• 제목/요약/키워드: electronic equipment

검색결과 1,561건 처리시간 0.028초

PCM 유닛을 적용한 공기 열원 히트펌프의 연속난방 성능 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Performance of an Air-Source Heat Pump Using a PCM Unit for Continuous Heating)

  • 장민;정동일;정종호;김용찬
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.537-543
    • /
    • 2015
  • Air-source heat pumps are widely used in winter as heating units due to their higher efficiency compared to electronic heaters or gas fired equipment. However, the air-source heat pump can cause discomfort during periodic defrosting operations. In this study, a PCM unit for continuous heating was adopted to solve this problem. The PCM unit consisted of a PCM, a heat exchanger, and control valves. It was installed between the outdoor and indoor units. The performance of the proposed system was measured during both defrosting and heating operations. The indoor unit showed an average leaving temperature of $26^{\circ}C$ after adopting the PCM unit for continuous heating during the defrosting operation.

평균전류모드 플라이백 토폴로지를 이용한 PDP용 고효율 AC-DC 컨버터 및 Hold-up 특성 개선 (High Efficiency AC-DC Converter Using Average-Current Mode Flyback Topology for PDP and Improvement of Hold-up Characteristic)

  • 이경인;임승범;정용민;오은태;이준영
    • 반도체디스플레이기술학회지
    • /
    • 제7권2호
    • /
    • pp.23-27
    • /
    • 2008
  • Recently, regulation for THD (Total Harmonic Distortion) such as IEC 61000-3-2, IEEE 519 is being reinforced about a product which directly connects to AC line in order to prevent distortion of common power source in electronic equipment and electrical machinery. In order to satisfy these regulations, conventional circuits were used two-stage structure attached power factor correction circuit at ahead of converter but this method complicate the circuit and then a number of element increases thereupon the cost of production rises. in this paper, we propose a high efficiency single-stage 300W PFC fly-back converter that improved power factor and efficiency than conventional two-stage power module.

  • PDF

PCB 전송선에서 비아 펜스의 효과 분석 (Analysis of Via Fence Effects in PCB Transmission Lines)

  • 김종호;박상욱;주재철;박동철
    • 한국전자파학회논문지
    • /
    • 제16권4호
    • /
    • pp.402-409
    • /
    • 2005
  • 아날로그 및 디지털 시스템에서 인쇄회로기판에 있는 전송선들의 상호 결합은 장비의 성능을 저하시킬 수 있다. 이 논문에서는 전송선들 사이에 추가로 전송선을 삽입하고 비아 홀을 통해 접지면에 직접 연결시킨 비아펜스의 영향을 해석하기 위한 방법을 제안하였다. 이 방법은 전송선 부분을 위한 회로 개념과 비아 홀 부분을 위한 임피던스 모델링으로 이루어졌고 각 부분을 ABCD 파라미터로 나타내어 직렬 연결하였다. 마지막으로 이 방법에 의한 시뮬레이션 결과를 측정 결과와 비교하여 방법의 타당성을 입증하였다.

복합재 반자율 무인잠수정(SAUV)의 내압선체 설계, 구조해석 및 내압시험 결과에 관한 검토 (A Study on the Results of the Pressure Vessel Design, Structural Analysis, and Pressure Test of the Semi-Autonomous Underwater Vehicle (SAUV))

  • 정태환;이종무;홍석원;김진봉;안진우
    • 한국해양공학회지
    • /
    • 제18권4호
    • /
    • pp.52-58
    • /
    • 2004
  • A Semi-Autonomous Underwater Vehicle (SAUV), capable of simple work on the seabed, is under development in KRISO-KORDI. This SAUV pressure vessel is composed of fiberglass reinforced plastic (FRP), and is also manufactured to carry electronic equipment. The objective of this paper is to describe the safety check for the pressure vessel. This is achieved fly conducting structural analysis and testing in a pressure tank. Strain and stress test results, under unit load, are obtained fly using ANSYS in linear structural analysis. Local buckling analysis are performed with NASTRAN at the middle oj the cylindrical hull. The first test, using linear structural analysis, is unsuccessful, as buckling occurred. During the second test, linear structural analysis, combined with local buckling analysis, is conducted. There is no buckling up to 250 m when both ANSYS and NASTRAN are used.

Intelligent Coordination Method of Multiple Distributed Resources for Harmonic Current Compensation in a Microgrid

  • Kang, Hyun-Koo;Yoo, Choel-Hee;Chung, Il-Yop;Won, Dong-Jun;Moon, Seung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.834-844
    • /
    • 2012
  • Nonlinear electronic loads draw harmonic currents from the power grids that can cause energy loss, miss-operation of power equipment, and other serious problems in the power grids. This paper proposes a harmonic compensation method using multiple distributed resources (DRs) such as small distributed generators (DGs) and battery energy storage systems (BESSs) that are integrated to the power grids through power inverters. For harmonic compensation, DRs should inject additional apparent power to the grids so that certain DRs, especially operated in proximity to their rated power, may possibly reach their maximum current limits. Therefore, intelligent coordination methods of multiple DRs are required for efficient harmonic current compensation considering the power margins of DRs, energy cost, and the battery state-of-charge. The proposed method is based on fuzzy multi-objective optimization so that DRs can cooperate with other DRs to eliminate harmonic currents with optimizing mutually conflicting multi-objectives.

