• Title/Summary/Keyword: electron therapy

Search Result 308, Processing Time 0.025 seconds

A case of regression of atypical dense deposit disease without C3 deposition in a child

  • Kim, Min-Sun;Hwang, Pyoung-Han;Kang, Mung-Jae;Lee, Dae-Yeol
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.7
    • /
    • pp.766-769
    • /
    • 2010
  • Dense deposit disease (DDD) is a rare disorder characterized by the deposition of abnormal electron-dense material within the glomerular basement membrane of the kidneys. The diagnosis is made in most patients between 5 and 15 years of age, and within 10 years, approximately half of the affected patients progress to end-stage renal disease. We report a rare case of regressive DDD without C3 deposition after steroid therapy in an 11-year-old boy. The patient presented with edema, gross hematuria, and nephrotic-range proteinuria. Laboratory testing revealed a serum creatinine level of 1.17 mg/dL, albumin level of 2.3 g/dL, and serum C3 level of 125 mg/dL (range 90-180 mg/dL). The results of the renal biopsy were consistent with DDD without C3 deposition. After 6 weeks of steroid therapy, the nephrotic syndrome completely resolved. The follow-up renal biopsy showed a significant reduction in mesangial proliferation and disappearance of electron-dense deposits in the GBM.

Evaluation of Shielding Performance of 3D Printer Materials for High-energy Electron Radiation Therapy (고 에너지 전자선 치료를 위한 3D 프린터 물질의 차폐 성능평가)

  • Chang-Woo, Oh;Sang-Il, Bae;Young-Min, Moon;Hyun-Kyoung, Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.687-695
    • /
    • 2022
  • To find a 3D printer material that can replace lead used as a shield for high-energy electron beam treatment, the shielding composites were simulated by using MCNP6 programs. The Percent Depth Dose (PDD), Flatness, and Symmetry of linear accelerators emitting high-energy electron beams were measured, and the linear accelerator was compared with MCNP6 after simulation, confirming that the source term between the actual measurement and simulation was consistent. By simulating the lead shield, the appropriate thickness of the lead shield capable of shielding 95% or more of the absorbed dose was selected. Based on the absorption dose data for lead shield with a thickness of 3 mm, the shielding performance was analyzed by simulating 1, 5, 10, and 15 mm thicknesses of ABS+W (10%), ABS+Bi (10%), and PLA+Fe (10%). Each prototype was manufactured with a 3D printer, measured and analyzed under the same conditions as in the simulation, and found that when ABS+W (10%) material was formed to have a thickness of at least 10mm, it had a shielding performance that could replace lead with a thickness of 3mm. The surface morphology and atomic composition of the ABS+W (10%) material were evaluated using a scanning electron microscope (SEM) and an energy dispersive X-ray spectrometer (EDS). From these results, it was confirmed that replacing the commercialized lead shield with ABS+W (10%) material not only produces a shielding effect such as lead, but also can be customized to patients using a 3D printer, which can be very useful for high-energy electron beam treatment.

Monte Carlo Calculation of the Dose Profiles for a 6 MeV Electron Beam with Longitudinal Magnetic Fields

  • Jeong, Dong-Hyeok;Oh, Young-Kee;Kim, Jhin-Kee;Kim, Jeung-Kee;Shin, Kyo-Chul;Kim, Ki-Hwan;Lee, Jeong-Ok;Kang, Jeong-Ku;Moon, Sun-Rock
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.109-112
    • /
    • 2002
  • Using Monte Carlo calculations the effects of longitudinal magnetic fields on the beam profiles produced by clinical electron beam were studied. The Monte Carlo calculations were performed using the EGS4 code system modified to account for external magnetic fields. The beam profiles for a 6 MeV electron beam with longitudinal magnetic fields of 0.5-3.0 T were calculated. As a result of these calculations we found that the penumbra widths can be reduced with increased magnetic fields. This means that the electron therapy benefits from the external magnetic fields.

  • PDF

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

Radiation Treatment of Postmastectomy Lymphangiosarcoma (유방 철제술후 임파육종의 치료 1예)

  • Choi, Ihl-Bong;Kim, Mi-Hee;Gil, Hak-Jun;Kim, Chun-Yul;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.81-84
    • /
    • 1988
  • Since the entity of postmastectomy lymphangiosarcoma was first reported by Stewart and Treves in 1948, postmastectomy lymphangiosarcoma has become a well recognized, uncommon malignant tumor which occurs in the upper extremity following mastectomy for mammary carcinoma. The postmastectomy lymphangiosarcoma occurred at an average age of 63.9 years and at an average of 10 years and 3 months following mastectomy. The lymphangiosarcoma raised from blood and lymphatic vessel. The histologic appearance has been observed edematous dermiss and dilated lymphatics lining with malignant cells. Most authors recommend radical amputation for treatment, either shoulder disarticulation or forequarter amputation. Other modalities of treatment including radiotherapy were considered as ineffetive. The present report provides a case of the regression of postmastectomy lymphangiosarcoma with chronic lymphedema by external irradiation. Radiation therapy was used as primary therapy. Total tumor dose of 6500 cGy in 9 wks was delivered using 6 MV x-ray and 8 MeV electron.

