• 제목/요약/키워드: electromagnetic pulse shielding

검색결과 41건 처리시간 0.035초

비정질 강섬유 보강 시멘트 복합체의 전자파 차폐성능 평가 (Evaluation of Electromagnetic Pulse Shielding Performance of Amorphous Metallic Fiber Reinforced Cement Composite)

  • 이상규;김규용;황의철;손민재;백재욱;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.50-51
    • /
    • 2018
  • In this study, it evaluate the electromagnetic pulse shielding performance of amorphous metallic fiber reinforced cement composite with other steel fiber reinforced cement composite. Hooked-ended steel fiber, smooth steel fiber and amorphous metallic fiber were reinforced 2.0 vol.% in cement composites respectively. The electromagnetic pulse shielding performance was evaluated by MIL-STD-188-125-1. As a result, shielding performance of amorphous metallic fiber reinforced cement composite was higher than Hooked-ended and smooth steel fiber reinforced cement composites. In addition, the relationship between the electrical conductivity and the electromagnetic pulse shielding performance of the cement composite was confirmed.

  • PDF

HEMP를 대상으로 한 도전성 재료 혼입 콘크리트 전자파 차폐 벽체 시스템 개발에 관한 실험적 연구 (An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall System Using Conductive Materials for Shielding High-altitude Electromagnetic Pulse(HEMP))

  • 최현준;최현국;김재영;민태범;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.20-21
    • /
    • 2016
  • In this study, the shielding properties of concrete with conductive materials as shielding material for electromagne- tic pulse(EMP) within 10kHz~18GHz were investigated. The shielding effectiveness of specimens were compared with different entrained materials. The shielding effectiveness were determined according to MIL-STD-188-125-1, IEEE-STD-299 at 28 days of concrete curing. The results of shielding effectiveness did not meet the criteria(80dB) severely.

  • PDF

탄소재료 기반 무기계 도료의 전자파 차폐성능 및 부착성능 평가 (Evaluation of Electromagnetic Pulse Shielding Effectiveness and Bonding Performance of Inorganic Paint based on Carbon Material)

  • 장경필;김상희
    • 한국산학기술학회논문지
    • /
    • 제22권1호
    • /
    • pp.801-807
    • /
    • 2021
  • 전기 전자 부품을 기반으로 하는 통신장비, 컴퓨터, 이동 수단, 전산망, 군사용 장비 등 여러 산업 분야 및 사회기반시설에 있어 전자파 차폐의 필요성이 커지고 있다. 구조물의 전자파 차폐 방법은 차폐 콘크리트, 차폐 문, 차폐 창문과 같이 차폐성능을 가지고 있는 자재를 사용하여 시공하는 방법, 그리고 차폐성능이 없는 재료에 차폐 도료를 코팅하는 방법이 있다. 전자파 차폐 도료는 탄소나노튜브, 흑연, 카본 블랙, 탄소 섬유와 같은 전도성 물질을 사용하여 만들어지며, 일반적으로 사용되고 있는 수성도료에서 전자파 차폐 성능이 추가된 도료이다. 이 연구에서는 전자파 차폐 무기계 도료를 개발하기 위한 목적으로 전도성 흑연, 카본 블랙을 차폐원료로 사용한 도료의 차폐성능 및 부착성능을 평가하였다. 차폐 재료의 종류 및 사용량을 달리한 6개 배합에 대해 차폐성능과 부착강도를 평가하였다. 실험 결과, 전도성 흑연과 카본 블랙을 무게비 1:0.2로 혼합한 배합이 33.6 dB로 차폐성능이 가장 좋은 것으로 확인되었고, 부착성능은 전도성 흑연만 사용한 배합이 1.06 MPa로 가장 높은 것으로 확인되었다.

탄소 재료를 사용한 전자파 차폐 무기계 도료 개발에 관한 실험적 연구 (Experimental Study on the Development of Electromagnetic Pulse Shielding Inorganic Paint Using Carbon Materials)

