• Title/Summary/Keyword: electrostatic precipitator

Search Result 198, Processing Time 0.027 seconds

A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels (도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구)

  • Koo, Tae Yong;Kim, Yong Min;Hong, Jung Hee;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.79-87
    • /
    • 2013
  • In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-${\varepsilon}$ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.

A Study on the Vibration Characteristics by the Change of Impact Load Direction in the Collecting Plates of Electrostatic Precipitator (충결하중의 방향에 따른 정전집진기 집진판의 진동 특성 연구)

  • 나종문;이기백;양장식
    • Journal of KSNVE
    • /
    • v.5 no.2
    • /
    • pp.247-256
    • /
    • 1995
  • In this paper, double exposure holographic interferometry using ruby pulse laser is formed in order to investigate the propagation of transient waves. The vibration characteristics according to the change of impact load direction, i.e., impacted in the shear direction and in the normal direction are analyzed. It was observed that the macroscopic trends of transient wave generation and propagation in the assembly of precipitator plates were almost similar regardless of the change of impact load direction. But the propagation and mixing of transient wave was advanced relatively slowly when impacted in the normal direction.

  • PDF

Effect of Secondary Flows on the Particle Collection Efficiency in Single Stage Electrostatic Precipitator (1단 전기 집진기에서 2차 유동이 집진 효율에 미치는 영향)

  • Lee, Jae-Bok;Bae, Gwi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.251-259
    • /
    • 2000
  • The ionic wind formed in a nonuniform electric field has been recognized to have a significant effect on particle collection in an electrostatic precipitator(ESP). Under normal operating conditions the effect of ionic wind is not pronounced. However, as the flow velocity becomes smaller, the ionic wind becomes pronounced and induces secondary flow, which has a significant influence on the flow field and the particle collecting efficiency. In this paper, experiments for investigating the effect of secondary flow on collection efficiencies were carried out by changing the flow velocities in 0.2-0.7m/s and the applied voltages in 9-11kV/cm. The particle size distributions and concentrations are measured by DMA and CNC. To analyze the experimental results, numerical analysis of electric filed in ESP was carried out. It shows that particle collection is influenced by two independent dimensionless numbers, $Re_{ehd}\;and\;Re_{flow}$ not by $N_{ehd}$ alone. When $Re_{flow}$, decreases for constant $Re_{ehd}$, the secondary flow prohibits the particle collection. But when $Re_{ehd}$ increases for constant $Re_{flow}$, it enhances the particle collection by driving the particles into the collection region.

Characteristics of Cylindrical Electrostatic Precipitator with Centrifugal Effect (원심력 효과를 고려한 실린더형 전기집진기의 특성)

  • Lee, Joon;Jo, Yong-Soo;Yoa, Seok-Jun
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.351-358
    • /
    • 2001
  • The main purpose of this study was to investigate the characteristics of cylindrical electrostatic precipitator with centrifugal effect in viewpoints of pressure drip and collection efficiency, experimentally. The experiment was carried out for the analysis of current-voltage, pressure drop and collection efficiency with various experimental parameters such as the applied voltage, inlet velocity, inlet size and inlet type(upper and bottom), etc. In the results, the pressure drops were estimated as 27~54, $34~63mmH_2O$ for inlet size $15mm{\tiems}30mm$ and $30mm{\tiems}60mm$, respectively. The collection effeciencies were shown over 90% with the small inlet size($15mm{\tiems}30mm$) for the applied voltage 40kV, inlet velocity(15~21m/s), and 51~89% with the large inlet size ($30mm{\tiems}60mm$). Moreover, in the applied voltage 0kV and inlet size $15mm{\tiems}30mm$, the collection efficiency induced by centrifugal force was represented as about 35% with inlet velocity 15 - 21m/s.

  • PDF

Evaluation of Collection Efficiency of Electrostatic Precipitator for Removing Limestone Slurry Particles (석회석 슬러리 입자 제거를 위한 전기집진기 포집효율 평가)

  • Lee, Gi-Hyuk;Kim, Moon-Won;Yu, Tae-U;Yook, Se-Jin
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.57-65
    • /
    • 2019
  • Recently, there has been much research on the effect of fine dust on human body with increasing interest in the fine dust. Thermal power plant, which is considered as one of the main sources of fine dust, is reported to be responsible for 14% of the total amount of domestic fine dust in the Republic of Korea. Therefore, dust collecting devices in the thermal power plant need to be improved. In this study, the electrostatic precipitator (ESP) was considered to substitute for a mist eliminator used in flue gas desulfurization facility. By considering real situation in the flue gas desulfurization facility, the collection efficiency of the ESP was evaluated by using the sprayed limestone slurry particles. The collection efficiency of the ESP was higher than that of the mist eliminator, showing the possibility of replacing the mist eliminator with the ESP in flue gas desulfurization facility.

