A study on horizontal positing for the seashore reclamation (해안매립을 위한 수평위치 결정에 관한 연구)

  • 문두열
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.113-121
    • /
    • 1997
  • With the increase use of electromagnrtic distance measuring equiment, is is required that we need to study the higher dimensional applications and detail technical methods. The purpose of this paper is to improve the accuracy of ocean construction surveying and computer programming for determining of horizontal position of a quadrilateral by measuring line on traverse surveyng, trigulation and trilateration. Aa long distance measurements with high accuracy became possible by the apperance of EDM distance measuring instruments, we induced correct adjustment equation through angle condition and area conditionequation. After that we compared and experimental model. From its a result of the practical applicationto quadrilateral, it has been found that its triangulation and traverse surveying algorithms provide better accuracy than trilateration.

  • PDF

A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements (웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구)

  • Lee, Kang-Hwi;Lee, Seong-Su;Kim, Sang-Min;Lee, Hyeok-Jae;Min, Kyoung-Jin;Kang, Hyun-Kyu;Lee, Joo-Hyeon;Kwak, Hwy-Kuen;Ko, Yun-Soo;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.

Parameters of the Magnetic Field Waveform Radiated from Cloud Lightning Discharges (운방전에 의해서 방사된 자장 파형의 파라미터)

  • 이복희;안창환;장석훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.917-926
    • /
    • 1999
  • In this paper, the recording device for measuring the magnetic field waveforms associated with the cloud lightning discharges was made by the loop-type magnetic field sensor, and the measuring system of a distance between lightning stroke point and observatory site was proposed. The parameters including the time interval of superimposed pulses, zero-to-zero crossing time and the percentage depth of the dip for the positive and the negative magnetic field waveforms were statistically analyzed as a function of the distance between the lightning discharge point and the observatory site. The results could be summarized as follows; Several superimposed pulses were observed at the initial front part of the magnetic field waveform produced by cloud lightning discharges, and the mean time interval between superimposed pulses was about $4\mu\textrm{s}$. Also, the bipolar characteristic appeared significantly and the percentage depth of the dip was about 57~65%. It was known that the zero-to-zero crossing time of the electromagnetic fields is gradually decreased as a distance between lightning discharge point and observatory site is increased.

  • PDF

Development of an Impulse Electromagnetic Wave Generator having Rise time of Pico Second (Pico second 기립시간의 충격 전자기파 발생기의 개발)

  • Kim, Young-Bae;Lee, Hong-Sik;Jung, Sun-Shin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.12
    • /
    • pp.597-600
    • /
    • 2006
  • When the energy of the nanoseconds high voltage pulse with hundreds picoseconds of the pulse rise time is emitted into the free space via an antenna, an ultra wide band electromagnetic wave is generated. This electromagnetic wave is expected to be used in transmitting vast amount of informations to far distance, high performance radars, post-packaging pasteurization of food, the detection of underground buried objects, searching of underground water veins or caves, the treatment of waste water or polluted gases and so forth. Additionally, this technology can be used in EMI(electromagnetic interference) evaluation of measuring instruments or printed circuit boards.

The Characteristics of Electromagnetic waves by surface discharge in solid insulator (고체절연체의 연면방전에 따른 방사전자파 분포 특성)

  • Kim, Chung-Hyun;Lee, Hyun-Dong;Kim, Ki-Chai;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In;Lee, Chun-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1862-1864
    • /
    • 2000
  • Recently diagnostic techniques have been investigated to detect a partial discharge(PD) associated with a dielectric material defect in a high-voltage electrical apparatus. Among the PD measuring method, detecting electromagnetic wave generated by PD is one of the most effective method because PD radiates wide frequency of electromagnetic wave up to UHF. From the above points of view, we have investigated the polarization and distance characteristics of electromagnetic wave radiated by an insertion of solid insulators between needle-plane electrodes in the air. According to the magnitude of applied voltage, the frequency spectrum of radiated electromagnetic waves were increased about under 100(MHz), compared with background noise. The electromagnetic wave magnitude is attenuated about 4$\sim$7.6[dB] at the point 3[m] away from PD.

