• 제목/요약/키워드: electronic control

검색결과 7,294건 처리시간 0.046초

Oxide perovskite crystals type ABCO4:application and growth

  • Pajaczkowska, A.
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1996년도 The 9th KACG Technical Annual Meeting and the 3rd Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.258-292
    • /
    • 1996
  • In the last year great interest appears to YBCO thin films preparation on different substrate materials. Preparation of epitaxial film is a very difficult problem. There are many requirements to substrate materials that must be fullfilled. Main problems are lattice mismatch (misfit) and similarity of structure. From paper [1] or follows that difference in interatomic distances and angles of substrate and film is mire important problem than similarity of structure. In this work we present interatomic distances and angle relations between substrate materials belonging to ABCO4 group (where A-Sr or Ca, B-rare earth element, C-Al or Ga) of different orientations and YBCO thin films. There are many materials used as substrates for HTsC thin films. ABCO4 group of compounds is characterized by small dielectric constants (it is necessary for microwave applications of HTsC films), absence of twins and small misfit [2]. There most interesting compounds CaNdAlO4, SrLaAlO4 and SrLaGaO4 were investigated. All these compounds are of pseudo-perovskite structure with space group 14/mmm. This structure is very similar to structure of YBCO. SLG substrate has the lowest misfit (0.3%) and dielectric constant. For preparation of then films of substrates of this group of compound plane of <100> orientation are mainly used. Good quality films of <001> orientations are obtained [3]. In this case not only a-a misfit play role, but c-3b misfit is very important too. Sometimes, for preparation of thin films substrates of <001> and <110> orientations were manufactured [3]. Different misfits for different YBCO faces have been analyzed. It has been found that the mismatching factor for (100) face is very similar to that for (001) face so there is possibility of preparation of thin films on both orientations. SrLaAlO4(SLA) and SrLaGaO4(SLG) crystals of general formula ABCO4 have been grown by the Czochralski method. The quality of SLA and SLG crystals strongly depends on axial gradient of temperature and growth and rotation rates. High quality crystals were obtained at axial gradient of temperature near crystal-melt interface lower than 50℃/cm, growth rate 1-3 mm/h and the rotation rate changing from 10-20pm[4]. Strong anisotropy in morphology of SLA and SLG single crystals grown by the Czochralski method is clearly visible. On the basics of our considerations for ABCO4 type of the tetragonal crystals there can appear {001}, {101}, and {110} faces for ionic type model [5]. Morphology of these crystals depend on ionic-covalent character of bonding and crystal growth parameters. Point defects are observed in crystals and they are reflected in color changes (colorless, yellow, green). Point defects are detected in directions perpendicular to oxide planes and are connected with instability of oxygen position in lattice. To investigate facets formations crystals were doped with Cr3+, Er3+, Pr3+, Ba2+. Chromium greater size ion which is substituted for Al3+ clearly induces faceting. There appear easy {110} faces and SLA crystals crack even then the amount of Cr is below 0.3at.% SLG single crystals are not so sensitive to the content of chromium ions. It was also found that if {110} face appears at the beginning of growth process the crystal changes its color on the plane {110} but it happens only on the shoulder part. The projection of {110} face has a great amount of oxygen positions which can be easy defected. Pure and doped SLA and SLG crystals measured by EPR in the<110> direction show more intensive lines than in other directions which allows to suggest that the amount of oxygen defects on the {110} plane is higher. In order to find the origin of colors and their relation with the crystal stability, a set of SLA and SLG crystals were investigated using optical spectroscopy. The colored samples exhibit an absorption band stretching from the UV absorption edge of the crystal, from about 240 nm to about 550 m. In the case of colorless sample, the absorption spectrum consists of a relatively weak band in the UV region. The spectral position and intensities of absorption bands of SLA are typical for imperfection similar to color centers which may be created in most of oxide crystals by UV and X-radiation. It is pointed out that crystal growth process of polycomponent oxide crystals by Czochralski method depends on the preparation of melt and its stoichiometry, orientation of seed, gradient of temperature at crystal-melt interface, parameters of growth (rotation and pulling rate) and control of red-ox atmosphere during seeding and growth (rotation and pulling rate) and control of red-ox atmosphere during seeding and growth. Growth parameters have an influence on the morphology of crystal-melt interface, type and concentration of defects.

