• Title/Summary/Keyword: electrode length

Search Result 333, Processing Time 0.027 seconds

Electrostatic Suspension and Transportation Device of Glass Panels (정전기력을 이용한 유리 판넬의 비접촉 지지 및 반송)

  • Jeon Jong-Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.76-85
    • /
    • 2006
  • In the manufacture of liquid crystal display devices, there is a strong demand for contactless glass panel handling devices that can manipulate a glass panel without contaminating or damaging it. To fulfill this requirement, an electrostatic transportation device for glass panels is proposed. This device can directly drive a glass panel and simultaneously provide contactless suspension by electrostatic forces. To accomplish these two functions, a feedback control strategy and the operational principle of an electrostatic induction motor are utilized. The stator possesses electrodes which exert electrostatic farces on the glass panel and are divided into a part responsible for suspension and one for transportation. To accomplish dynamic stability and a relatively fast suspension initiation time, the structure of the electrode for suspension possesses many boundaries over which potential differences are formed. In this paper, an electrode pattern suitable for the suspension of glass panels is described, followed by the structure of the transportation device and its operational principle. Experimental results show that the glass panel has been transported with a speed of approximately 25.6 mm/s while being suspended stably at a gap length of 0.3 mm.

Characteristics of a Corona between a Wiring Clamp(Dead End Clamp) and a Porcelain Insulator Used in a 154[kV] Power Receptacle

  • Han, Un-Ki;Kim, Jong-Min;Bang, Sun-Bae;Kim, Han-Sang;Choi, Hyeong-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.57-63
    • /
    • 2007
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154[kV] dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in 154[kV] power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method(FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

Effects of Stimulation Conditions and Waveforms on Muscle Contractile Characteristics

  • Song Tongjin;Khang Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.111-116
    • /
    • 2005
  • This study was designed to apply the stimulation system developed in our laboratory to investigate how the stimulation conditions affect the muscle contractile characteristics in the isometric condition as well as during the FES standing/walking. Four paraplegic and ten healthy subjects participated in this study, and their knee extensors were voluntary contracted or electrically stimulated to measure the muscle force and the fatigue index for different waveforms of the pulse train. We also investigated different combinations of the electrode positions during standing/walking. It was confirmed that continuous and high-frequency stimulation causes faster fatigue than intermittent and low-frequency stimulation. Fatigue resistance was higher around the optimal muscle length than at a stretched position in healthy subjects, whereas the opposite was observed in paralyzed subjects. The paired t-test results with the level of significance at 0.01 indicated that the sinusoidal waveform generated the largest torque among the four typical waveforms. Although statistically not very significant, the sinusoidal waveform also generated, in general, the highest fatigue resistance at an intensity level below the supramaximal stimulation. One of the paraplegic subject who participated in the standing/walking program can now stand up for 1 minute and 50 seconds with the knee extensors, and walk for about 5 minutes at the speed of 12m/sec.

The Frequence Band on the Pizoelectric Characteristic of the Piezoelectric Ceramic Filter (압전 세라믹 필터의 압전 특성에 의한 대역폭 의존성에 관한 연구)

  • Lee, S.H.;Seok, J.Y.;Ha, S.J.;Ryu, G.H.;Kim, H.G.;Yoo, J.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.613-617
    • /
    • 2002
  • The ceramic filters were developed using technology similar to that of quartz crystal and electromechanical filter. However, the key to this development involved the theoretical analysis of vibration modes and material improvements of piezoelectric ceramics. The primary application of ceramic filters has been for consumer-market use. Accordingly, a major emhpasis has involved mass production technology, leading to low-priced devices. A typical ceramic filter includes monolithic resonators and capacitors packaged in unique configurations. Nakazawa developed a double-mode resonator as two acoustically coupled single resonators. And he developed 10.7MHz crystal filters using multi-energy trapping mode of thickness shear vibration. He succeeded in realizing a two-pole band pass filter response without external inductance by splitting a dot electrode to creat coupled symmetric and antisymmetric vibration modes. Accordingly, the simulation for ceramic filter were important. So that, this paper were investigated the pass frequency of filter on the electrode length and thickness of ceramic.