  • PDF

An Analysis of Optimized Position of the Fiber Optic Sensor Istalled near the Bridge Wire of Electro-explosive Device (전기기폭장치의 발열선에 설치되는 광섬유 센서의 최적위치 분석)

  • 김응조;윤기은;최태인;윤태훈;김재창
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1111-1117
    • /
    • 1999
  • In order to measure the temperature of bridge wire, the explosive material is removed from EED and a fiber optic temperature sensor is installed near the bridge wire. Using the heat transfer theory, the optimum position of the fiber optic sensor in the EED is determined and the temperature-distance equation is derived from test result. The measuring technique can be utilized to the real electromagnetic radiation hazard test.

  • PDF

Study on the Positioning Error of Horizontal Point Fixing by Trilateration (수평위치결정(水平位置決定)에 있어서 3변측량(邊測量) 위치오차(位置誤差)에 관한 연구(研究))

  • Yeu, Bock Mo;Lee, Jong Hun;Yoo, Hwan Hee;Chung, Chang Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.3
    • /
    • pp.85-91
    • /
    • 1984
  • This paper is a study on the determination of plane coordinates by observing only the distance with EDM (Electromagnetic Distance Measuring instrument). The advent of EDM has made a precise measurements of long distance be possible, therefore many studies on trilateration were made. It is the object of this study to investigate the error distribution of trilateration according to the changing distance and the geometric figure.

  • PDF

Surface Deformation and Behavior of Magma Activity Using EDM (EDM을 활용한 지표변화율과 마그마 활동 양상 변화 연구)

  • Yun, Sung-Hyo;Lee, Jeong-Hyun
    • The Journal of the Petrological Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.71-81
    • /
    • 2013
  • Measuring the distance between benchmarks placed on a volcano tens to thousands of meters apart can sometimes pinpoint where and when magma is rising toward the surface. Rising magma will sometimes push overlying rocks upward or shove them aside. In either case, one part of the volcano may actually move horizontally relative to another part from as little as a few millimeters to as much as several tens of meters. The challenge in measuring such changes with an electronic distance meter is putting benchmarks in the right places and making frequent measurements between pairs of benchmarks. An electronic distance meter is an instrument that both sends and receives an electromagnetic signal. Depending on the distance between the EDM and reflector, the wavelength of the returned signal will be out of phase with the transmitted signal. The instrument compares the phase of the transmitted and received signals and measures the phase difference electronically. There is a wide range of EDM capabilities in range and precision, but for volcano monitoring purposes, short-range (less than 10 km) to medium-range (less than 50 km) EDM's are typically used. Short-range EDM's transmit and receive the near visible infrared part of the electromagnetic spectrum for measuring distances with an accuracy of about 5 mm.

Simulation Study on Measuring Pulverized Coal Concentration in Power Plant Boiler

  • Chen, Lijun;Wang, Yang;Su, Cheng
    • Journal of Information Processing Systems
    • /
    • v.15 no.1
    • /
    • pp.189-202
    • /
    • 2019
  • During thermal power coal-fired boiler operation, it is very important to detect the pulverized coal concentration in the air pipeline for the boiler combustion stability and economic security. Because the current measurement methods used by power plants are often involved with large measurement errors and unable to monitor the pulverized coal concentration in real-time, a new method is needed. In this paper, a new method based on microwave circular waveguide is presented. High Frequency Electromagnetic Simulation (HFSS) software was used to construct a simulation model for measuring pulverized coal concentration in power plant pipeline. Theoretical analysis and simulation experiments were done to find the effective microwave emission frequency, installation angle, the type of antenna probe, antenna installation distance and other important parameters. Finally, field experiment in Jilin Thermal Power Plant proved that with selected parameters, the measuring device accurately reflected the changes in the concentration of pulverized coal.

A Study on the Electromagnetic Wave Measurement in Diagnostic Imaging Equipment (진단용 영상장치에서 전자파 측정에 관한 고찰)

  • Eo, Yun-Gi
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.39-44
    • /
    • 2005
  • Purpose of this research is that if Radiographer has focused on Radiation exposure research until now, he should realize that always exposed by Electro Magnetic Wave at given working environment And also, another purpose is that to minimize damage with measuring Electro Magnetic Wave which is happened area and distance of Radiation Control System and High Voltage Equipment, check occurrence rate and minimize damage from it.

  • PDF