  • PDF

시판 유통 중인 냉동 다진 마늘의 사전 살균 및 조사처리 여부 판별 모니터링 (Identification of Pre-pasteurization or Pre-irradiation Treatment in Frozen Crushed Garlic Commercially Available in Korean Market)

  • 김효영;안재준;김귀란;정진화;박기환;권중호
    • 한국식품영양과학회지
    • /
    • 제42권10호
    • /
    • pp.1673-1681
    • /
    • 2013
  • 시판 냉동 다진 마늘 5종(중국산 3종, 국산 2종)을 대상으로 DEFT/APC, 전자코 분석, PSL, TL 및 ESR 분석을 이용하여 사전살균처리 및 조사 여부를 모니터링 하였다. DEFT/APC 분석 결과 중국산 시료에서 DEFT값(생균수+사균수)은 7.9~8.3 log CFU/g으로 높은 값을 나타내었으나, APC(생균수)는 4.2~4.8 log CFU/g으로 낮은 값을 나타내어 사전살균처리 가능성이 확인되었다. 그러나 국산 시료는 DEFT값과 APC 값의 차이가 크게 나타나지 않아 사전살균처리되지 않은 것으로 판단되었다. 전자코를 이용한 조사여부 스크리닝 결과, 중국산 시료는 미지시료와 1 kGy 조사시료간에 있어서 차이가 불분명하여 조사여부 확인이 어려운 반면, 국산 시료는 그 차이가 명확히 구분되어서 사전 조사처리 되지 않았음을 확인할 수 있었다. PSL 분석 결과, 미지시료 5종 모두 700 이하의 PCs(-)을 나타내었으며, 1 kGy의 선량으로 재조사하여 얻은 PSL ratio 역시 10배 이상으로 나타나, 모든 시료가 사전 조사되지 않은 시료로 확인되었다. 한편 TL 분석에서 $TL_1$ 발광곡선은 국산 2종의 미지시료는 $300^{\circ}C$ 이상에서, 중국산 3종은 $240{\sim}250^{\circ}C$에서 약한 발광곡선을 나타내었다. 이상의 결과를 검증하기 위하여 재조사(1 kGy)에 의한 $TL_2$ 발광곡선을 측정한 결과, 국산 및 중국산 모두 $150{\sim}250^{\circ}C$에서 발광피크를 나타내면서 TL ratio($TL_1/TL_2$)가 0.1 이하로 비 조사(negative)로 나타났다. 그러나 중국산 3종의 $TL_1$ 발광곡선의 온도범위를 고려해 본다면 조사처리의 가능성이 높게 나타났다. 그리하여 ESR 분석을 실시한 결과, 중국산 3종 시료는 미지시료 및 1 kGy 조사시료 모두 방사선 유래의 특이적인 cellulose signal이 관찰되어 $TL_1$ 결과를 잘 뒷받침하였다. 이와 같이 냉동 다진 마늘의 조사여부를 효과적으로 확인하기 위해서는 물리적 분석법의 다중적 활용이 필요한 것으로 나타났다.

초소형 전기 장치에 의한 전기 자극이 치아 이동과 주위 조직 개조에 미치는 효과에 관한 연구 (A study on the effects of Electrical stimulation by the miniature Electric device on the tooth movement and tissue remodeling)