  • 장경필;송태협
    • 한국건설순환자원학회논문집
    • /
    • 제11권3호
    • /
    • pp.234-243
    • /
    • 2023
  • 전자파(EMP)는 고출력 전자파의 총칭으로 핵무기에서 발생하는 EMP, 비핵 EMP, 자연현상에 의해 발생하는 EMP로 분류된다. 전자파는 통신기기, 휴대폰, 컴퓨터, TV, 교통수단 등 전자기적 요소를 지닌 모든 전자장치에 치명적인 손상을 줄 수 있는 수단이다. 본 연구에서는 탄소 재료를 이용한 EMP 차폐 무기 도료 개발을 위해 탄소 재료의 종류와 함량에 따른 도료의 EMP 차폐성능 평가를 수행하였다. 도료 제조에 사용된 원재료들의 상용성 및 분산성 향상을 분석하기 위해 약 27종의 배합으로 총 2회에 걸쳐 실험을 진행하였고, 전기저항 측정법을 이용하여 EMP 차폐 효과를 평가하였다. 본 연구를 통해 개발된 EMP 차폐 도료를 차폐 콘크리트에 적용한 결과 약 25 dB에서 최대 40 dB까지 차폐성능이 향상되는 것을 확인하였다.

Cu계 금속을 용사한 콘크리트 벽체의 전자파 차폐 성능에 관한 연구 (A Study on the Electromagnetic Pulse Shielding Effect of Concrete Wall Sprayed with Cu-based Metal)

  • 장종민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.18-19
    • /
    • 2020
  • The ElectroMagnetic Pulse (EMP) destroys social infrastructure at once and causes social chaos. However, currently major infrastructures are constructed of concrete that does not have electromagnetic shielding performance. In this study, using the arc metal spraying method is used to evaluate the shielding performance and construction performance of concrete. The electro-magnetic shielding effect is measured by fabricating a shielding room with reference to MIL-STD-188-125, and the construction performance is evaluated by measuring the adhesion strength of thin metal sprayed film-concrete. As a result of the study, when the metal spraying method is applied, the shielding effect is higher than that of the special electro-magnetic shielding concrete, and it is considered to be more economical than the existing metal plate (3~5 mm).

  • PDF

금속 용사 피막의 전기전도도 및 전자파 차폐 특성에 관한 연구 (A Study on the Electrical Conductivity and Electromagnetic Pulse Shielding Characteristics of Metal Sprayed Coating)

  • 장종민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.8-9
    • /
    • 2020
  • In this study, the electrical conductivity and shielding effect were evaluated according to the type of metal and the thickness of Metal sprayed coating. The metals used for the test are Cu, Cu-Ni and Cu-Zn, and the thicknesses were 100, 200, 500 um. Each metal sprayed coating was evaluated for electrical conductivity and electromagnetic shielding effect. When the thickness was 200 ㎛ or more, shielding effect 80 dB or more was satisfied at 1 GHz. However, in the case of Cu-Ni, there is little electrical conductivity at a thickness of 100 um or less due to the generated voids, and electromagnetic wave shielding performance cannot be expected. Therefore, To ensure electromagnetic shielding effect of structures, it is considered that the minimum thickness of metal spraying coating should be 200 um.

  • PDF

Electromagnetic Pulse Shielding Effectiveness and Construction Availability of Cast-In-Place Structures Using Corrugated Metal-Plates

  • Kim, Suk Bong;Yoon, Sangho;Min, Gyung Chan;Ahn, Sungjin;Park, Young Jun
    • 한국건축시공학회지
    • /
    • 제13권1호
    • /
    • pp.84-89
    • /
    • 2013
  • This study aims to examine the effectiveness of electromagnetic pulse shielding in cast-in-place protective shelters using corrugated metal-plates, and then reviews their usability for the Republic of Korea Army. The Korea Corps of Engineering has evaluated corrugated metal-plates as a construction material for cast-in-place structures, which have to defend against mechanical impacts as well as electromagnetic pulses. Corrugated metal-plate is known as a superb mechanical protective material, so much so that it has been employed in ammunition magazines and artillery platforms in the armed forces. Moreover, as a metal, such as steel and copper, it is universally recognized as one of the most effective electromagnetic pulse shielding materials. In addition to effectively shielding from electromagnetic pulses and protecting against mechanical impacts, corrugated metal-plates should prove to be an appropriate construction material for the cast-in-place protective shelter in terms of construction availability and economic feasibility. The shielding effectiveness of the suggested structures is examined based on MIL-STD 188-125-1. A few frequency bands need an increase of 15~30dB in shielding effectiveness because of unbidden apertures caused by flaws associated with welding, assembling, and material deformation. However, allowing for the approximately 40dB of shielding provided by soil; the examined structure, which is buried underground, can offset its shortcomings sufficiently.

