• 제목/요약/키워드: electron paramagnetic resonance (EPR)

검색결과 62건 처리시간 0.019초

Electron Paramagnetic Resonance of the I2-Doped PBMPV Conducting Polymers

  • Lee, C. H.;Lee, Cheol-Eui;J.-I. Jin;S.-J. Chung
    • Journal of Magnetics
    • /
    • 제2권4호
    • /
    • pp.123-125
    • /
    • 1997
  • We have studied a series of I2-doped poly [2-buthoxy-5-methoxy-1, 4-phenylenevinylene] (PBMPV) conducting polymers by means of electron paramagnetic resonance (EPR) measurements. In this work, the EPR linewidth and spin density were obtained from the EPR intensity and studied as a function of the degree of doping.

  • PDF

Dosimetry Application of Irradiated D-fructose using the Electron Paramagnetic Resonance

  • Son, Phil Kook;Choi, Suk-Won;Kim, Sung Soo;Gwag, Jin Seog
    • Journal of Magnetics
    • /
    • 제17권4호
    • /
    • pp.271-274
    • /
    • 2012
  • We examine dosimetry application of irradiated D-fructose materials using electron paramagnetic resonance (EPR). Consequently, we consider that fructose is one of best dosimetry materials. We found that fructose is one of best candidates for dosimetry due to high linearity tilt of EPR signal intensity as a function of dose, irrelevant to photon energy, constant fading value. Also, our results show that fructose materials can be applied as a radiation detector to very weak radiation doses of 0.001 Gray by using EPR at a low temperature (T = 220 K).

The Low-Radiation Dosimetry Application of "tris" Lyoluminescence using Electron Paramagnetic Resonance at Low Temperature

  • Son, Phil-Kook;Choi, Suk-Won;Kim, Sung-Soo;Gwag, Jin-Seog
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.172-175
    • /
    • 2012
  • We present a method for detecting very weak radiation by analyzing the inner structure of irradiated tris (lyoluminescence) materials using electron paramagnetic resonance (EPR) at low temperature. Organic materials have been looked into for use in emergency dosimetry of inhabitants around radiation accidents. However, this technology has never been applied to imperceptible radiation doses (< 0.5 Gy) because there is no proper method for detecting the change of inner structure of the subject bombed by very weak radiation at room temperature. Our results show that tris materials can be applied as a radiation detectors of very small radiation doses below 0.05 Gray, if EPR is used at low temperature (130 K ${\leq}$ T ${\leq}$ 270 K). The EPR signal intensity from the irradiated-tris sample had barely faded at all after 1 year.

X-선에 조사된 설탕의 전자 상자성 공명 연구 (A Study of Electron Paramagnetic Resonance of Sugar Irradiated X-ray)

  • 옥치일;손필국;허경찬;손종기;이인;김장환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.39-42
    • /
    • 2000
  • When ordinary sugar is exposed to ionizing radiation, a number of free radical are created in sugar, and Electron Paramagnetic Resonance (EPR) signal appears from the sugar because of the paramagnetic property of free radical. In this paper, EPR signal intensity has been measured in x-ray irradiated sugar for various absorbed doses, irradiated dose up to 50 Gy. The EPR intensity signals are increased as the x-ray irradiation increases. Also, the fading value decreased to about 3% in 30day after the irradiation. Therefore, the sugar is a useful material for emergency dosimeter as the free radical dosimetry with the EPR equipment.

  • PDF

Electron Paramagnetic Resonance Study of Bis(N-methyl-2-amino-1-cyclopentenedithiocarboxylato)Copper (II)

  • Woo-Seong Kim;Young-Inn Kim;Sung-Nak Choi
    • Bulletin of the Korean Chemical Society
    • /
    • 제11권2호
    • /
    • pp.85-88
    • /
    • 1990
  • The electron paramagnetic resonance (EPR) spectrum of the copper (II) complex with the 2-methylamino-1-cyclo-pentene-1-dithiocarboxylate (acdc) anion, $Cu(N-CH_3acdc)_2$ has been studied in the diamagnetic host lattices afforded by the corresponding divalent nickel, zinc, cadmium and mercury complexes. EPR parameters of the complex support the exclusive use of sulfur atoms by the ligand in metal binding. A combination of host lattice structure and covalency effects can be account for the observed spin-Hamiltonian parameters.

Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident

  • Jae Seok Kim;Byeong Ryong Park;Minsu Cho;Won Il Jang;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.270-277
    • /
    • 2023
  • Exposure to ionizing radiation induces free radicals in human nails. These free radicals generate a radiation-induced signal (RIS) in electron paramagnetic resonance (EPR) spectroscopy. Compared with the RIS of tooth enamel samples, that in human nails is more affected by moisture and heat, but has the advantages of being sensitive to radiation and easy to collect. The fingernail as a biological sample is applicable in retrospective dosimetry in cases of localized hand exposure accidents. In this study, the dosimetric characteristics of fingernails were analyzed in fingernail clippings collected from Korean donors. The dose response, fading of radiation-induced and mechanically induced signals, treatment method for evaluation of background signal, minimum detectable dose, and minimum detectable mass were investigated to propose a fingernail-EPR dosimetry protocol. In addition, to validate the practicality of the protocol, blind and field experiments were performed in the laboratory and a non-destructive testing facility. The relative biases in the dose assessment result of the blind and field experiments were 8.43% and 21.68% on average between the reference and reconstructed doses. The results of this study suggest that fingernail-EPR dosimetry can be a useful method for the application of retrospective dosimetry in cases of radiological accidents.