  • 박순정;이영준;박영국
    • 대한치과교정학회지
    • /
    • 제33권4호
    • /
    • pp.279-291
    • /
    • 2003
  • 낮은 강도의 전류는 골세포의 활성화 대사를 증가시키는 것으로 알려져 왔다. 이 연구는 초소형 전기 장치에 의한 전기 자극이 교정적 치아 이동에 미치는 영향을 규명하기 위하여, 체중 3kg내외의 고양이 6마리를 대상으로 가철성 교정장치와 NiTi coil spring(75gm)을 사용하여 상악 견치를 이동시켰다. 실험군측 견치에는 교정력과 간헐적인 $20{\mu}A$의 전기 자극을 가하였고, 대조군측에는 같은 크기의 교정력만을 가한 후 4주 동안의 치아 이동량을 측정하여 비교하였으며, 치아를 중심으로 조직을 절취하여 탈회하고 조직 처리 후 광학 현미경으로 치주조직의 변화를 비교하여 다음과 같은 결론을 얻었다. 1. 28일간의 실험 기간 동안 실험측의 치아 이동량은 대조군에 비하여 현저히 증가하여, 4주후에 실험측의 치아는 대조군에 비하여 37% 증가된 이동량을 기록하였다. 2. 전기 자극을 받은 치아의 치근 견인측에서 대조군에 비하여 조직학적으로 증가된 골형성 양상이 관찰되었다. 3. 28일간의 전기 자극과 교정력으로 실험측 치아의 압박측에서 대조군에 비하여 증가된 골 흡수 양상이 관찰되었다. 4. 실험군 견치 치근 주위 조직에서는 전반적으로 더 많은 수의 조골 및 파골 세포들과 모세 혈관, 골양 조직들이 관찰됨으로써 증가된 조직 세포 활성을 반영하였다. 5. 1일 5시간 동안의 간헐적 전류 자극은 치아 이동량을 증가시키고 조직 개조를 활성화시키는 효과가 있었다. 이상의 결과는 외부에서 가한 낮은 강도의 간헐적 전기 자극으로 교정적 치아 이동량이 많아지고 치주 조직의 개조 활성이 증가됨을 보이므로 초소형 전기 장치에 의한 자극은 치아 이동과 주위 조직 개조를 촉진시킬 가능성이 있을 것으로 평가되었다.

인공부화기의 실시간 중량감지를 위한 로드셀을 이용한 시스템 연구 (Study of system using load cell for real time weight sensing of artificial incubator)

  • 정진형;김애경;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.144-149
    • /
    • 2018
  • 인공부화기 내에 종란이 입란하여 18일간 발생기를 거쳐 발육기로 이란을 한다. 발생기 동안 계태아 무게 손실은 곧 기실형성과 상관되며 적당한 기실 형성은 곧 건강한 초생추와 입란 대비 부화율과도 연결된다. 그러나 국내 부화장의 부화기에는 현재 무게를 측정하는 장치 없이 부화실장과 관계자의 경험과 발육기로 이란시 표준 무게 측정으로 결과적 측면을 습득하는 것이 현실이다. 그로 인하여 부화 중 조기 폐사, 약추, 병약한 초생추 발생이 빈번한 실정이다. 종란 중량 감소를 모니터링하는 것은 발육장치기 안에서의 무게 변화에 따른 병아리 품질과 부화율 성과를 얻는 데에 절대적으로 중요하다. 종란의 크기와 난각질, 노계 군에 따라 수분 손실은 각기 다르다. 발육기 안에서 무게 변화를 실시간 측정하고 그에 따른 환기 변화를 최적화하여 부화율의 증가를 기대할 수 있으며 부화 시 전체 무게의 10~13% 감소를 컨트롤할 수 있는 실시간 측정 시스템의 개발 필요성이 대두된다. 본 연구를 통한 시스템은 기존의 입란과 이란시 직접적으로 일회성을 체크하는 방식으로 발육 기간 내에는 계태아 수분 증발 측정 제어가 불가능하여 부화율에 영향을 못 미치는 시스템과 달리 아두이노 스케치 보드에 로드셀 4개를 병렬로 연결하고 실시간으로 휴대폰, 컴퓨터를 연결하기 위해 Hyper-terminal 프로그램을 이용하여 AT-command 명령어를 활용하여 정상적으로 연동하였다. 블루투스의 통신속도는 15200으로 설정하여 아두이노와 Hyper-terminal 프로그램의 통신 속도를 맞춰주었다. 실시간 모니터링을 하여 인공부화기 내의 계태아 무게의 변화를 육안으로 확인할 수 있도록 시스템을 설계하였다. 이와 같은 방법으로 종란의 부화율 상승 및 건강상태의 향상을 목표로 하였으며 실시간 모니터링으로 인하여 사용자의 편의성을 확대하고자 하였다.

