• Title/Summary/Keyword: electron microscopic

Search Result 1,229, Processing Time 0.027 seconds

Accuracy Improvement of Lattice Parameters Measured from Electron Diffraction Data (전자회절을 이용한 격자상수의 측정 정확도 향상)

  • Lee, Sang-Gil;Song, Kyung;Kim, Jin-Gyu
    • Applied Microscopy
    • /
    • v.41 no.1
    • /
    • pp.75-79
    • /
    • 2011
  • For quantitative analysis of nano-crystal structure, we reported the accuracy improvement method of lattice parameters measured from electron diffraction. For calculation of Au lattice parameters used as a standard crystal structure, it was considered two different acquisition methods (detector and enegy-filter) and three different calculation methods (conventional, least-square and regression fit). As a result, the measurement reliability could be enhanced by using CCD camera which gives higher performance, while energy-filtering did not affect the improvement the camera constant accuracy. Also, the accuracy of lattice parameters could be improved up to $10^{-4}$ order by regression fitting with correction formula. Finally, it is expected that the combination of regression fitting and intensity extraction from energy-filtered precession electron diffraction gives a solution of quantitative structure analysis for unknown nano-crystals.

Application of band-pass filtering techniques for improvement on 3D tomogram (3D Tomogram 향상을 위한 Band-pass Filtering 기술의 활용)

  • Ryu, Keun-Yong;Kim, Soo-Jin;Jung, Hyun-Suk;Kweon, Hee-Seok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.382-383
    • /
    • 2011
  • 초고전압 투과전자현미경으로부터 생산된 2D 이미지들에는 고전압(1250 kV)의 사용으로 인한 다양한 노이즈가 발생한다. 따라서 2D 이미지로부터 3D tomogram으로 재구성시 선명도 향상을 위하여 2D 이미지의 노이즈 제거 과정은 필수적이다. 본 연구에서는 band-pass filtering 기법을 활용하여 노이즈를 상당 부분 제거하였고, 필터링된 이미지로부터 3D tomogram으로 재구성한 경우 band-pass filtering의 효과가 2D 이미지에서 뿐만아니라 3D tomogram으로 재구성 했을 경우에 어떤 대역의 filter radius를 적용해야 더욱 효과가 크다는 사실을 확인하였다.

A Glance of Electron Tomography through 4th International Congress on Electron Tomography (International Congress on Electron Tomography에 대한 간략한 이해와 현황)

  • Rhyu, Im-Joo;Park, Seung-Nam
    • Applied Microscopy
    • /
    • v.38 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • Electron tomography (ET) is an electron microscopic technique for obtaining a 3-D image from any electron microscopy specimen and its application in biomedical science has been increased thanks to development of electron microscopy and related technologies during the last decade. There are few researches on ET in Korea during this period. Although the importance of ET has been recognized recently by many researchers, initial approach to electron tomographic research is not easy for beginners. The 4th International Congress on Electron Tomography (4 ICET) was held on Nov $5{\sim}8$, 2006, at San Diego. The program dealt instrumentation, reconstruction algorithm, visualization/quantitative analysis and electron tomographic presentation of biological specimen and nano particles. 1 have summarized oral presentations and analyzed the posters presented on the meeting. Cryo-electron microscopic system was popular system for ET and followed conventional transmission electron microscopic system. Cultured cell line and tissue were most popular specimens analyzed and microorganisms including bacteria and virus also constituted important specimens. This analysis provides a current state of art in ET research and a guide line for practical application of ET and further research strategies.

