• Title/Summary/Keyword: electronic needle

Search Result 172, Processing Time 0.029 seconds

A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning (부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.

Detection of Partial Discharges by a Monopole Antenna in Insulation Oil (모노폴 안테나를 이용한 유중 부분방전의 검출)

  • Park, Dae-Won;Lee, Jung-Yoon;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.9
    • /
    • pp.727-731
    • /
    • 2012
  • This paper dealt with the measurement and analysis of electromagnetic waves radiated from a partial discharge (PD) source in insulation oil to apply condition monitoring of oil-immersed transformers. Two types of narrow-band monopole antennas with the resonant frequency of a 500 MHz and a 1 GHz were designed and fabricated. Also, a needle-plane electrode system was manufactured to simulate PDs and the curvature radius of the needle is 10 ${\mu}m$ and the diameter of the plane is 60 mm. Electromagnetic wave was measured by the PD measurement system with the monopole antennas. Detection sensitivity of the fabricated antenna was compared for the same PD magnitude; 620 $mV_{peak}$ for the 500 MHz antenna and 960 $mV_{peak}$ for the 1 GHz antenna to the PD magnitude of 74 pC. Consequently, the 1 GHz monopole antenna is more effective to detect PDs in oil-immersed transformers.

The Ion Generation Characteristics of Charge Neutralizer Applied a Pulse Voltage (펄스전압을 적용한 전하중화장치의 이온발생 특성)

  • Moon, Jae-Duk;Chung, Suk-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.140-146
    • /
    • 1998
  • Methods and systems to remove static electricity are requested necessarily because the static electricity causes a flammable gas explosion, a fire, reduction of production rate in manufacturing VLSI semiconductor device and so on. In this paper, abrasion and dust contaminant of needle electrode are studied experimentally. And, frequencies and pulse durations of a high frequency pulse source were controlled effectively to minimize the abrasion of needle electrode and control generated numbers of ions. As a result, it is verified experimentally that the ion generation of charge neutralizer increases by using a high frequency pulse source.

  • PDF

Development and Characterization of Vertical Type Probe Card for High Density Probing Test (고밀도 프로빙 테스트를 위한 수직형 프로브카드의 제작 및 특성분석)

  • Min, Chul-Hong;Kim, Tae-Seon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.9
    • /
    • pp.825-831
    • /
    • 2006
  • As an increase of chip complexity and level of chip integration, chip input/output (I/O) pad pitches are also drastically reduced. With arrival of high complexity SoC (System on Chip) and SiP (System in Package) products, conventional horizontal type probe card showed its limitation on probing density for wafer level test. To enhance probing density, we proposed new vertical type probe card that has the $70{\mu}m$ probe needle with tungsten wire in $80{\mu}m$ micro-drilled hole in ceramic board. To minimize alignment error, micro-drilling conditions are optimized and epoxy-hardening conditions are also optimized to minimize planarity changes. To apply wafer level test for target devices (T5365 256M SDRAM), designed probe card was characterized by probe needle tension for test, contact resistance measurement, leakage current measurement and the planarity test. Compare to conventional probe card with minimum pitch of $50{\sim}125{\mu}m\;and\;2\;{\Omega}$ of average contact resistance, designed probe card showed only $22{\mu}$ of minimum pitch and $1.5{\Omega}$ of average contact resistance. And also, with the nature of vertical probing style, it showed comparably small contact scratch and it can be applied to bumping type chip test.

DSSCs Efficiencies of Photo Electrode Thickness and Modified Photo Electrode Surface Area (광전극 두께와 표면적 변형에 따른 DSSC의 효율 특성)

  • Kwon, Sung-Yeol;Yang, Wook;Zhou, Ze-Yuan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • Photo electrode is an important component for DSSC. DSSCs electrical characteristics and efficiencies fabricated with different $TiO_2$ photo electrodes thickness and modified phoro electrode surface area were studied. $11{\mu}m$ $TiO_2$ photo electrode shows a 4.956% efficiency. The highest short circuit current density was a $9.949mA/cm^2$. Efficiencies and short circuit current density increased as tape casting thickness decreased. Modified surface area of the photo electrode by needle stamp processing were studied. 200 times needle stamp processing on photo electrodes shows a highest 5.168% efficiency. Also the short circuit current density was a $10.261mA/cm^2$.

The Analysis of Water Tree Degradations in Underground Distribution Cables Using Image Measurement (가교폴리에틸렌 지중케이블에서 화상계측을 이용한 수트리 열화현상 분석)

  • Kim, Duck-keun;Lim, Jang-Seob;Lee, Jin;Lee, Joon-Ung;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.19-23
    • /
    • 1998
  • Water tree degradations have been considered as one of the most important causes of failure in underground distribution cables with polymeric insulation. Water tree growth is a preliminary step in the sequence of electrical tree initiation and electrical breakdown of the insulation. In this paper, needle electrode is made use of the etching methods and the pellet type specimen is made to observe the water tree in succession. In previous methods are able to observe the tree degradations without cutting and dyeing. The water tree image is recorded on VTR with CCD camera. The tree length of X, Y axis direction and aging area(treeing area) are calculated with image measurement. As a result of this study, water tree is observed by non-destructive method. Electrical tree is initiated from needle electrode tip only but water tree is initiated from total area of water electrode. Electrical tree owing to water treeing is initiated at low electric field and grown with discontinuously. Namely, water tree is shown up a different characteristics of tree growth.