사용자 환경 모니터링을 위한 소형 자가발전 무선 데이터 송수신 시스템 개발 (Fabrication of Portable Self-Powered Wireless Data Transmitting and Receiving System for User Environment Monitoring)

  • 장순민;조수민;정윤수;김재형;김현수;장다연;라윤상;이동한;라문우;최동휘
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.249-254
    • /
    • 2022
  • 최근 반도체와 같은 정보통신 기술의 발전과 함께 사물인터넷(IoT) 기술 발전이 급격히 이루어지면서 센서와 무선 통신 기능을 내장하여 주변 사물 및 환경 조건을 감지 및 분석하여 대응하는 원격 환경 모니터링 기술이 주목받고 있다. 하지만, 기 개발된 원격 환경 모니터링 시스템은 모두 별도의 전원 공급 장치를 필요로 하기 때문에 시·공간적 기기 사용의 제한을 야기하여, 사용자의 불편함을 유발할 수 있다. 따라서, 본 연구에서는 생체 역학적 에너지의 역학적 특성이 고려된 기구학적 설계 기반 전자기 발전 소자(Electromagnetic generator, EMG)를 개발함으로써 이의 에너지 자립형 원격 환경 모니터링 구동을 위한 전원 공급 장치로써 활용한다. 낮은 진동 주기 및 큰 진폭 변화의 역학적 특성을 지닌 생체 역학적 에너지를 효과적으로 이용하기 위해 자석의 기구학적 배치를 통한 깨지기 쉬운 힘의 평형을 유도하는 Levitation-EMG (L-EMG)를 설계했다. 이를 통해, L-EMG는 외부 진동에 민감하게 반응하여 자석과 코일 간의 효과적인 상대 움직임을 야기하여 고품질 전기 에너지 공급을 가능하게 했다. 뿐만 아니라, 실제 환경 감지 센서와 무선 통신 모듈의 필요 전력을 최소화하기 위한 마이크로 컨트롤러(Micro control unit, MCU)를 구성하였으며, 내장기능 중 저전력모드(Sleep mode)를 접목하여 소비전력의 최소화 및 이의 구동시간 증가를 달성했다. 최종적으로 사용자의 편의성을 극대화하기 위해 휴대폰 어플리케이션을 구축하여 손쉽게 주변 환경 모니터링을 가능하게 했다. 따라서, 이번 연구는 생체역학적 에너지를 이용한 에너지 자립형 원격 환경 모니터링 구축 가능성을 검증할 뿐만 아니라, 더 나아가 별도의 외부 전원 없이 주변 환경 모니터링이 가능한 설계 방안을 제시할 수 있다.

한국주요빙계의 소유역에 대한 순간단위권 유도에 관한 연구 (I) (Studies on the Derivation of the Instantaneous Unit Hydrograph for Small Watersheds of Main River Systems in Korea)