Ultrastructure of the Eye in the Atypus coreanus Kim, 1985 (한국땅거미(Atypus coreanus Kim, 1985)의 시각기 미세구조)

  • Kwon, Jung-Kyun;Ko, Myung-Kyoo;Chung, Ho-Sam;Kim, Joo-Pil
    • Applied Microscopy
    • /
    • v.28 no.4
    • /
    • pp.477-490
    • /
    • 1998
  • Most spiders have four pairs of simple eyes. A few families of the spider have their developed eyes to an extent visual cues make up a significant of information to response from the external stimuli. Most spiders respond to the external stimuli around them. Specially, they are very sensitive to vibrations from the air, the ground, their webs, or even the surface of water. The present study was undertaken to examine the evolutionary development and function of eye with the observation of visual ultrastructure of Atypus coreanus Kim, 1985 using the electron microscopy. They have weak mobility, limited territory and low developed eyes. Atypus coreanus was collected from Mt. Ungil, Namyangju-gun, Kyonggi province. The fine structure of these eyes was examined by electron microscopy, and prepard by teasing method for scanning electron microscopic observation. As a result, the eyes of Atypus coreanus was composed of cornea, lens, vitreous body, retina, and rhabdome.

  • PDF

Electron Microscopic Studies on Testicular Leydig Cells of Mice Administered with Testosterone Propionate (Testosterone Propionate 투여로 인한 생쥐 고환(睾丸) Leydig Cell의 형태학적변화(形態學的變化)에 대한 전자현미경적연구(電子顯微鏡的硏究))

  • Lee, Jae Hyun;Lee, Cha Soo
    • Korean Journal of Veterinary Research
    • /
    • v.15 no.2
    • /
    • pp.241-250
    • /
    • 1975
  • The light and electron microscopic observations were carried out in order to know the morphological changes of the testicular Leydig cells in the mouse injected with testosterone propionate for a long period. The results obtained were as follows: With the light microscopic study, atrophy of the Leydig cells and larger sudanophilic lipid granules in the experimental group than normal were observed. 2. By the electron microscopic finding, the small spherical or oval mitochondria, large lipid droplets, a decrease in number of smooth endoplasmic reticutum and distended saccular or vacuolar smooth endoplasmic reticulum were observed in the experimental group. Membranous whorls with droplet increased in number and size in the experimental group.

  • PDF

Circular Fast Fourier Transform Application: A Useful Script for Fast Fourier Transform Data Analysis of High-resolution Transmission Electron Microscopy Image

  • Kim, Jin-Gyu;Yoo, Seung Jo;Kim, Chang-Yeon;Jou, Hyeong-Tae
    • Applied Microscopy
    • /
    • v.44 no.4
    • /
    • pp.138-143
    • /
    • 2014
  • Transmission electron microscope (TEM) is an excellent tool for studying the structure and properties of nanostructured materials. As the development of $C_s$-corrected TEM, the direct analysis of atomic structures of nanostructured materials can be performed in the high-resolution transmission electron microscopy (HRTEM). Especially, fast Fourier transform (FFT) technique in image processing is very useful way to determine the crystal structure of HRTEM images in reciprocal space. To apply FFT technique in HRTEM analysis in more reasonable and friendly manner, we made a new circular region of interest (C-ROI) FFT script and tested it for several HRTEM analysis. Consequentially, it was proved that the new FFT application shows more quantitative and clearer results than conventional FFT script by removing the streaky artifacts in FFT pattern images. Finally, it is expected that the new FFT script gives great advantages for quantitative interpretation of HRTEM images of many nanostructured materials.

Sample Preparation of Ductile Heterogeneity Materials by Ultramicrotomy (연성 이종 재료 시료의 상온 절편 제작법)

  • Chae, Hee-Su;Kweon, Hee-Seok;Je, A-Reum;Lee, Seok-Hoon;Kim, Jin-Gyu
    • Applied Microscopy
    • /
    • v.42 no.1
    • /
    • pp.49-52
    • /
    • 2012
  • For TEM study of biological samples or polymers that are contained in organic structure, it is often required that the sample is prepared by using ultramicrotome and stained with proper agents to increase the contrast of organic structure. In this study, we investigated an efficient TEM sample preparation method for ductile heterogeneity material by using ultramicrotomy. Cryo-ultramicrotomy is a suitable method that is capable of rendering sample hardness for various ductile materials. However, it has several factors to consider, such as experimental cost, working time and finding the optimal staining conditions. To satisfy these considerations, we prepared TEM sample by using ultramicrotome without cryofunction, and secured the sample hardness by applying the staining process prior to ultrathin sectioning. The cross-linked polyethylene structure in the sample was stained with the 2% $RuO_4$ solution in a sealed test tube for 24 hours at $4^{\circ}C$. After the sample staining, ultrathin sections of sample were prepared using ultramicrotome. As a result, it was revealed that the difficulties associated with staining of ultrathin sections prepared by low-temperature conditions were improved. In addition, appropriate staining depth of sample could be selected for sectioning process. The quality of TEM sample obtained by using this method was better than that of cryo-ultramicroscopy. Finally, it is expected that our method could be effectively applied in TEM sample preparation for a variety of nano-bio convergence materials.

