• Title/Summary/Keyword: electrode length

Search Result 332, Processing Time 0.028 seconds

Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode (선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

Ozone Generation Characteristics by Surface-Silent Discharge According to the Length of Coaxial Electrode (동축형 전극길이 변화시의 연면무성방전에 의한 오존발생특성(I))

  • Jo, Guk-Hui;Kim, Yeong-Bae;Seo, Gil-Su;Lee, Hyeong-Ho;Lee, Sang-Geun;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.791-797
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects of ozone. In this paper the concentration, yield and generation quantity of the ozone by the Surface-Silent Discharge According to the Length of Coaxial Electrode is described. The electrodes composed of 3 electrodes-2 gaps are coaxial type and the ozone generation tube were designed and fabricated from the point of view of the energy efficiency, stability and easy control. To investigate the ozone generation dependency on electrode length, a few discharge tubes with different lengths were fabricated. The experimental equipments were provided with cooling system and dehumidifier for the many testing conditions. The main results show that the concentration, yield and generation quantity of ozone are improved by decreasing gas temperatures and increasing electrode lengths.

  • PDF

Flashover Characteristics of Air in the Arrangement of Cylinder-Shaped Rod and Plane Electrode in Case of Flame on the Plane Electrode (평단봉대평판 전극배치에서 평판 전극에 화염이 존재할 때 공기의 섬락전압 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.82-87
    • /
    • 2012
  • In this paper, flashover characteristics of air in the vertical arrangement of cylinder-shaped rod and plane gap in the case of combustion flame on the plane electrode were examined under the application of a.c. and d.c. high-voltages. In order to investigate the effect of propane flame on the flashover characteristics of air, flashover voltages in accordance with the variation of the gap length and the horizontal distance between the flame and the high-voltage rod electrode were measured. As the result of the experiment, flashover voltages in the presence of the flame were substantially lowered than those in the absence of flame, and the polarity effects with the d.c. voltages on appeared owing to the flame. Flashover voltages of air were increased in the proportion of the gap length and the horizontal distance in the case of both a.c. and d.c. voltages, but the flame was extinguished by such corona wind that was produced from the rod electrode when the gap length and the horizontal distance reached to a certain degree.

Correlation Analysis of the Dielectric Breakdown Voltage of Liquid Nitrogen (액체질소 절연파괴전압의 상관 분석)

  • Baek, Seung-Myeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.396-399
    • /
    • 2015
  • We analyzed the correlation between breakdown voltage(BDV) of liquid nitrogen(LN2) and factors. The chosen factors affecting the breakdown are the diameter of electrode, gap length, temperature of LN2, and pressure of LN2. The BDV of LN2 was increased with increasing the diameter, the gap length and the pressure. And The BDV of LN2 was increased with decreasing the temperature. However, correlation coefficient was different from each other depending on the situation. The BDV exhibited a very high correlation coefficient of 0.92227 to dependence on the diameter. And a very high correlation coefficient of 0.94980 to dependence on the pressure under sphere(D 7.5 mm)-plane electrode. When the pressure is applied, sphere-plane electrode is the correlation coefficient was higher than that of the needle-plane electrode. It shows the dependence of a temperature coefficient of -0.758290 ~ -0.39946 under needle-plane electrode.

Computation of the Critical Lengths of the Vertical Grounding Electrode in Multi-Layered Soil Structures (다층 대지구조에서 수직 접지전극의 임계길이 산정)

  • Kim, Ki-Bok;Joe, Jeong-Hyeon;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The grounding impedance is not lowered by expanding the dimension of the grounding electrode, and the length of grounding electrode which shows the minimum value of the grounding impedance for each condition of frequency and soil characteristics is existent, and it is defined as Critical Length. In this paper, a new distributed parameter circuit model considering the condition of the multi-layered soil structures was proposed, and the grounding impedance and critical length of the vertical grounding electrode were analyzed by using the newly proposed simulation model and the MATLAB program. As a consequence, it was found that the effect of the soil structure on the frequency-dependent grounding impedance and critical length of the vertical grounding electrode is significant. It is desirable to consider the soil structure in optimal design of the grounding system.