  • 이순혁
    • 한국농공학회지
    • /
    • 제19권1호
    • /
    • pp.4296-4311
    • /
    • 1977
  • This study was conducted to derive an Instantaneous Unit Hydrograph for the accurate and reliable unitgraph which can be used to the estimation and control of flood for the development of agricultural water resources and rational design of hydraulic structures. Eight small watersheds were selected as studying basins from Han, Geum, Nakdong, Yeongsan and Inchon River systems which may be considered as a main river systems in Korea. The area of small watersheds are within the range of 85 to 470$\textrm{km}^2$. It is to derive an accurate Instantaneous Unit Hydrograph under the condition of having a short duration of heavy rain and uniform rainfall intensity with the basic and reliable data of rainfall records, pluviographs, records of river stages and of the main river systems mentioned above. Investigation was carried out for the relations between measurable unitgraph and watershed characteristics such as watershed area, A, river length L, and centroid distance of the watershed area, Lca. Especially, this study laid emphasis on the derivation and application of Instantaneous Unit Hydrograph (IUH) by applying Nash's conceptual model and by using an electronic computer. I U H by Nash's conceptual model and I U H by flood routing which can be applied to the ungaged small watersheds were derived and compared with each other to the observed unitgraph. 1 U H for each small watersheds can be solved by using an electronic computer. The results summarized for these studies are as follows; 1. Distribution of uniform rainfall intensity appears in the analysis for the temporal rainfall pattern of selected heavy rainfall event. 2. Mean value of recession constants, Kl, is 0.931 in all watersheds observed. 3. Time to peak discharge, Tp, occurs at the position of 0.02 Tb, base length of hlrdrograph with an indication of lower value than that in larger watersheds. 4. Peak discharge, Qp, in relation to the watershed area, A, and effective rainfall, R, is found to be {{{{ { Q}_{ p} = { 0.895} over { { A}^{0.145 } } }}}} AR having high significance of correlation coefficient, 0.927, between peak discharge, Qp, and effective rainfall, R. Design chart for the peak discharge (refer to Fig. 15) with watershed area and effective rainfall was established by the author. 5. The mean slopes of main streams within the range of 1.46 meters per kilometer to 13.6 meter per kilometer. These indicate higher slopes in the small watersheds than those in larger watersheds. Lengths of main streams are within the range of 9.4 kilometer to 41.75 kilometer, which can be regarded as a short distance. It is remarkable thing that the time of flood concentration was more rapid in the small watersheds than that in the other larger watersheds. 6. Length of main stream, L, in relation to the watershed area, A, is found to be L=2.044A0.48 having a high significance of correlation coefficient, 0.968. 7. Watershed lag, Lg, in hrs in relation to the watershed area, A, and length of main stream, L, was derived as Lg=3.228 A0.904 L-1.293 with a high significance. On the other hand, It was found that watershed lag, Lg, could also be expressed as {{{{Lg=0.247 { ( { LLca} over { SQRT { S} } )}^{ 0.604} }}}} in connection with the product of main stream length and the centroid length of the basin of the watershed area, LLca which could be expressed as a measure of the shape and the size of the watershed with the slopes except watershed area, A. But the latter showed a lower correlation