Development of a Wideband EPR Spectrometer with Microstrip and Loop Antennas

  • Ponomaryov, A.N.;Choi, K.Y.;Suh, B.J.;Jang, Z.H.
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.178-182
    • /
    • 2013
  • We have developed a new non-conventional electron paramagnetic resonance (EPR) spectrometer, in which no resonant cavity was used. We previously demonstrated a wide frequency range operation of an EPR spectrometer using two loop antennas, one for a microwave transmission and the other for signal detection [1]. In contrast to Ref. [1], the utilization of a microstrip antenna as a transmitter enhanced a capability of wide-band operation. The replacement of conventional capacitors with varactor diodes makes resonance condition easily reproducible without any mechanical action during tuning and matching procedure since the capacitance of the diodes is controlled electronically. The operation of the new EPR spectrometer was tested by measuring a signal of 1,1-diphenil-2-picrylhydrazyl (DPPH) sample in the frequency range of 0.8-2.5 GHz.

Temperature Dependence of Mn2+ Paramagnetic Ion in a Stoichiometric LiNbO3 Single Crystal

  • Yeom, Tae Ho;Lee, Soo Hyung
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.221-224
    • /
    • 2013
  • Electron paramagnetic resonance (EPR) spectra of $Mn^{2+}$ impurity ion in Stoichiometric $LiNbO_3$ single crystal (SLN) was investigated with an X-band EPR spectrometer in the temperature range of 3 K~296 K. The intensity of EPR spectrum of $Mn^{2+}$ ion was increased to 20 K and decreased again below 20 K as the temperature decreases. The zero-field splitting parameter D decreased as the temperature increases. It was suggested that $Mn^{2+}$ ion substitute for $Nb^{5+}$ ion instead of $Li^+$ ion. No changes for hyperfine interaction of $Mn^{2+}$ ion was obtained in the temperature range of 3 K~296 K.

Second intercomparison on electron paramagnetic resonance (EPR) retrospective dosimetry in Korea using hydroxyapatite

  • HyoJin Kim;Jae Seok Kim;Byeong Ryong Park;Seongjae Jang;Han-Ki Jang;Ki-Taek Han;Hoon Choi;Jeongin Kim;In Jung Kim;Yunho Kim;Wi-Ho Ha;Jungil Lee;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4576-4582
    • /
    • 2023
  • The Korea retrospective dosimetry (KREDOS)-electron paramagnetic resonance (EPR) group undertook an intercomparison investigation utilizing hydroxyapatite. This analysis involved four institutions: the Korea Institute of Radiological and Medical Sciences, Dongnam Institute of Radiological and Medical Sciences, Korean Association for Radiation Application, and Radiation Health Institute of Korea Hydro & Nuclear Power. Following the irradiation of the hydroxyapatite sample, the recorded build-up was analyzed. To validate the reliability of the EPR dosimetry findings and enhance its operational performance, a hydroxyapatite dose-response curve was plotted and dosimetry was performed for a blind sample. The proficiency of each laboratory was assessed by employing an interlaboratory comparison methodology. This involved a comparative analysis of the measurement results by calculating the relative bias, z-score, and En value. The results submitted by the participating laboratories demonstrated satisfactory ratings for doses of 1.006, 3.999, and 6.993 Gy. Following the second intercomparison, efforts to optimize their hydroxyapatite-EPR dosimetry systems are underway in the participating laboratories. The current assessment of hydroxyapatite dose yielded the foundational data required to establish the parameters of dental dosimetry. In future, the third intercomparison experiment will be conducted for exploring other materials.

정비조성 LiTaO3 단결정에 대한 열처리 효과 (Thermal Effects on Stoichiometric LiTaO3 Single Crystal)

  • 염태호;이수형
    • 한국자기학회지
    • /
    • 제15권3호
    • /
    • pp.177-180
    • /
    • 2005
  • Czochralski방법을 사용하여 정비조성(stoichiometric)으로 성장시킨 강유전체 $LiTaO_3$, 단결정을 $1000^{\circ}C$$1100^{\circ}C$에서 각각 열처리하였다. 열처리한 시료와 열처리하지 않은 정비조성 $LiTaO_3$ 단결정에 대하여 전자 상자성 공명(EPR : electron paramagnetic resonance) 실험을 하였다. X-band(9.21 GHz) 전자 상자성 공명 스펙트로미터를 사용하여 얻은 $Fe^{3+}$ 상자성 불순물 이온의 공명 흡수선을 분석한 결과 정비조성 $LiTaO_3$ 단결정내의 $Fe^{3+}$ 상자성 불순물 이온의 위치(site location)와 국소 대칭성(local site symmetry)은 열처리 후에도 변화가 없는 것을 알 수 있었다. 그러나 $1000^{\circ}C$$1100^{\circ}C$에서 열처리 한 단결정의 경우에는 $v$ 이온이 $Fe^{2+}$ 이온으로 원자가 상태가 바뀌는 것을 화인 하였다. 또한 유효 스핀 하밀토니안을 이용하여 EPR 상수를 계산하였다.