• 제목/요약/키워드: electronic counting

검색결과 74건 처리시간 0.034초

An Analysis of 2D Positional Accuracy of Human Bodies Detection Using the Movement of Mono-UWB Radar

  • Kiasari, Mohammad Ahangar;Na, Seung You;Kim, Jin Young
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.149-157
    • /
    • 2014
  • This paper considers the ability of counting and positioning multi-targets by using a mobile UWB radar device. After a background subtraction process, distinguishing between clutters and human body signals, the position of targets will be computed using weighted Gaussian mixture methods. While computer vision offers many advantages, it has limited performance in poor visibility conditions (e.g., at night, haze, fog or smoke). UWB radar can provide a complementary technology for detecting and tracking humans, particularly in poor visibility or through-wall conditions. As we know, for 2D measurement, one method is the use of at least two receiver antennas. Another method is the use of one mobile radar receiver. This paper tried to investigate the position detection of the stationary human body using the movement of one UWB radar module.

실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현 (Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode)

  • 이운근;백광렬;권석근
    • 제어로봇시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

Characteristics of Motion-blur Free TFT-LCD using Short Persistent CCFL in Blinking Backlight Driving

  • Han, Jeong-Min;Ok, Chul-Ho;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권4호
    • /
    • pp.166-169
    • /
    • 2007
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive TN-LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by counting between on time and off time for video signal input during 1 frame (16.7 ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by CCFL blinking drive and TN-LCD overdriving. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

USN/RFID Reader용 저전력 시그마 델타 ADC 변환기 설계에 관한 연구 (Design of Low Power Sigma-delta ADC for USN/RFID Reader)

  • 강이구;한득창;홍승우;이종석;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.800-807
    • /
    • 2006
  • To enhance the conversion speed more fast, we separate the determination process of MSB and LSB with the two independent ADC circuits of the Incremental Sigma Delta ADC. After the 1st Incremental Sigma Delta ADC conversion finished, the 2nd Incremental Sigma Delta ADC conversion start while the 1st Incremental Sigma Delta ADC work on the next input. By determining the MSB and the LSB independently, the ADC conversion speed is improved by two times better than the conventional Extended Counting Incremental Sigma Delta ADC. In processing the 2nd Incremental Sigma Delta ADC, the inverting sample/hold circuit inverts the input the 2nd Incremental Sigma Delta ADC, which is the output of switched capacitor integrator within the 1st Incremental Sigma Delta ADC block. The increased active area is relatively small by the added analog circuit, because the digital circuit area is more large than analog. In this paper, a 14 bit Extended Counting Incremental Sigma-Delta ADC is implemented in $0.25{\mu}m$ CMOS process with a single 2.5 V supply voltage. The conversion speed is about 150 Ksamples/sec at a clock rate of 25 MHz. The 1 MSB is 0.02 V. The active area is $0.50\;x\;0.35mm^{2}$. The averaged power consumption is 1.7 mW.

영상인식 기술을 이용한 프로젝션용접 자동화시스템 (An Automated Projection Welding System using Vision Processing Technique)

  • 박기정;송하주
    • 한국전자통신학회논문지
    • /
    • 제6권4호
    • /
    • pp.517-522
    • /
    • 2011
  • 수작업에 의한 기존의 프로젝션(projection) 용접시스템은 작업자의 부주의로 인한 불량이 자주 발생한다. 본 논문에서는 비전카메라를 사용하여 부품과 제품의 인식, 용접 및 수량 관리를 자동으로 수행하는 프로젝션 용접시스템을 제안한다. 제안 시스템은 비전카메라를 사용하여 용접에 사용되는 부품의 유무와 놓인 상태를 검사한다. 그리고 부품의 용접 후에는 제품 수량 카운터와 드레싱 등의 항목을 자동 갱신한다. 기존 시스템과의 비교 실험을 통해 불량률을 감소시키고 생산성을 높일 수 있음을 보인다.

Bio-functionalization of the Single Layer Graphene for Detecting the Cancer Cell

  • Oh, Hyung Sik;Park, Wanjun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.429.1-429.1
    • /
    • 2014
  • We present a method of surface functionalization of a single layer graphene for linking and detecting MDA-MB-231 human breast cancer cell. The methodology is done by utilizing 1-pyrenebutanoic acid and succinimidyl ester for immobiling CD44 antibodies. This work shows that the single layer graphene is an efficient fixing substance to capture the MDA-MB-231 human breast cancer cell, selectively. The immobilization method of the cancer cell on the graphene layer will be an effective cell counting system. Moreover usage of the linking with non-covalent bonding is expected to develope a sensor scheme of electrical cell-detecting diagnosis system.

  • PDF

FPGA를 이용한 다기능 고속 카운터 구현에 관한 연구 (Research about a multifunction high-speed counter implementation which uses FPGA)

  • 이도향;양오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2112-2114
    • /
    • 2003
  • In this paper, We used FPGA which was high speed counter implementation. It was Counting accurately rather fast so that there were we as a counter facility of the pulse implemented. We constructed wide environment rather because we used H8/3672 with FPGA. This FPGA was sythesized by A54SX72A. FPGA programmed by VHDL for a 208pin PQFP package. The measurement the pulse is possible though it peels off a maximum 200kHz. There is used at a stopping action movement and control of the body.

  • PDF

흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경 (Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study)

  • 정재열;이기남
    • 동의생리병리학회지
    • /
    • 제17권5호
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.

고성능 DSP를 이용한 모터, 엔코더 성능평가 시스템 개발 (Development of Motor, Encoder Evaluation System using High Performance DSP)

  • 장문석;심재홍;이응혁;최상방
    • 반도체디스플레이기술학회지
    • /
    • 제8권4호
    • /
    • pp.77-82
    • /
    • 2009
  • In robot operation, a motor with multi-degree of freedom motion control and an encoder for motor control are needed. To perform precise motion, location, and velocity control, the operation of motor and encoder with superior performance is important. In this paper, we studied performance evaluation system that can evaluate the performance of motor and encoder. The performance of motor and encoder can be evaluated in terms of disconnection check, signal variation count, and U, V, W signal check. Disconnection check verifies signal connection between a motor and an encoder, signal variation check verifies A, B signal by counting the number of signal A, B when a motor revolves, and U, V, W signal check verifies operating direction of a motor. The result is shown at graphic LCD integrated in system, and can be checked in PC with PC communication.

  • PDF

후보자들에 의한 선거의 공정성을 제공하는 모바일 투표 기법 (The Mobile Voting Scheme Providing Voting Fairness Assured by Candidates)

  • 윤성현
    • 디지털융복합연구
    • /
    • 제10권2호
    • /
    • pp.161-169
    • /
    • 2012
  • 선거 시스템을 관리하기 위해서는 많은 비용과 인력이 요구된다. 경제적이고 공정한 선거 시스템 구축을 위해서 전자 투표 기법의 접목은 필수적이다. 특히 스마트폰과 무선 인터넷 사용이 급증하면서 장소에 구애받지 않고 투표할 수 있는 모바일 투표에 대한 관심이 증대하고 있다. 본 논문에서는 후보자들에 의해서 선거의 공정성이 보장되는 모바일 투표 기법을 제안한다. 모바일 전자 투표를 위한 요구사항을 분석하고 법적 구속력이 있는 모바일 ID와 PKI 기반의 서명 키를 생성한다. 제안한 기법에서 투표권은 부인봉쇄 다중서명 기법을 적용하여 후보자들에 의해서 서명된다. 서명된 투표권은 개표 단계에서 모든 후보자들의 동의 없이는 검증할 수 없는 특성을 갖는다.