than that of the former in the significance test. Therefore, it can be concluded that watershed lag, Lg, is more closely related with the such watersheds characteristics as watershed area and length of main stream in the small watersheds. Empirical formula for the peak discharge per unit area, qp, ㎥/sec/$\textrm{km}^2$, was derived as qp=10-0.389-0.0424Lg with a high significance, r=0.91. This indicates that the peak discharge per unit area of the unitgraph is in inverse proportion to the watershed lag time. 8. The base length of the unitgraph, Tb, in connection with the watershed lag, Lg, was extra.essed as {{{{ { T}_{ b} =1.14+0.564( { Lg} over {24 } )}}}} which has defined with a high significance. 9. For the derivation of IUH by applying linear conceptual model, the storage constant, K, with the length of main stream, L, and slopes, S, was adopted as {{{{K=0.1197( {L } over { SQRT {S } } )}}}} with a highly significant correlation coefficient, 0.90. Gamma function argument, N, derived with such watershed characteristics as watershed area, A, river length, L, centroid distance of the basin of the watershed area, Lca, and slopes, S, was found to be N=49.2 A1.481L-2.202 Lca-1.297 S-0.112 with a high significance having the F value, 4.83, through analysis of variance. 10. According to the linear conceptual model, Formular established in relation to the time distribution, Peak discharge and time to peak discharge for instantaneous Unit Hydrograph when unit effective rainfall of unitgraph and dimension of watershed area are applied as 10mm, and $\textrm{km}^2$ respectively are as follows; Time distribution of IUH {{{{u(0, t)= { 2.78A} over {K GAMMA (N) } { e}^{-t/k } { (t.K)}^{N-1 } }}}} (㎥/sec) Peak discharge of IUH {{{{ {u(0, t) }_{max } = { 2.78A} over {K GAMMA (N) } { e}^{-(N-1) } { (N-1)}^{N-1 } }}}} (㎥/sec) Time to peak discharge of IUH tp=(N-1)K (hrs) 11. Through mathematical analysis in the recession curve of Hydrograph, It was confirmed that empirical formula of Gamma function argument, N, had connection with recession constant, Kl, peak discharge, QP, and time to peak discharge, tp, as {{{{{ K'} over { { t}_{ p} } = { 1} over {N-1 } - { ln { t} over { { t}_{p } } } over {ln { Q} over { { Q}_{p } } } }}}} where {{{{K'= { 1} over { { lnK}_{1 } } }}}} 12. Linking the two, empirical formulars for storage constant, K, and Gamma function argument, N, into closer relations with each other, derivation of unit hydrograph for the ungaged small watersheds can be established by having formulars for the time distribution and peak discharge of IUH as follows. Time distribution of IUH u(0, t)=23.2 A L-1S1/2 F(N, K, t) (㎥/sec) where {{{{F(N, K, t)= { { e}^{-t/k } { (t/K)}^{N-1 } } over { GAMMA (N) } }}}} Peak discharge of IUH) u(0, t)max=23.2 A L-1S1/2 F(N) (㎥/sec) where {{{{F(N)= { { e}^{-(N-1) } { (N-1)}^{N-1 } } over { GAMMA (N) } }}}} 13. The base length of the Time-Area Diagram for the IUH was given by {{{{C=0.778 { ( { LLca} over { SQRT { S} } )}^{0.423 } }}}} with correlation coefficient, 0.85, which has an indication of the relations to the length of main stream, L, centroid distance of the basin of the watershed area, Lca, and slopes, S. 14. Relative errors in the peak discharge of the IUH by using linear conceptual model and IUH by routing showed to be 2.5 and 16.9 percent respectively to the peak of observed unitgraph. Therefore, it confirmed that the accuracy of IUH using linear conceptual model was approaching more closely to the observed unitgraph than that of the flood routing in the small watersheds.