Analysis of Economic Replacement Cycle of Power Transformer Based on LCC Considering Maintenance Effect

  • Park, Seung-Hwa;Jang, Kyeong-Wook;Kweon, Dong-Jin;Shon, Jin-Geun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1631-1637
    • /
    • 2018
  • Electric utilities has been considered the necessity to introduce asset management of electric power facilities in order to reduce maintenance cost of existing facilities and to maximize profit. This paper aims to provide data that can helpful to make profitable decision in terms of power transformers which have a significant part in the power system. Therefore, this study is modeling input cost for power transformer during its entire life and also the life cycle cost (LCC) technique is applied. In particular, the variation of transformer state related with maintenance and the variation of the EUAC curve based on cost and effect of maintenance is examined. In this study, the trend of the equivalent uniform annual cost (EUAC) according to maintenance cycle and cost of equipment is analyzed. In line with that, sensitivity analysis influenced by the changes of other cost factors was performed.

패키지 반도체소자의 ESD 손상에 대한 실험적 연구 (Experimental Investigation of the Electrostatic Discharge(ESD) Damage in Packaged Semiconductor Devices)

  • 김상렬;김두현;강동규
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.94-100
    • /
    • 2002
  • As the use of automatic handling equipment for sensitive semiconductor devices is rapidly increased, manufacturers of electronic components and equipments need to be more alert to the problem of electrostatic discharges(ESD). In order to analyze damage characteristics of semiconductor device damaged by ESD, this study adopts a new charged-device model(CDM), field-induced charged model(FCDM) simulator that is suitable for rapid, routine testing of semiconductor devices and provides a fast and inexpensive test that faithfully represents ESD hazards in plants. High voltage applied to the device under test is raised by the field of non-contacting electrodes in the FCDM simulator, which avoids premature device stressing and permits a faster test cycle. Discharge current and time are measured and calculated. The characteristics of electrostatic attenuation of domestic semiconductor devices are investigated to evaluate the ESD phenomena in the semiconductors. Also, the field charging mechanism, the device thresholds and failure modes are investigated and analyzed. The damaged devices obtained in the simulator are analyzed and evaluated by SEM. The results obtained in this paper can be used to prevent semiconductor devices form ESD hazards and be a foundation of research area and industry relevant to ESD phenomena.

전기 집진기의 집진 효율 향상에 관한 연구 (The Improvement of Collection Efficiency of Electrostatic Precipitator)

  • 안국찬;김봉환;이광석
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.25-30
    • /
    • 2002
  • This paper demonstrates the effects of dust electrical resistivity on electrostatic precipitability. The effects of gas temperature, velocity and humidity on the collection efficency were considered by used of coal fly ashes from fluidized bed combustion boiler. The experiments for collection efficiency were carried out in the pilot plant. The ashes which have non-spherical geometry and high electrical resistivity were used. Electrical resistivity is an important property for the collection efficiency in the electrostatic precipitators. Fly ash resistivity as a function of temperature up $350{\circ}C$ and water concentration(up to 15%) has been experimentally investigated using the resistivity test equipment consisted of the movable electrode, dust cup, and furnace. As the resistivity of fly ash in the operating temperature($150{\circ}C$) of an electrostatic precipitator was measured higher than $1010{\Omega}{\cdot}$cm, flue gas conditioning in the electrostatic precipitator to reduce the resistivity of fly ash is required.

$SiH_4-Ar$ 혼합기체의 평균 에너지에 관한 연구 (Analysis of the Mean Energy in $SiH_4-Ar$ Mixture Gases)

  • 김상남
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.57-61
    • /
    • 2006
  • This paper calculates and gives the analysis of mean energy in pure $SiH_4,\;Ar-SiH_4$ mixture gases ($SiH_4-0.5[%],\;5[%]$) over the range of $E/N =0.01{\sim}300[Td]$, p = 0.1, 1, 5.0 [Torr] by Monte Carlo the Backward prolongation method of the Boltzmann equation using computer simulation without using expensive equipment. The results have been obtained by using the electron collision cross sections by TOF, PT, SST sampling, compared with the experimental data determined by the other author. It also proved the reliability of the electron collision cross sections and shows the practical values of computer simulation. The calculations of electron swarm parameters require the knowledge of several collision cross-sections of electron beam. Thus, published momentum transfer, ionization, vibration, attachment, electronic excitation, and dissociation cross-sections of electrons for $SiH_4$ and Ar, were used. The differences of the transport coefficients of electrons in $SiH_4$, mixtures of $SiH_4$ and Ar, have been explained by the deduced energy distribution functions for electrons and the complete collision cross-sections for electrons. A two-term approximation of the Boltzmann equation analysis and Monte Carlo simulation have been used to study electron transport coefficients.

공장전기설비의 누전차단기 오동작 조사 및 전력품질분석 (Power Quality Analysis and Failure Survey of Earth Leakage Breakers in Factory Electrical Installation)

  • 이상익;최규하
    • 전력전자학회논문지
    • /
    • 제13권1호
    • /
    • pp.15-21
    • /
    • 2008
  • 공장전기설비에서 개인용 컴퓨터, 정류기, 전기로와 시험장치 등의 비선형 부하 사용 증가에 따른 고조파 발생으로 누전차단기가 오동작하거나 불필요 동작을 하고 있다. 따라서 공장전기설비의 안전관리자를 대상으로 누전차단기의 오동작 상태에 대한 조사를 실시하였다. 또한 누전차단기가 오동작하거나 불필요 동작을 하고 있다는 수용가에서 전압, 전류, 고조파와 불평형 등 전력품질을 측정하고 분석하였다. 본 연구결과는 왜형된 전류파형으로 누전차단기의 트립특성 시험과 누전차단기 오동작 원인분석시 자료로 활용하고자 한다.