Optimization of Flow Uniformity in an Electrostatic Precipitator (ESP) Duct (전기집진기 (ESP) 덕트 내부 유동 균일화를 위한 연구)

  • Junhyung, Hong;Minseung, Hwang;Joungho, Han;Woongchul, Choi;Jeongmo, Seong;Wontae, Hwang
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.86-93
    • /
    • 2022
  • An electrostatic precipitator (ESP) is an industrial post processing facility for high efficiency dust mitigation. Uniformity of the flow passing through the inlet duct leading into the main chamber is important for efficient reduction of dust. To examine flow uniformity, this study conducted a numerical analysis of the flow within a scale-down ESP inlet duct. Magnetic resonance velocimetry (MRV) results from a prior study were utilized to validate the Reynolds-averaged Navier-Stokes (RANS) numerical simulations. Both the experimental and computational results displayed a similar recirculation zone shape and normalized velocity profile near the duct outlet for the baseline geometry. To optimize the uniformity of the flow, the number of guide vanes was modified, and the guide vanes were partially extended straight upward. Design evaluation is done based on the outlet velocity distribution and mass flowrate balance between the two outlets. Simulation results indicate that the vane extension is critical for flow optimization in curved ESP ducts.

Particle Trajectory Visualization in Electrostatic Precipitator (정전집진기내의 입자궤적 가시화)

  • 박석주;김상수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3270-3275
    • /
    • 1994
  • Particle trajectory visualization using laser sheet was performed to investigate the corona wind flow interactions in the one-wire and two-wire type electrostatic precipitators. The corona wind generated by corona discharge was not negligible, and strong flow interactions took place owing to the induced circulatory cells. In the case of one-wire type, as the applied voltage was increased and the cross-section mean velocity was decreased, the effect of corona wind became active. In the case of two-wire type, if upstream discharge voltage was relatively higher than downstream discharge voltage, the effect of upstream corona wind was reduced.

Experimental and Finite Difference Method(FDM) Analysis on Collection Characteristics of Electrostatic Precipitator (전기집지기 집진특성 실험 및 유한차분해석에 관한 연구)

  • 김용진;홍원석;최헌오;함병훈;민춘식;유기선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.49-56
    • /
    • 1994
  • Electrostatic Precipitators( EP ) are widely used in industry for controlling the emission of particulate pollutant Recently, a number of researches have been conducted to solve performance and reliability problems of EP, As a result of researches in the laboratory and of pilot scale, a technology of wide-pitch-spacing has been successfully applied to full scale units. It has been known that the wide-pitch-spacing can reduce the capital cost of newly installed precipitators, and the cost of rebuilding existing uints. In this paper, a systematic study was performed to develop a wide-pitch electrostatic precipitator. The study includes experimental and numerical work on the following : Particle collection characteristics for a bench-scale unit; gas flow characteristics( temperature and velocity distributions): other EP operating variables such as electric Power supply/control. The results are applied directly to design of wide-pitch-spacing EP and the developed numerical model was found to be a good argreement with the experimental results. The EHD simulation program is necessary to design the high efficiency EP.

  • PDF

Characteristics of efficiency by using the combined electrostatic precipitator (조합형 전기집진기를 이용한 집진효율 특성)

  • 김용진;정상현;홍원석;황태근;옥영욱;김두현;하병길;함병훈
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.242-243
    • /
    • 1999
  • 전기집진기는 산업 분진 및 폐가스 집진을 위해 널리 이용되며, 고전기 저항 분진에 의한 집진극 표면의 역전리가 전기집진기에서 가장 큰 문제이다. 이런 역전리 현상을 방지하기 위해 가스온도 제어, 가스조건, 하전 제어 등 다양한 방법이 시도되고 있다. 전기집진기에서 고 비저항 분진 및 역전리의 영향으로부터 높은 집진효율을 얻기 위한 방법 중 하나로 이동 전극형 방식(Moving Electrode Electrostatic precipitator, MEEP)과 고정전극형 (Fixed Electrode Electrostatic precipitatior, FEEP)에 펄스하전 방식으로 구성된 조합형 전기집진기가 개발되고 있다.(Toshiaki Misaka etc. 1996)(중략)

  • PDF

Development of a High Voltage Pulsed Power System for Electrostatic Precipitators (500MW 화력 발전소 전기 집진기용 고압 펄스 전원 장치 개발)

  • Kim, Won-Ho;Gang, Yu-Ri;Lee, Gwang-Hak;Kim, Jong-Su;Im, Geun-Hui;Kim, Cheol-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.12
    • /
    • pp.807-812
    • /
    • 2000
  • With the increasing demands for clean environment, development of air cleaning systems has been received increasing attention. One of the key technologies in the electrostatic precipitator (EP) is high voltage pulsed power supply, which affects the performance of the overall system. In this study, a high voltage microsecond pulse power supply for the EP is developed for 500MW coal power plants. The power supply has dc source and a pulsed one. The ratings of the dc and the pulse source are 60kV, 800mA and 70kV, 400mA, respectively. The width of pulse voltage is 140us and the max. pulse repetition frequency is 200Hz.

  • PDF