuation from fire floors to evacuation floors in high-rise building fires can minimize the human damage. In this study, an evacuation instrument, which are applicable to the high-rise buildings of adaptable escape mechanisms by the current NFSC 301 (national fire safety code 301), were selected to analyze the applicability in the high-rise buildings over 11th floor through the site adaptability test. The results of the site test were as follows. The elevator type evacuation instrument of new concept developed as a new technology by compensating the defect of evacuation instrument limiting in the high-rise buildings over 11th floor had completed the stability test and the performance certification test in fire stations, which there were no problems in the introduction of the elevator type evacuation instrument as an escape mechanism in the high-rise buildings. The elevator type evacuation instrument using escapers' weight without using electric power was an escape mechanism that many people could evacuate in a short period of time when a fire broke out in the high-rise buildings. In particular, The elevator type evacuation instrument operated by nonpower had the adaptability as a customized escape mechanism considering user characteristics in the buildings for the disabled or patients with an advanced disease.

Development of Rule-based Checking Modules for the Evacuation Regulations of Super-tall Buildings in Open BIM Environments (개방형BIM환경에서의 룰기반 초고층건축물 피난법규 검토모듈 개발)

  • Kim, Inhan;Choi, Jungsik;Cho, Geunha
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.2
    • /
    • pp.83-92
    • /
    • 2013
  • IFC based open BIM has internationally developed as a solution for interoperability problem among different software applications. Despite much interest and effort, the open BIM technologies are rarely introduced to the construction industry and need more technical development for a practical application as well. This research aims to develop automated code checking modules for quality assurance process of BIM data. The research have analyzed domestic regulations focusing on super-tall buildings and developed open BIM-based code checking modules for the evacuation regulations. The modules are able to validate evacuation regulations such as installation of emergency elevator and fire safety zone. The authors expect to improve the process of BIM quality assurance and enhance the quality of BIM data by this research on automated checking system.