• 제목/요약/키워드: electromagnetic distance measuring

검색결과 33건 처리시간 0.037초

해안매립을 위한 수평위치 결정에 관한 연구 (A study on horizontal positing for the seashore reclamation)

  • 문두열
    • 한국해양공학회지
    • /
    • 제11권2호
    • /
    • pp.113-121
    • /
    • 1997
  • With the increase use of electromagnrtic distance measuring equiment, is is required that we need to study the higher dimensional applications and detail technical methods. The purpose of this paper is to improve the accuracy of ocean construction surveying and computer programming for determining of horizontal position of a quadrilateral by measuring line on traverse surveyng, trigulation and trilateration. Aa long distance measurements with high accuracy became possible by the apperance of EDM distance measuring instruments, we induced correct adjustment equation through angle condition and area conditionequation. After that we compared and experimental model. From its a result of the practical applicationto quadrilateral, it has been found that its triangulation and traverse surveying algorithms provide better accuracy than trilateration.

  • PDF

웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구 (A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements)

  • 이강휘;이성수;김상민;이혁재;민경진;강현규;이주현;곽휘권;고윤수;이정환
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.

운방전에 의해서 방사된 자장 파형의 파라미터 (Parameters of the Magnetic Field Waveform Radiated from Cloud Lightning Discharges)

  • 이복희;안창환;장석훈
    • 한국전자파학회논문지
    • /
    • 제10권6호
    • /
    • pp.917-926
    • /
    • 1999
  • 본 논문에서는 운방전에 의해서 방사되는 자장 파형을 측정할 수 있는 루프형 자장 센서를 이용한 계측장 치를 제작하고, 뇌방전과 관측점 사이의 거리측정계를 제안하였다. 정극성과 부극성의 자장 파형에 대한 중첩 펄스의 시간 간격, 영점 교차시간과 백분율 반전답의 깊이 등의 파라미터를 뇌방전 지점과 관측 지점 사이의 거리에 따라 통계적으로 분석하였으며, 그 결과를 요약하면 다음과 같다 운방전에 의해서 발생한 자장 파형 의 파두 부분에는 수 개의 중첩 펄스가 관측되었으며, 이들 펄스 사이의 평균 시간 간격은 약 $4\mu\textrm{s}$이었다. 또 한, 양극성 특성이 명확하게 나타났으며, 백분율 반전답의 깊이는 약 57 -65 %이었다. 뇌방전 지점에서 관측 지점 사이의 거리가 증가할수록 영점 교차시간은 짧아졌다.

  • PDF

Pico second 기립시간의 충격 전자기파 발생기의 개발 (Development of an Impulse Electromagnetic Wave Generator having Rise time of Pico Second)

  • 김영배;이홍식;정순신
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.597-600
    • /
    • 2006
  • When the energy of the nanoseconds high voltage pulse with hundreds picoseconds of the pulse rise time is emitted into the free space via an antenna, an ultra wide band electromagnetic wave is generated. This electromagnetic wave is expected to be used in transmitting vast amount of informations to far distance, high performance radars, post-packaging pasteurization of food, the detection of underground buried objects, searching of underground water veins or caves, the treatment of waste water or polluted gases and so forth. Additionally, this technology can be used in EMI(electromagnetic interference) evaluation of measuring instruments or printed circuit boards.

고체절연체의 연면방전에 따른 방사전자파 분포 특성 (The Characteristics of Electromagnetic waves by surface discharge in solid insulator)

  • 김충년;이현동;김기채;박원주;이광식;이동인;이춘하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1862-1864
    • /
    • 2000
  • Recently diagnostic techniques have been investigated to detect a partial discharge(PD) associated with a dielectric material defect in a high-voltage electrical apparatus. Among the PD measuring method, detecting electromagnetic wave generated by PD is one of the most effective method because PD radiates wide frequency of electromagnetic wave up to UHF. From the above points of view, we have investigated the polarization and distance characteristics of electromagnetic wave radiated by an insertion of solid insulators between needle-plane electrodes in the air. According to the magnitude of applied voltage, the frequency spectrum of radiated electromagnetic waves were increased about under 100(MHz), compared with background noise. The electromagnetic wave magnitude is attenuated about 4$\sim$7.6[dB] at the point 3[m] away from PD.

  • PDF

전기기폭장치의 발열선에 설치되는 광섬유 센서의 최적위치 분석 (An Analysis of Optimized Position of the Fiber Optic Sensor Istalled near the Bridge Wire of Electro-explosive Device)

  • 김응조;윤기은;최태인;윤태훈;김재창
    • 한국전자파학회논문지
    • /
    • 제10권7호
    • /
    • pp.1111-1117
    • /
    • 1999
  • EED 내부의 화약을 제거하고 광섬유센서를 발열선에 근접 설치하면 EED의 발열선 온도를 정확하게 측정 할 수 있다 .. EED의 발열 선과 광섬유 센서간의 이격할 수 있는 최적거리 계산을 열전달 이론에 근거하여 구 하였고. 발열선의 온도-이격거리 관계식을 도출하였다. 연구결과는 외부 전자파환경에 의해서 유기된 전류로 인해 발생되는 발열선의 온도를 측정하는 전자파방사 위해도 시험에 활용할 수 있다.