A Study on the Influence of Coaxial Parallel Magnetic Field upon Plasma Jet (Plasma Jet의 동축평행 자계에 의한 영향에 관한 연구 ( 1 ))

  • 전춘생
    • 전기의세계
    • /
    • v.22 no.2
    • /
    • pp.57-69
    • /
    • 1973
  • The aim of this study was to investigate the behaviors of plasma jet under coaxial magnetic field in paralled with it for controlling optical characteristics and input power of plasma jet without impurity and instability of arc plasma column. Because the discharge characteristics of plasma jet were so distinctively different according to the existence or non-existence of magnetic field, the input power, luminous intensity of plasma jet and thermal efficiency were comparatively studied in respect of such variables as arc current, gap of electrode, quantity of argon flow, magnetic flux density, diameter and length of nozzle, with the use of several materials which were different in diameter and length of nozzel. The results were as follows; 1) The voltage tends to show a drooping characteristic at law current and then rises gradually. The luminous intensity of plasma jet increases exponentially with arc current. 2) Arc voltage increases and luminous intensity tends to decrease gradually as gap of electrode increases. 3) Arc voltage and luminous intensity tends to decrease gradually as gap of electrode increases. 3) Arc voltage and luminous intensity increase in accordance with the quantity of argon flow. 4) At first step, arc voltage increases to maximum value with the growth of flux density and then tends to show a gradual decrease. Luminous intensity decreases with the growth flux density. 5) Arc voltage decreases as the constriction length of nozzle increases, maximum decrease is shown at the constriction length of 20(mm) and it increases beyond that value. The luminous intensity decreases as the constriction length grows. 6) Arc voltage and luminous in tensity increase with the growth of diameters of nozzle. 7) Thermal efficiency has values between 50% and 75%, being influenced by arc current, the quantity of argon flow, flux density, the length of electrode gap and the constriction length of nozzle.

  • PDF

Minimized Distance of the Current Electrode in the Measurement of Ground Resistance (접지저항 측정에 있어서 전류전극의 최소 이격거리)

  • Lee, Sang-Mu;Kang, Young-Heung;Yang, Jun-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.68-73
    • /
    • 2006
  • As in the measurement of ground resistance by using the 3 point fall-of-potential method, it is known that the distance of current electrode should be at the point of showing the plateu on the potential curve. But the problem is that it my be practically impossible to meet the condition in actual sites. For solving such a situation, this paper provides the least distance of current electrode according to the analysis for the test-field measurement showing that it is feasible to measure the ground resistance in the two in current electrode distance as the length of driven-rod type electrode and the some district length of mesh electrode.

The Study on the Optimal Transmission Efficiency Characteristics of Pulse Energy Using Magnetic Pulse Compressors (가포화 자기스위치 MPC를 적용한 저온 플라즈마의 펄스에너지 전송효율 특성)

  • 이유수;정종한;정현주;김문환;김희제
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.383-387
    • /
    • 2003
  • In this paper, we have studied about optimal transmission efficiency characteristics of pulse energy in a coal plant for removing environmental polluted gas. The electrical efficiency of pulse power systems depends on impedance of the reactor. To obtain high efficiency, we used MPC(Magnetic pulse compressor) as the power switch and tested their characteristics as electrode length of the reactor and charging voltage of capacitor, As results, we obtained a compressed pulse such as pulse voltage of 10㎸, rising time 200ns and pulse width of 500ns. With increasing electrode length, the load impedance was decreased but the electrical efficiency was increased.

A Study on the Characteristics of Corona Critical Voltage and EMTP Simulatuon on Increasing Load Impedance and Pulse Repetition (전극길이 및 펄스반복율에 대한 부하임피던스 특성변화 및 EMTP 해석에 관한 연구)

  • Joung, Jong-Han;Song, Woo-Jung;Jeon, Jin-An;Lee, U-Soo;Kim, Hwi-Young;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1850-1852
    • /
    • 2002
  • In this paper, we studies EMTP analysis and characteristics of critical voltage of pulse corona and load impedance on variable electrode length. To obtain a stable Pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a result, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

  • PDF

A Study on the Characteristics of Corona Critical Voltage on Increasing Load Impedance (전극길이 및 펄스반복율에 대한 부하임피던스 특성변화에 관한 연구)

  • Joung, Jong-Han;Song, Woo-Jung;Jeon, Jin-An;Lee, U-Soo;Kim, Hwi-Young;Kim, Hee-Je
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.184-186
    • /
    • 2002
  • In this paper, we studies EMTP analysis and characteristics of critical voltage of pulse corona and load impedance on variable electrode length. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a result, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

  • PDF