  • PDF

AC Breakdown Analysis by Epoxy Thickness in Composite-Insulation (복합절연물내의 에폭시 두께에 따른 AC 절연파괴 분석)

  • Jung, Hae-Eun;Yun, Jae-Hun;Kim, Byoung-Chul;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.468-469
    • /
    • 2007
  • $SF_6$ gas used widely as insulating component in electric power industry has excellent in insulation and arc extinguishing performance in gas-insulated switchgear. However, the concern about eco-friendly alternative gas is currently rising, because $SF_6$ gas is one of the main greenhouse gases. As one of the study for $SF_6$ free technology, composite-insulation technology is focused in this paper. To analyze the influence by epoxy thickness change, the composite-insulation composed of dry-air and epoxy was used in this paper. To analyze AC breakdown by the epoxy thickness, needle-plane electrode was used and needle was molded by epoxy. Under the gas pressure ranged from 0.1 to 0.6MPa, the breakdown voltage of dry-air were measured in AC electric field. The data of composite-insulation were acquired by changing the thickness of epoxy used in each composite-insulation under the same condition.

  • PDF

The Hydrogen Generation's Characteristics using Plasma Reactor of Multi-needle Electrode Type (다중침전극형 플라즈마 반응기를 이용한 수소발생 특성)

  • Park, Jae-Yoon;Kim, Jong-Seok;Jung, Jang-Gun;Goh, Hee-Seok;Park, Sang-Hyun;Lee, Hyun-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1246-1251
    • /
    • 2004
  • This paper is investigated about the effect of carrier gas type and the humidity for generating hydrogen gas. The vibration of the water surface is more powerful with increasing applied voltage. In this experimental reactor which is made of multi-needle and plate, the maximum acquired hydrogen production rate is about 3500 ppm. In the experimental result of generating hydrogen gas by non-thermal plasma reactor, the rate of generating hydrogen gas is different with what kind of carrier gas is. We used two types of carrier gas, such as $N_2$ and He. $N_2$ as carrier gas is more efficient to generate hydrogen gas than He because $N_2$ is reacted with $O_2$, which is made from water dissociation. In comparison with water droplet by humidifier and without water droplet by humidifier, the generation of hydrogen gas is decreased in case of water droplet by humidifier. That is the result that the energy for water dissociation is reduced on water surface because a part of plasma energy is absorbed at the small water molecular produced from humidifier.

Acupuncture for Facet Joint Syndrome: A Review of Clinical Study (후관절 증후군의 침 치료에 대한 문헌 연구 보고)

  • Ji-Hyang Gu
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.1
    • /
    • pp.13-29
    • /
    • 2023
  • Objectives To evaluate the evidence supporting the effectiveness of acupuncture for facet joint syndrome. Methods We conducted search across 9 electronic databases (PubMed, EMBASE, Cochrane CENTRAL (CENTRAL), KoreaMed, Kmbase, Koreanstudies Information Service System (KISS), ScienceOn, China National Knowledge Infrastructure (CNKI), and Wanfang) to find clinical trials that used acupuncture as treatment for facet joint syndrome. The methodological quality of randomized controlled clinical trials (RCTs) were assessed using the Cochrane Risk of Bias (RoB) tool, while non-randomized controlled clinical trials (nRCTs) were assessed using the Cochrane Risk of Bias Assessment tool for Non-randomized Study (RoBANS) tool. Results Nine RCTs and one nRCT met our inclusion criteria. Fire needle was more effective than medial branch block in terms of visual analogue scale (VAS) after 1 month (p=0.02). Also, Fire needle was more effective than Ibuprofen in terms of VAS and oswestry disability index (ODI) (p<0.05). However, in the rest of the study results, the intervention group did not show a statistically significant difference than the control group. Conclusions Although our review found encouraging but limited evidence of acupuncture for facet joint syndrome, most of the studies included in the analysis were evaluated as methodologically high risk of bias. From now on further well-designed RCTs should be encouraged.

The efficacy of photobiomodulation on dental injection pain: a systematic review of randomized clinical trials

  • Maryam Altuhafy;Virda Baig;Luay Jabr;Junad Khan
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.24 no.3
    • /
    • pp.145-159
    • /
    • 2024
  • Dental injections are routinely performed and can result in pain and anxiety in patients. This systematic review aimed to evaluate the efficacy of photobiomodulation therapy (PBMT) in dental injections for pain management in patients undergoing dental treatment. Indexed databases, including PubMed, EMBASE, Scopus, ISI Web of Knowledge, and Cochrane Library, were electronically searched without a time limit up to February 2024. A risk of bias evaluation was performed using the Cochrane tool. A preliminary investigation using electronic and manual methods yielded 4,920,881 manuscripts. Based on the eligibility requirements, 13 randomized control trials (RCTs) were included. Self-assessed pain was determined using the visual analog scale, Face, Legs, Activity, Cry, Controllability scale, or Wong-Baker face pain scale. Eight RCTs demonstrated a notable decrease in needle pain in patients undergoing dental needle injections using PBMT. Based on current evidence, PBMT may help reduce needle pain related to dental anesthesia. Further standardized studies are needed to assess the significance of PBMT for postoperative pain in patients undergoing dental injections.