아크 금속 용사 공법에 의해 코팅된 콘크리트의 전자기파 차폐 성능 확보를 위한 실험적 연구 (An Experimental Study to Secure Electromagnetic Pulse Shielding Performance of Concrete Coated by an Arc Metal Spraying Process)

  • 장종민;정화랑;이한승
    • 한국건축시공학회지
    • /
    • 제21권6호
    • /
    • pp.519-527
    • /
    • 2021
  • 본 연구에서는 기존의 전자기파 차폐 성능이 없는 콘크리트를 대상으로 아크 금속용사 공법을 적용하여 전자기파 차폐성능을 확보하고자 한다. 이를 위해 금속 코팅의 두께에 전기적 특성을 평가하기 위해서 8 종류의(Cu, CuAl, CuNi, CuZn, Al, Zn, ZnAl, AlMg) 금속들을 두께 100, 200 및 500㎛의 금속 코팅으로 제작하여 4pin-probe로 표면에서의 전기전도도를 측정하였고, KS C 0304에 의거하여 전자기파 차폐 성능 시험을 실시하였다. 금속 코팅 시험 결과를 토대로 전자기파 차폐를 위한 최적의 금속 코팅 두께 200㎛를 제안하였으며, 이를 300×300×100mm 콘크리트 시험체에 용사하여 전자기파 차폐 성능을 분석한 결과 목표 성능 1GHz에서 80dB의 전자기파 차폐 성능이 확보됨을 확인하였다. 하지만 부착 강도의 경우 최대 1.11MPa로 목표 성능 대비 74% 이하로 확인되어 추후 콘크리트 표면에 미세한 요철을 형성하여 부착 성능을 향상시키는 연구가 필요할 것으로 판단된다.

전자파 차폐용 콘크리트 개발에 관한 문헌조사 및 기초물성 연구 (A Literature Review and Experimental Study of Basic Physical Properties about Electromagnetic Shielding Concrete Development)

  • 최현준;최현국;임상우;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.41-42
    • /
    • 2016
  • In this study, the basic properties of concrete with entrained materials as shielding material for electromagnetic pulse(EMP) within 10kHz~1GHz were investigated. The concretes of moderate strength were prepared with different entrained materials. The shielding effectiveness will be determined according to MIL-STD-188-125-1 at 28 days of concrete curing. The results of physical properties were all satisfied of setting criteria.

  • PDF

Zn-Al 합금 선재를 이용한 금속용사 공법 적용 콘크리트의 전자파 차폐 성능 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of EMP Shielding Performance of Concrete Applied with ATMSM Using Zn-Al Alloy Wire)

  • 최현준;박진호;민태범;장현오;이한승
    • 한국건축시공학회지
    • /
    • 제19권3호
    • /
    • pp.209-217
    • /
    • 2019
  • EMP(Electromagnetic Pulse)는 통상적으로 고출력 전자기파 (High Power Electromagnetic: HPEM)를 의미한다. EMP를 차폐하기 위한 차폐 판의 경우, 현장 적용 시, 용접 및 볼트의 연결부(접합부)에서 시공자의 숙련도 및 불량시공, 차폐판의 변형 등으로 인한 전자파 차폐성능 저하의 가능성을 유발하고 있으며, 또한 벽체로부터 이격거리로 인한 비효율적인 공간 활용이 문제점으로 지적 되고 있다. 따라서, 본 연구는 콘크리트 벽체를 대상으로 반사손실에 대한 전자파 차폐성능을 확보하기 위한 일환으로서, 콘크리트에 금속용사 공법을 적용하여 최적의 전자파 차폐 조건을 도출하고자 한다. 실험변수로는 콘크리트 벽체 두께, Zn-Al 금속용사 적용 유무이다. 콘크리트 벽체의 경우, 일반적으로 적용되어지고 있는 벽체 두께인 100~300mm이며, 또한 전자파 차폐성능에 관한 Zn-Al 금속용사 공법의 실효성을 평가하기 위해 적용 유무로 구분하여 실험변수를 설정하였다. 실험 결과 두께가 증가할수록 흡수 손실의 증가로 인해 전자파 차폐성능이 증가하였다. 또한 Zn-Al 금속용사 적용 후 모든 시험체에서 평균 56.68 dB의 상당한 차폐성능 증가를 보였으며, 이는 금속용사 피막의 반사손실에 의하여 증가된 것으로 판단된다. 또한, 전도성 혼입재료와 금속 용사 피막을 동시에 적용할 경우 보다 우수한 차폐성능을 나타낼 것으로 판단된다.