• 제목/요약/키워드: electrospray tandem MS

검색결과 137건 처리시간 0.02초

General Fragmentations of Alkaloids in Electrospray Ionization Tandem Mass Spectrometry

  • Shim, Hee Jung;Lee, Ji Ye;Kim, Byungjoo;Hong, Jongki
    • Mass Spectrometry Letters
    • /
    • 제4권4호
    • /
    • pp.79-82
    • /
    • 2013
  • Various types of alkaloids observed in several herbal medicines were analyzed by electrospray ionization tandem mass spectrometry in positive ion mode. In the present study, MS/MS spectralpatterns were investigated for eight-types of alkaloids (aporpine, protoberberine, tetrahydroprotoberberine, benzylisoquinoline, protopine, phthalide, morpine, and bisbenzylisoquinoline). For aporpine- and protoberberine-type alkaloids, main fragmentations occurred at substituted groups on rigid ring structures, not showing ring fusion. Interesting fragmentations due to iminolization and retro-Diels-Alder (RDA) reaction were observed in MS/MS spectra of protopine- and tetrahydroprotobereberine-type alkaloids. Also, several types of fragmentations such as inductive cleavage and ${\alpha}$-cleavage, or bond cleavage between two ring structures were observed depending on their structural characteristics. These fragmentation patterns are expected to allow instant classification of the specific alkaloid type in various MS/MS spectra of alkaloids.

Electrospray Tandem Mass를 이용한 혈중 글리퀴돈의 정량법 개발 및 생체이용률시험 (Electrospray Tandem Mass Spectrometry for the Quantification and Bioavailability Test of Gliquidone in Human Plasma)

  • 문철진;이은희;양송현;문해란
    • 약학회지
    • /
    • 제49권3호
    • /
    • pp.212-216
    • /
    • 2005
  • A rapid, sensitive and selective electrospray tandem mass spectrometric (ESI-LC/MS/MS) method for the quantitation of gliquidone in human plasma was developed. A bioavailability study of gliquidone tablet (30 mg gliquidone, Boehringer Ingelheim Korea Co.) was performed using the validated ESI-LC/MS/MS method. The dose of 30 mg of gliquidone (1 tablet) was orally administered to 9 healthy Korean subjects. After administration, blood was taken at 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 7, 9, 12, 24, and 33 hour. The validation data were as follows; the standard curve was linear ($r^2$=0.999) over the concentration range of $10\~1000 ng/ml$. The coefficient of variation for intra- and inter-day assay were $8.30\~18.86$, and $2.19\~12.92\%$, respectively. The lower limit of quantification for gliquidone was 10 ng/ml. The pharmacokinetic parameters obtained were as follows; $AUC_t$ was 3861.17$\pm$1328.61 ng-hr/ml, $C_{max}$ was 831.02$\pm$227.99 ng/ml, $T_{max}$ was $2.94{\pm}0.77 hr,\;K_e$, was 0.19$\pm$0.06 1/hr, and $t_{l/2}$ was 4.47$\pm$3.52 hr. Based on the validated analytical method and pharmacokinetic parameters, a standard guideline of the bioavailability test of gliquidone dosage forms was prepared successfully and could be used for the bioequivalence test of gliquidone preparation.

LC/MS/MS를 이용한 유기인계 농약류의 최적 분석법 정립과 원·정수에서의 모니터링 (Development of Analytical Method and Monitoring of Organophosphorus Pesticides in the Raw Water and Clean Water by Liquid Chromatography-Tandem Mass Spectrometry)

  • 김경아;송미정;염훈식;손희종;이상원;최진택
    • 한국환경과학회지
    • /
    • 제24권12호
    • /
    • pp.1569-1582
    • /
    • 2015
  • The analytical method for 16 organophosphorus pesticides was developed in this study. The 16 organophosphorus pesticides were analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS) using on-line solid phase extraction (on-line SPE) with PLRP- S cartridge. Analysis of all analytes in the MS/MS was processed in the electrospray ioni-zation (ESI) positive mode. They are Azinphos ethyl, Chlorfenvinphos, Ethion, Famphur, Phosmet, Phosphamidon, Terbufos, Aspon, Chlorpyrifos-methyl, Crotoxyphos, Dichlofenthi-on, Dicrotophos, Fonofos, Thionazin, Dimethoate and Iprobenfos. Limits of detection (LODs) and Limits of quantification(LOQs) were obtained as 0.8~2.0 ng/L and 2.6~6.4 ng/L, respectively. All compounds were not detected at the 8 sampling points of the raw water and clean water.

Study of Complexes of C2- and C6-dihydroceramides with Transition Metal Ions Using Electrospray Ionization Tandem Mass Spectrometry (ESI-MS/MS)