Immunohistochemical and Electron Microscopic Studies on Intermediate Filament of Epithelial Cell and Non-Epithelial Cells (상피 및 비상피세포들의 Intermediate Filament에 대한 면역조직화학적 및 전자현미경적 연구)

  • Kim, Il;Kim, Hyo-Sung;Rho, Young-Bok
    • Applied Microscopy
    • /
    • v.21 no.1
    • /
    • pp.46-62
    • /
    • 1991
  • The intermediate filament is one of the most important constituents of the intracytoplasmic cytoskeleton microtubule, actin, myosin and intermediate filament. It is composed of keratin, desmin, vimentin, neurofilament and glial filament, and has important role as a cellular marker, epithelial or mesenchymal origin. So it will be important to differentiated from some poorly or undifferentiated neoplasm to provide adequate therapeutic modalities. This study was performed by using immunohistochemical staining and electron microscopic observation to find out intermediate filaments of epithelial and non-epithelial tumor cells evaluate the degree of differentiation in tumors and therefore to provide some diagnostic and therapeutic modalities. The materials consisted of 83 epithelial and non-epithelial elements bearing 23 normal control, 28 epithelial tumors, and 32 non-epithelial tumors, that are resected for definite treatment at Chosun University Hospital from June, 1988 to June, 1990. Immunohistochemical stain for keratin, desmin and vimentin, and electron microscopic study were performed in all cases. The results obtained were as follows. 1. Immunohistochemical stain for intermediate filament were very useful diagnostic aid for differentiated epithelial tumor to non-epithelial tumor in diagnostic neoplasia. 2. In the electron microscopic finding, the size of intermediate filaments were possible differentiated to cell components of epithelial tumor and non-epithelial tumors.

  • PDF

Cryo-SEM Methodology of Arabidopsis thaliana Stem Using High-Pressure Freezing (고압동결고정을 이용한 애기장대 줄기의 cryo-SEM 분석법)

  • Choi, Yun-Joung;Lee, Kyung-Hwan;Je, A-Reum;Chae, Hee-Su;Jang, Ji-Hoon;Lee, Eun-Ji;Kweon, Hee-Seok
    • Applied Microscopy
    • /
    • v.42 no.2
    • /
    • pp.111-114
    • /
    • 2012
  • The scanning electron microscopy is an ideal technique for examining plant surface at high resolution. Most hydrate samples, however, must be fix and dehydrate for observation in the scanning electron microscope. Because the microscopes operate under high vacuum, most specimens, especially biological samples, cannot withstand water removal by the vacuum system without morphological distortion. Cryo-techniques can observe in their original morphology and structure without various artifacts from conventional sample preparation. Rapid cooling is the method of choice for preparing plant samples for scanning electron microscopy in a defined physiological state. As one of cryo-technique, high-pressure freezing allows for fixation of native non-pretreated samples up to $200{\mu}M$ thick and 2 mm wide with minimal or no ice crystal damage for the freezing procedure. In this study, we could design to optimize structural preservation and imaging by comparing cryo-SEM and convention SEM preparation, and observe a fine, well preserved Arabidopsis stem's inner ultrastructure using HPF and cryo-SEM. These results would suggest a useful method of cryo-preparation and cryo-SEM for plant tissues, especially intratubule and vacuole rich structure.