  • PDF

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

Study on the therapeutic effects of interferon and gamma-globulin in experimental Pneumocustis curinii pneumonia (Interferon 및 gamma-globulin이 실험적 Pneumocystis carinii 폐염의 치료에 미치는 영향)

  • 신대환;강대영
    • Parasites, Hosts and Diseases
    • /
    • v.30 no.3
    • /
    • pp.219-226
    • /
    • 1992
  • This study was performed to observe the therapeutic effects of interferon-gamma ($IFN-{\gamma}$) and gamma-globulin (${\gamma}-globulin$) in experimental Pneumocystis carinii pneumonia of immune suppressed mice. After 9 weeks, trimethoprim-sulfamethoxaBole(TMP-SMZ; 10~50 mg/mouse/day), mouse $IFN-{\gamma}(5{\times}10^4$ units/mouse/day) and mouse ${\gamma}-globulin$(20 mg/mouse/day) were administered to the mice for 3 weeks by the experimental group. The therapeutic efficacy was evaluated by body weights, histopatholo단ic and electron microscopic findings of the lungs, and number of p. carinii cysts by Gomori's methenamine silver stain. Body weights of the mice were significantly increased in the group of combination therapy of TMP-SMZ with $IFN-{\gamma}{\;}or{\;}{\gamma}-globulin$, and in the group of TMP- SMZ treatment(p<0.05), however, little effect was found in the group of T-globulin alone. Histopathologic 6ndings of p. carinii pneumonia were much improved in the group of combination therapy of TMP-SMZ with $IFN-{\gamma}$. Treatment with either TMP-SMZ or $IFN-{\gamma}$ significantly reduced the number of cysts in the p. carinii pneumonia, but {\gamma}-globulin alone was ineffective. In electron microscopic findings of p. carinii pneumonia, the number of trophozoites and cysts were reduced by treatment with either TMP-SMZ or $IFN-{\gamma}$, and most of the cysts were empty or containing one or two intracystic bodies. The present results suggested, that combination therapy of TMP-SMZ with $IFN-{\gamma}$ had synergistic effects in treatment of P carinii pneumonia in experi- mental mice.

  • PDF

Effect of Sopung-tang and tDCS on Motor function Recovery and GDNF Expression in Photothrombotic Brain Infarction Induced Rat Model (광혈전 유도 뇌손상 백서에서 소풍탕(疏風湯)과 tDCS의 적용이 운동기능회복과 GDNF 발현에 미치는 영향)

  • Sim, Ki Cheol;Kim, Gi Do;Kim, Kyung Yoon;Chung, Hun Woo;Kim, Gye Yeop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.6
    • /
    • pp.894-901
    • /
    • 2012
  • The effect of Sopung-tang(SPT) and trans-cranial direct current stimulation(tDCS) was investigated in photothrombotic brain infarction(PTI) rats. Sprague-Dawley 80 rats, were divided into four groups. group I was experiental control group(n=20), group II was PTI induced and oral administration of SPT(n=20), group III was PTI induced and tDCS administration(n=20) and group IV was PTI induced and SPT and tDCS administration for 28 days on stroke rats(n=20). Analysis the neurological function test, 25 point behavior functional score test, and immunohistochemistric finding of GDNF expression, and electron microscopy assessment In motor behavior test, the outcome of group IV was significantly difference than the other group, and In immunohistochemistric finding, group II, III, IV were increase GDNF expression on 28 days, In electron microscopy finding, the all groups were degenerated of cell organelles, and synaptic plasticity were improvement of group II, III, IV(especially group IV) These results suggest that, 28days application of SPT and tDCS was the motor function and histopathologic, micro-morphological improvement of motor function recovery and positive influence on synaptic plasticity.

A Study on the Characteristics of Therapy Radiation Detector with Diode (다이오드를 이용한 치료방사선 검출기의 특성에 관한 연구)

  • 이동훈;지영훈
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.129-138
    • /
    • 1995
  • High-energy and high-dose X-ray and electron beam have been used in radiation therapy after developing particle accelerators. It is recommended to irradiate patients exect real dose for improving therapy effectiveness by International Committee on Radiation Units and Measurement. The radiation detector for daily beam checks of medical accelerators is described. Using thirteen silicon diodes, we have designed the diode detector providing information about calibration, beam symmetry, flatness, stability variation according to radiation damage, time and general quality assurance for both photon and eletron beams. we also compared these measurement values with those of using ionization chamber, film and semiconductor dosimeter.

  • PDF

Development of Computer-based 2-D Radiation Therapy Planning System (컴퓨터를 이용한 통합적 2차원 방사선치료계획장치 개발)

  • Suh, T.S.;Yoon, S.C.;Suh, D.Y.;Kim, M.C.;Lee, H.K.;Choe, B.Y.;Shinn, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.64-65
    • /
    • 1998
  • The aim of this work is to develop computerized 2-D radiation therapy planning system. The algorithms to compute dose for photon, electron, radioisotope have been developed, and dose distributions were superimposed on CT or MR images. Using object oriented modeling the structure of program has been designed for the efficient user-interface. Finally, a prototyp of 2-D radiation therapy planning system has been successfully applied in clinical cases for the demonstration.

  • PDF