  • Lim, Jin-Yi;Kumar, Avvaru Praveen;Kim, Chang-Dae;Ahn, Chul-Jin;Yoo, Young-Jae;Lee, Yong-Ill
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권2호
    • /
    • pp.397-401
    • /
    • 2009
  • The complexes of $C_2-\;and\;C_6$-dihydroceramides with transition metal ions have been investigated by using Electrospray ionization-tandem mass spectrometry (ESI-MS/MS). The formation and fragmentation pathways of several doubly charged cluster ions as well as singly charged cluster ions of $C_2-\;and\;C_6$-dihydroceramides with transition metal ions have studied by ESI-MS/MS in the positive mode. Under ESI conditions, dihydroceramides form singly and doubly charged complexes with transition metal ions $(Mn^{2+},\;Fe^{2+},\;Co^{2+},\;Ni^{2+},\;and\;Zn^{2+}\;except\;Cu^{2+})$ with the compositions of $[DHCer+M+2H^2O-H]^+,\;[2DHCer+M+2H2O-H]^+,\;[3DHCer+M+2H2O-H]^+,\;[2DHCer+M]^{2+},\;[3DHCer+M]^{2+},\;[4DHCer+M]^{2+},\;[5DHCer+M]^{2+},\;and\;[6DHCer+M]^{2+}\;(DHCer\;=\;C_2-\;or\;C_6$-dihydroceramide, M = transition metal ion). The different complexation behavior of copper is responsible for relatively lower affinity of dihydroceramides to copper compared to those of other transition metals. It is also found that in the mass spectrum of the dihydroceramide complexes with copper(II), [2DHCer+Cu-H]$^+$ was observed with considerable intensity as well as [2DHCer+Cu+2$H_2O-H]^+$ due to its different geometry from those of other metals.

Identification of Ceftiofur Oxidation Products by High-Performance Liquid Chromatography/Electrospray Ionization/Tandem Mass Spectrometry

  • Lim, Young-Hee;Park, Deok-Hie;Youn, Yeu-Young;Kim, Kyung-Hoon;Cho, Hye-Sung
    • Mass Spectrometry Letters
    • /
    • 제2권1호
    • /
    • pp.16-19
    • /
    • 2011
  • Oxidation products of ceftiofur were formed in hydrogen peroxide solution. The structures of the ceftiofur oxidation products were characterized by high-performance liquid chromatography/electrospray ionization/tandem mass spectrometry (HPLC/ESI/MS/MS). The products were identified as compounds oxidized at the sulfur of a cephem ring. For further analysis, experiments were performed using $O^{18}$-labeled hydrogen peroxide. In addition, density-functional calculations were carried out for six possible oxidation products to support the experimental results.

ESI-MS/MS를 이용한 아실카르니틴과 아미노산의 정량분석 (Quantitative Analysis of Acylcarnitines and Amino Acids Using ESI-MS/MS)

  • 김호현;한상범;윤혜란
    • 분석과학
    • /
    • 제14권5호
    • /
    • pp.384-391
    • /
    • 2001
  • 본 연구에서는 ESI-MS/MS를 이용해 혈액내에서 아실카르니틴과 아미노산을 신속하게 정량분석하는 방법을 개발하였다. 아실카르니틴과 아미노산은 3N butanolic hydrogen chloride를 사용하여 유도체화 과정을 거친 뒤 이중질량분석기로 분석하였다. 아실카르니틴은 precursor 85 ion scan을 사용하여 분석하였고, 아미노산들중 알라닌, 발린, 루신/이소루신, 메티오닌, 페닐알라닌, 타이로신, 아스파르트산, 글루탐산 등은 neutral loss 102 scan, 오르니틴과 시트롤린은 neutral loss 119 scan, 글리신은 neutral loss 56 scan, 아르기닌은 neutral loss 161 scan 그리고 아르기니노석시닉산은 product ion 459 scan을 사용하여 분석하였다. 이 방법은 일반적인 액체 크로마토그래피나 아미노산 분석기에 비해서 시료의 전처리가 비교적 간단하며, 높은 감도와 좋은 재현성을 보여주었다.

  • PDF

Electrospray Ionization Mass Spectrometric Observation of Oligomers in Paal-Knorr Synthesis of 2,5-Dimethyl-1-phenylpyrrole

  • Park, So-Young;Chun, Man-Seog;Song, Jin-Su;Kim, Hie-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권4호
    • /
    • pp.575-578
    • /
    • 2005
  • Electrospray ionization mass spectrometry (ESI MS) was used, along with gas chromatography-mass spectrometry (GC-MS), to monitor Paal-Knorr synthesis of 2,5-dimethyl-1-phenylpyrrole by condensation of aniline with 2,5-hexanedione. In addition to 2,5-dimethyl-1-phenylpyrrole observed as a single spot by TLC, unexpected dimer size compounds were observed by GC-MS. Dimers and trimers were observed by ESI MS. ESI tandem mass spectrometry was used to select plausible structures for the dimer. ESI MS with or without liquid chromatographic separation is useful for observing oligomeric byproducts with low volatility produced in organic reactions.

Structural Analysis of [Cu(II)-amyloidogenic peptide] Complexes

  • Cha, Eugene;Seo, Jae-Hong;Kim, Ho-Tae
    • Mass Spectrometry Letters
    • /
    • 제9권1호
    • /
    • pp.17-23
    • /
    • 2018
  • Studies on the interactions of amyloidogenic proteins with trace metals, such as copper, have indicated that the metal ions perform a critical function in the early oligomerization process. Herein, we investigate the effects of Cu(II) ions on the active sequence regions of amyloidogenic proteins using electrospray ionization mass spectrometry (ESI-MS) and collision induced dissociation tandem MS (CID-MS/MS). We chose three amyloidogenic peptides NNQQNY, LYQLEN, and VQIVYK from yeast prion like protein Sup35, insulin chain A, and tau protein, respectively. [Cu-peptide] complexes for all three peptides were observed in the mass spectra. The mass spectra also show that increasing Cu(II) concentrations decrease the population of existing peptide oligomers. The tandem mass spectrum of NNQQNY shows preferential binding for the N-terminal region. All three peptides are likely to appear to be in a Cu-monomer-monomer (Cu-M-M) structure instead of a monomer-Cu-monomer (M-Cu-M) structure.

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권1호
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.