  • PDF

수평위치결정(水平位置決定)에 있어서 3변측량(邊測量) 위치오차(位置誤差)에 관한 연구(研究) (Study on the Positioning Error of Horizontal Point Fixing by Trilateration)

  • 유복모;이종훈;유환희;정창식
    • 대한토목학회논문집
    • /
    • 제4권3호
    • /
    • pp.85-91
    • /
    • 1984
  • 전자파거리측정기의 출현으로 거리의 정밀측정이 가능해지므로써 수평위치결정기법(水平位置決定技法) 중에 한 방법인 3변측량(邊測量)의 연구(硏究)가 본격화(本格化) 되기에 이르렀다. 따라서 본(本) 연구(硏究)에서는 전자파거리측정기에 의하여 변(邊)만을 관측(觀測)하므로써 수평위치결정(水平位置決定)을 하였고 기준점간(基準點聞)의 거리변화에 따른 오차분포(誤差分布)와 기하학적(幾何學的) 조건(條件)을 변화(變化)시켜 미지점(未知點)의 좌표에 미치는 영향을 분석(分析)하여 기준점(基準點)의 최척위치선정에 의의를 두고있다.

  • PDF

EDM을 활용한 지표변화율과 마그마 활동 양상 변화 연구 (Surface Deformation and Behavior of Magma Activity Using EDM)

  • 윤성효;이정현
    • 암석학회지
    • /
    • 제22권1호
    • /
    • pp.71-81
    • /
    • 2013
  • 화산체 위에서 수 km 또는 십 수 km 떨어진 거리에 위치한 수준점 사이의 거리 측정은 때때로 마그마가 지표로 상승할 때, 그 시기와 장소를 정확하게 나타낼 수 있다. 지표로 상승하는 마그마는 그 상부 암층을 상방으로 밀어 올리거나 또는 화산체의 정상부를 옆으로 밀어내기도 하다. 어떤 경우이든 화산체의 특정한 한 지점이 다른 지점에 비교하여 수 mm에서 수 십 m 이상으로 수평으로 움직일 수 있다. 전자거리측정장치인 광파측거의(EDM)를 통한 이러한 변화의 측정에 대한 시도는 적절한 장소에서 수준점들을 설정하고 이들 수준점들을 짝을 이루어 수시로 측정하는 것이다. 광파측거의는 전자기파 신호를 보내고 수신하는 장비이다. 광파측거의와 반사경 사이의 거리에 따라 되돌아오는 신호의 주파수는 전송된 신호와 위상차를 나타낼 것이다. 전송된 신호와 수신된 신호의 위상을 비교하여 전자적으로 위상차로부터 거리를 측정한다. 측정범위와 정밀도에 따라 광파측거의의 종류는 다양하다. 화산모니터링의 목적으로 단거리(10 km 이내) 광파측거의와 중거리(50 km 이내) 광파측거의가 일반적으로 사용되고 있다. 단거리 광파측거의는 전자기 스펙트럼의 가시 적외선에 가까운 영역을 전송하고 수신하면서 5 mm 이내의 정확도를 가지고 있다. 본 연구에서는 지금까지 알려진 광파측거의의 특성과 작동 원리, 국외 화산지역의 지표 변화율 측정 실례를 알아보고, 백두산에서의 지표면 변형 측정에 활용 가능한 기법을 기술하였다.

Simulation Study on Measuring Pulverized Coal Concentration in Power Plant Boiler

  • Chen, Lijun;Wang, Yang;Su, Cheng
    • Journal of Information Processing Systems
    • /
    • 제15권1호
    • /
    • pp.189-202
    • /
    • 2019
  • During thermal power coal-fired boiler operation, it is very important to detect the pulverized coal concentration in the air pipeline for the boiler combustion stability and economic security. Because the current measurement methods used by power plants are often involved with large measurement errors and unable to monitor the pulverized coal concentration in real-time, a new method is needed. In this paper, a new method based on microwave circular waveguide is presented. High Frequency Electromagnetic Simulation (HFSS) software was used to construct a simulation model for measuring pulverized coal concentration in power plant pipeline. Theoretical analysis and simulation experiments were done to find the effective microwave emission frequency, installation angle, the type of antenna probe, antenna installation distance and other important parameters. Finally, field experiment in Jilin Thermal Power Plant proved that with selected parameters, the measuring device accurately reflected the changes in the concentration of pulverized coal.

진단용 영상장치에서 전자파 측정에 관한 고찰 (A Study on the Electromagnetic Wave Measurement in Diagnostic Imaging Equipment)

  • 어윤기
    • 대한디지털의료영상학회논문지
    • /
    • 제7권1호
    • /
    • pp.39-44
    • /
    • 2005
  • Purpose of this research is that if Radiographer has focused on Radiation exposure research until now, he should realize that always exposed by Electro Magnetic Wave at given working environment And also, another purpose is that to minimize damage with measuring Electro Magnetic Wave which is happened area and distance of Radiation Control System and High Voltage Equipment, check occurrence rate and minimize damage from it.

  • PDF