  • PDF

충돌 정보와 m-bit인식을 이용한 적응형 RFID 충돌 방지 기법 (Adaptive RFID anti-collision scheme using collision information and m-bit identification)

  • 이제율;신종민;양동민
    • 인터넷정보학회논문지
    • /
    • 제14권5호
    • /
    • pp.1-10
    • /
    • 2013
  • RFID(Radio Frequency Identification)시스템은 하나의 RFDI리더, 다수의 RFID태그 장치들로 이루어진 비접촉방식의 근거리 무선 인식 기술이다. RFID태그는 자체적인 연산 수행이 가능한 능동형 태그와 이에 비해 성능은 떨어지지만 저렴한 가격으로 물류 유통에 적합한 수동형 태그로 나눌 수 있다. 데이터 처리 장치는 리더와 연결되어 리더가 전송받은 정보를 처리한다. RFID 시스템은 무선주파수를 이용해 다수의 태그를 빠른 시간에 인식할 수 있다. RFID시스템은 유통, 물류, 운송, 물품관리, 출입 통제, 금융 등 다양한 분야에서 응용되고 있다. 하지만 RFID시스템을 더욱 확산시키기 위해서는 가격, 크기, 전력소모, 보안 등 해결할 문제가 많다. 그 문제들 중에서 본 논문에서는 다수의 수동형 태그를 인식할 때 발생하는 충돌 문제를 해결하기 위한 알고리즘을 제안한다. RFID 시스템에서 다수의 태그를 인식하기 위한 충돌 방지 기법에는 확률적인 방식과 결정적인 방식 그리고 이를 혼합한 하이브리드 방식이 있다. 본 논문에서는 우선 기존에 있던 확률적 방식의 충돌방지기법인 알로하 기반 프로토콜과 결정적 방식의 충돌방지기법인 트리 기반 프로토콜에 대해 소개한다. 알로하 기반 프로토콜은 시간을 슬롯 단위로 나누고 태그들이 각자 임의로 슬롯을 선택하여 자신의 ID를 전송하는 방식이다. 하지만 알로하 기반 프로토콜은 태그가 슬롯을 선택하는 것이 확률적이기 때문에 모든 태그를 인식하는 것을 보장하지 못한다. 반면, 트리 기반의 프로토콜은 리더의 전송 범위 내에 있는 모든 태그를 인식하는 것을 보장한다. 트리 기반의 프로토콜은 리더가 태그에게 질의 하면 태그가 리더에게 응답하는 방식으로 태그를 인식한다. 리더가 질의 할 때, 두 개 이상의 태그가 응답 한다면 충돌이라고 한다. 충돌이 발생하면 리더는 새로운 질의를 만들어 태그에게 전송한다. 즉, 충돌이 자주 발생하면 새로운 질의를 자주 생성해야하기 때문에 속도가 저하된다. 그렇기 때문에 다수의 태그를 빠르게 인식하기 위해서는 충돌을 줄일 수 있는 효율적인 알고리즘이 필요하다. 모든 RFID태그는 96비트의 EPC(Electronic Product Code)의 태그ID를 가진다. 이렇게 제작된 다수의 태그들은 회사 또는 제조업체에 따라 동일한 프리픽스를 가진 유사한 태그ID를 가지게 된다. 이 경우 쿼리 트리 프로토콜을 이용하여 다수의 태그를 인식 하는 경우 충돌이 자주 일어나게 된다. 그 결과 질의-응답 수는 증가하고 유휴 노드가 발생하여 식별 효율 및 속도에 큰 영향을 미치게 된다. 이 문제를 해결하기 위해 충돌 트리 프로토콜과 M-ary 쿼리 트리 프로토콜이 제안되었다. 하지만 충돌 트리 프로토콜은 쿼리 트리 프로토콜과 마찬가지로 한번에 1비트씩 밖에 인식을 못한다는 단점이 있다. 그리고 유사한 태그ID들이 다수 존재할 경우, M-ary 쿼리 트리 프로토콜을 이용해 인식 하면, 불필요한 질의-응답이 증가한다. 본 논문에서는 이러한 문제를 해결하고자 M-ary 쿼리 트리 프로토콜의 매핑 함수를 이용한 m-비트 인식, 맨체스터 코딩을 이용한 태그 ID의 충돌정보, M-ary 쿼리 트리의 깊이를 하나 감소시킬 수 있는 예측 기법을 이용하여 성능을 향상시킨 적응형 M-ary 쿼리트리 프로토콜을 제안한다. 본 논문에서는 기존의 트리기반의 프로토콜과 제안하는 기법을 동일한 조건으로 실험하여 비교 분석 하였다. 그 결과 제안하는 기법은 식별시간, 식별효율 등에서 다른 기법들보다 성능이 우수하다.

전자포탈영상장치(EPID)와 GafChromic EBT3 film을 이용한 다엽콜리메이터 정도관리 시 갠트리 각도 변화에 따른 엽의 위치 정확성 비교 평가 (Comparative evaluation for leaf position accuracy according to gantry angle variation in MLC quality assurance using electronic portal imaging device(EPID) and GafChromic EBT3 film)

