Abstract

This paper demonstrates the effects of dust electrical resistivity on electrostatic precipitability. The effects of gas temperature, velocity and humidity on the collection efficency were considered by used of coal fly ashes from fluidized bed combustion boiler. The experiments for collection efficiency were carried out in the pilot plant. The ashes which have non-spherical geometry and high electrical resistivity were used. Electrical resistivity is an important property for the collection efficiency in the electrostatic precipitators. Fly ash resistivity as a function of temperature up $350{\circ}C$ and water concentration(up to 15%) has been experimentally investigated using the resistivity test equipment consisted of the movable electrode, dust cup, and furnace. As the resistivity of fly ash in the operating temperature($150{\circ}C$) of an electrostatic precipitator was measured higher than $1010{\Omega}{\cdot}$cm, flue gas conditioning in the electrostatic precipitator to reduce the resistivity of fly ash is required.

Keywords

References

  1. White, H. J., 'Chemical and Physical Particle Conductivity Factors in Electrostatic Precipitation', Chemical Engineering Progress, Vol. 52, No. 6, pp. 244-248, 1956
  2. Flagan, R. C. and Seinfeld, J. R, 'Fundamentals of Air Pollution Engineering', Prentice Hall, 1988
  3. Sabert, O. J. and Nichols, G. B., 'Electrostatic Precipitation', MARCEL DEKKER, INC., 1978
  4. Japanese Industrial Standard, 'Measuring Methods for Dust Resistivity (with parallel electrodes)', JIS B 9915
  5. Bellagamba, B., Liberti, G, Riboldi, E., and Malagnini, G., 'Engineering Aspects of a Pilot ESP Programme', Proc. of the 3rd Int. Conf. on Electmstatic Precipitation, 1987
  6. Korean Industrial Standards, 'Chemical Analysis of Fwe Brick' RS L 3120
  7. Lamb, A. N., 'Variations in the Performance of Electrostatic Precipitators Collecting Fly Ash from Large Boilers', Proc. of the 2nd Int. Con. on Electrostatic Precipitation, 1984
  8. Bickelhaupt, R. E. and Sparks, L. E., 'Fly Ash Resistivity Prediction Improvement with Emphasis on Sulfur Tnoxide', Southern Research Inst., Birmingham, AL, PB86-178126, 1986
  9. Cooperman, G., 'A New Current - Voltage Relation for Duct Precipitators Valid for Low and High Current Densities', IEEE Transations on Industry Applications, Vol. IA-17, No. 2, 1981
  10. Paulson, C. A. J. and Potter, E. C., 'The Pilot Scale Approach to Assessing the Performance of Full-Scale Electrostatic Precipitators', 8th Austmlian Chem. Eng. Conf., Melboume, Austiailia, August 24-27, pp. 75-79, 1980
  11. Potter, E. C., 'Electrostatic Precpitation Technology: A Different Viewpoint', Air Pollution Control Association, Vol. 28, pp. 40-46, 1978 https://doi.org/10.1080/00022470.1978.10470564