  • PDF

Nano-Scale Cu Direct Bonding Technology Using Ultra-High Density, Fine Size Cu Nano-Pillar (CNP) for Exascale 2.5D/3D Integrated System

  • Lee, Kang-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.69-77
    • /
    • 2016
  • We propose nano-scale Cu direct bonding technology using ultra-high density Cu nano-pillar (CNP) with for high stacking yield exascale 2.5D/3D integration. We clarified the joining mechanism of nano-scale Cu direct bonding using CNP. Nano-scale Cu pillar easily bond with Cu electrode by re-crystallization of CNP due to the solid phase diffusion and by morphology change of CNP to minimize interfacial energy at relatively lower temperature and pressure compared to conventional micro-scale Cu direct bonding. We confirmed for the first time that 4.3 million electrodes per die are successfully connected in series with the joining yield of 100%. The joining resistance of CNP bundle with $80{\mu}m$ height is around 30 m for each pair of $10{\mu}m$ dia. electrode. Capacitance value of CNP bundle with $3{\mu}m$ length and $80{\mu}m$ height is around 0.6fF. Eye-diagram pattern shows no degradation even at 10Gbps data rate after the lamination of anisotropic conductive film.

Template Synthesis of Nitrogen-Doped Short Tubular Carbons with Big Inner Diameter and their Application in Electrochemical Sensing

  • Cheng, Rui;Zou, Qiong;Zhang, Xiaohua;Xiao, Chunhui;Sun, Longfei;Chen, Jinhua
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2423-2430
    • /
    • 2014
  • Nitrogen-doped short tubular carbons (N-STCs) with big inner diameter have been successfully synthesized via carbonization of polydopamine (PDA) wrapped halloysite nanotubes (HNTs). The obtained N-STCs have average length of $0.3{\mu}m$ with big inner diameter (50 nm), thin wall (2-3 nm) and large surface area ($776m^2g^{-1}$), and show excellent electrochemical properties. As an example in electrochemical applications, N-STCs were used to electrochemically detect hydrogen peroxide ($H_2O_2$) and glucose. The results showed that the N-STCs modified glassy carbon (N-STCs/GC) electrode had much better analytical performance (lower detection limit and wider linear range) compared to the acid-treated carbon nanotubes (AO-CNTs) based GC electrode. The unique structure endows N-STCs the enhanced electrochemical performance and promising applications in electrochemical sensing.

Study on the Dielectric Characteristics of Gaseous Nitrogen for Designing a High Voltage Superconducting Fault Current Limiter

  • Heo, Jeong-Il;Hong, Jong-Gi;Nam, Seok-Ho;Kang, Hyoung-Ku
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.2
    • /
    • pp.28-31
    • /
    • 2012
  • The study on the dielectric characteristics of gaseous insulation medium is important for designing current leads of superconducting machines using a sub-cooled liquid nitrogen ($LN_2$) cooling method. In a sub-cooled $LN_2$ cooling system, the temperature of gaseous insulation medium surrounding current leads varies from the temperature of coolant to 300 K according to the displacement between the electrode system and the surface of sub-cooled $LN_2$. In this paper, AC withstand voltage experiments on gaseous nitrogen according to temperature are conducted. Also, AC withstand voltage experiments on gaseous nitrogen according to pressure, size of electrode, and gap length between two electrodes are performed. It is found that there is a functional relation between the electrical breakdown voltage and the field utilization factor (${\xi}$). As a result, the empirical formula for estimating an electrical breakdown voltage is deduced by adopting the concept of field utilization factors. It is expected that the experimental results presented in this paper are helpful to design current leads for a high voltage superconducting apparatus such as a superconducting fault current limiter (SFCL) using a sub-cooled $LN_2$ cooling system.