  • 양명식;박주경;이승훈;이선영;김정수;권형철;김양수
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.83-91
    • /
    • 2017
  • 목 적: 본 연구에서는 EPID와 GafChromic EBT3 film을 이용하여 picket fence test를 시행하여 갠트리 각도에 따른 중력 효과로 인한 다엽콜리메이터의 엽의 위치 오차를 분석하여 정확성을 평가하고자 하였다. 대상 및 방법: 테이블에 5 cm의 고체 팬텀을 놓고 SAD를 100 cm이 되도록 설정하였다. EBT3 film을 고체 팬텀 위에 정확하게 놓이게 한 후 1.5 cm의 고체 팬텀을 놓고 picket fence test를 시행하였다. EPID는 선원 검출기간 거리 100 cm에서 EBT3 film과 같은 조건으로 측정했다. 갠트리 각도에 따른 다엽콜리메이터 이동 위치를 알아보기 위해 갠트리 각도 $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$에서 각각 측정하였다. 다엽콜리메이터의 기하학적 평가를 위해 분석 프로그램을 이용하여 다엽콜리메이터의 엽의 위치 정확성을 분석하였다. 결 과: EPID의 경우 갠트리 각도 $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$로 갠트리 각도를 변경했을 때 엽의 위치 오차는 각각 평균 0.18 mm, 0.31 mm, 0.20 mm, 0.26 mm였고, 오차의 최댓값은 각각 0.44 mm, 0.54 mm, 0.34 mm, 0.44 mm였다. EBT3 film은 갠트리 각도 $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$로 갠트리 각도를 변경했을 때 엽의 위치 오차는 각각 평균 0.19 mm, 0.21 mm, 0.19 mm, 0.31 mm였고, 오차의 최댓값은 각각 0.35 mm, 0.45 mm, 0.36 mm, 0.48 mm였다. 결 론: 본 연구는 갠트리 각도에 따른 다엽콜리메이터의 엽의 위치 오류를 분석해본 결과 중력효과에 의한 엽의 위치 오류를 확인하였고, EPID와 EBT3 film을 이용하여 갠트리 각도 변화에 따른 엽의 정확성을 비교한 결과 EPID을 이용한 오차 분석방법에서 EBT3 film보다 더 큰 오차가 발생했다. 따라서 다엽콜리메이터를 기반으로 하는 세기조절방사선치료의 경우 정확한 선량 조사에 대한 검증뿐만 아니라 다엽콜리메이터의 정확하고 정밀한 작동에 대한 정도관리와 분석방법에 대한 비교 및 검증이 필요할 것으로 사료된다.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가 (Using CR System at the Department of Radiation Oncology PACS Evaluation)

  • 홍성일;김영재
    • 한국방사선학회논문지
    • /
    • 제6권2호
    • /
    • pp.143-149
    • /
    • 2012
  • 오늘날 의료영상매체의 획기적인 발전으로 각 병원에서 최신 의료장비를 도입함으로써 첨단화, 디지털화로 급변하는 추세이다. 이러한 움직임에 발맞추어 방사선 종양학과에서도 CR system을 도입하여 film system의 단점을 보완하고 병원에서 사용하고 있는 Picture Archiving and Communication System(PACS)과 Electronic Medical Record (EMR) , 그리고 Radiation therapy Treatment Planning system(RTP)의 network를 원활히 하여 업무효율 증대 및 환자에 대한 의료의 질 개선과 서비스 향상을 이루고자 하고 있는데, 방사선 종양학과의 Computed Radiography system(CR system)을 이용하여 PACS에 통합한 사례를 소개하고 그 유용성을 평가하고자 한다. 의료용 선형가속기인 MEVATRON-MX를 이용하여 현재 시행하고 있는 정도관리 중 Gantry, Collimator Star Shot, Light vs. Radiation Field Accuracy, HDR QA(Dwell position accuracy)를 시행하여 PACS 상에 구현하였고 모니터 상에서 디지털 영상을 통한 QA가 가능한지 확인하였다. 또한, 현재 S병원에서 사용 중인 Operation Control System(OCS)과 연동하여 치료에 필요한 코드를 각각의 치료에 부과하여 네트워크로 연결, CR상에 입력한 order가 나타나도록 하였으며, Planning System인 Pinacle과 PACS상의 지원 data 오류를 해결하여 PACS 상에서도 Planning 영상을 볼 수 있도록 하였다. CR system을 이용하여 L-gram, simulation image, planning image를 병원 내 어느 곳에서나 영상을 조회하고 볼 수 있게 PACS에 통합 구축되어있다. Filmless 환경에서 Dosimetry용 IP를 이용하여 Light/Radition field size 일치, gantry rotation axis의 정확성, collimator rotation axis의 정확성, brachy therapy의 Dwell position check등 QA의 시행이 가능하였다. CR system을 이용하여 방사선 종양학과에서 얻어지는 영상을 PACS에 통합함으로써 작업시간 단축과 그에 따른 불필요한 인력소모의 감소 등으로 인하여 업무효율이 증대되었지만 향후 환자정보에 대한 보안을 필요로 한다.