The Design Simulation for Manufacture of High Frequence Ceramic Filter (고주파용 세라믹 필터의 제작을 위한 디자인 해석)

  • Lee, S.H.;Seok, J.Y.;Ryu, G.H.;SaGong, G.;Yoon, K.H.;Yoo, J.H.;Park, C.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.418-421
    • /
    • 2001
  • The ceramic filters were developed using technology similar to that of quartz crystal and electromechanical filter. However, the key to this development involved the theoretical analysis of vibration modes and material improvements of piezoelectric ceramics. The primary application of ceramic filters has been for consumer-market use. Accordingly, a major emhpasis has involved mass production technology, leading to low-priced devices. A typical ceramic filter includes monolithic resonators and capacitors packaged in unique configurations. Nakazawa developed a double-mode resonator as two acoustically coupled single resonators. And he developed 10.7MHz crystal filters using multi-energy trapping mode of thickness shear vibration. He succeeded in realizing a two-pole band pass filter response without external inductance by splitting a dot electrode to creat coupled symmetric and antisymmetric vibration modes. Accordingly, the simulation for ceramic filter were important. So that, this paper were investigated the pass frequency of filter on the electrode length and thickness of ceramic.

  • PDF

Characteristics and Fabrication of a Waveguide Type $Ti:LiNbO_3$(Acousto-Optic Tunable Filter) for Optical Communications (광통신용 도파로형 $Ti:LiNbO_3$ AOTF 제작 및 특성)

  • 김성구;한상필;윤형도;임영민;윤대원;정운조;박계춘;정해덕
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.8
    • /
    • pp.637-645
    • /
    • 1998
  • The characteristics of waveguide, electrode and packaging fabricated for acousto-optic tunable filters(AOTF) used for optical communications were analyzed. A $Ti:LiNbO_3$in-diffusing method was employed for the formation of the optical waveguide with a dimension of width $8{\mu}m$, length $30000-50000{\mu}m$ and varying the thickness. The diffusion was carried at $1050^{\circ}C$ for 8 hours to pattern the optical waveguide. The resulted waveguide exhibited a single mode at 1550nm optical wavelength. The width of IDT, with 10 SAM periods, was $5000{\mu}m$ . Impedances of the electrodes deposited with Au were analyzed using a network analyzer; $48.1\Omega$ at the center frequency of 193MHz for electrode thickness of $1500{\AA}$ and $50.7\Omega$ at the center frequency of 192MHz for $1600\AA$. And the characteristics of packaged AOTF was analyzed. When the electrical frequency 177.1MHz was applied to the device, the mode conversion efficiency was measured as 63% at the optical wavelength 1515nm.

  • PDF

Electrical Properties Associated with Discharge Developments in Water Subjected to Impulse Voltages

  • Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.156-162
    • /
    • 2010
  • This paper describes electrical and optical characteristics of discharge developments in water under inhomogeneous fields caused by impulse voltages. Predischarge current and discharge light images were observed for different water resistivities and applied voltages between the hemispherical water tank and the needle electrode. The electrical parameters characterizing discharge developments are analyzed based on the discharge light images and voltage-current (V-I) curves, and electrical resistances derived by voltage and current waveforms. As a result, when the streamer corona is initiated at the tip of the needle electrode, the transient resistance suddenly drops and V-I curves form a 'loop'. The length of streamer propagation is increased with increasing peak value of the applied voltage, and the streamer corona extension is enlarged with increasing water resistivity. The electrical resistances before streamer corona initiation are rarely changed by different applied voltages. On the other hand, the electrical resistances after streamer corona initiation are found to be inversely proportional to the peak value of the applied voltage, and the decreasing rates for higher water resistivities are much higher than those for lower water resistivities. The time to streamer corona initiation and the time to the second current peak become shorter as the voltage increases. Finally, the calculated resistances after streamer corona initiation are almost the same trace of measured resistances, but they are smaller than the measured values.