• 제목/요약/키워드: electrochemical biosensor

검색결과 129건 처리시간 0.026초

Electrochemical Diagnosis of Magnesium Ion in Fish Liver and Mice Droppings

  • Lee, Chang-Hyun;Ly, Suw Young
    • 한국응용과학기술학회지
    • /
    • 제31권4호
    • /
    • pp.663-668
    • /
    • 2014
  • An in-vivo diagnosis of trace Mg(II) ion was performed using a low-cost and environment-friendly voltammetric method, using a graphite counter and reference electrodes and a fluorine-immobilized graphite working electrode, and clean deep seawater was used as an electrolyte solution. Under optimum conditions, the analytical working ranges attained microgram ranges, and a detection limit of $80.6ugL^{-1}$ was obtained using stripping voltammety with 60 sec accumulation time. Ex-vivo application was performed on fish liver and mice droppings. The developed techniques can be applicable to tumor cell analysis.

이식형 혈당 센서의 생리활성 물질에 의한 방해 효과를 제거하기 위한 새로운 효소고정법 개발 (Development of Enzyme Immobilization Method to Remove Interference by Physiological Chemicals for Implantable Glucose Sensors)

  • 정택동;김희찬
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.72-73
    • /
    • 1998
  • A new method for enzyme immobilization has been developed to remove interference by potential interferents in body fluids. Instead of using electron mediators, we chose direct hydrogen peroxide measurement route. Extremely hydrogen peroxide-selective polymer was coated as an inner membrane to exclude interferents and then glucose oxidase(GOx) was entrapped by electropolymerization of inert monomers. There was no solvent casting step throughout the whole fabrication procedure but all membranes on Pt-Ir electrode were formed by electropolymerization. Thus, membrane thickness, quantity of enzyme loaded and can be controlled by electrochemical parameters. As a result, reproducibility of biosensor characteristics becomes remarkably improved in terms of mass production.

  • PDF

Electrochemical Assay of Neurotransmitter Glycine in Brain Cells

  • Ly, Suw-Young;Kim, Dong-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.515-519
    • /
    • 2007
  • Neurotransmitter glycine in the nano gram range was analyzed using a paste electrode (PE) in cyclic voltammetry (CV) and square-wave stripping voltammetry (SWSV). An anodic peak caused by oxidation of the glycine ion appeared at the 0.4 V (versus Ag/AgCl/KCl) potential in a 0.1 M NH4H2PO4 electrolyte solution. At optimized conditions, the working range of the SWSV and CV concentration was found to be 5-60 ngL-1 glycine; precision of R2 = 0.9816 (SWSV) and 0.9986 (CV); and detection limit of 0.65 ngL-1 (5.82 × 10-12 molL-1) (S/N = 3). The optimized conditions were applied to an assay in a fish brain tissue and a living brain cell in real time.

Fabrication and Characterization of Silole and Biotin-functionalized Rugate Porous Silicon

  • 권형준
    • 통합자연과학논문집
    • /
    • 제3권1호
    • /
    • pp.24-27
    • /
    • 2010
  • Multi-functionalized rugate porous silicon (PSi) for biosensor was developed by hydrosilylation with silole and its further reaction with biotin groups. PSi was generated by an electrochemical etching of silicon wafer in aqueous ethanolic HF solution PSi prepared by using etching conditions showed that many sharp spectral lines can be obtained in the optical reflectivity spectrum. 1,1-hydrovinyl-2,3,4,5-tetraphenylsilole was obtained from the reaction of 1,1-dilithio-2,3,4,5-tetraphenyl-1,3-butadiene with dichlorovinylsilane. Multi-functionalized PSi with silole and biotin groups was characterized by UV-vis absorption spectroscopy, Ocean optics 2000 spectrometer, and fluorescence spectroscopy. Optical characteristics such as reflectivity and photoluminescence (PL) were observed. An increase of the reflection wavelength in the reflectivity spectrum by 20 nm was observed, indicative of a change in refractive indices induced by hydrosilylation of the silole and biotin groups to the rugate PSi. This red-shift was attributed to the replacement of some of the Si-H group of fresh rugate PSi with silole and biotin group.

바이오센서 (Biosensors)

  • 김의락
    • KSBB Journal
    • /
    • 제15권5호
    • /
    • pp.423-427
    • /
    • 2000
  • 바이오센서의 구조와 기능 그리고 종류에 대해 소개하였다. 이 분야의 연구가 과거 15년간 각국에서 경쟁적으로 연 구하였으나 glucose sensor가 상품화되 었을 뿐 연구결과를 상 품화한 것은 극히 적은 수였다. 그러나 최근 몇 년간 특히 포켓용 i-STAT point-of-care system의 도입 그리고 surface plasmon resonance와 evanescent wave 측정 장치 의 출현으로 상품화된 바이오샌서의 수가 크게 증가하는 추세에 었다. 이들 중 의료임상과 생물공정 그리고 환경오염 측정용으로 응 용되고 있는 몇 가지 상품에 대하여 약술하였다.

  • PDF

자기력과 self-assembly에 의한 3차원 바이오칩의 개발 (Development of 3-Dimensional Biochip Using Magnetic Interaction and Self-Assembly)

  • 최용성;박대희;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1909-1911
    • /
    • 2003
  • This research describes a new constructing method of multifunctional biosensor using many kinds of biomaterials. A metal particle and an array was fabricated by photolithographic. Biomaterials were immobilized on the metal particle. The array and the particles were mixed in a buffer solution, and were arranged by magnetic force interaction and self-assembly. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost with Au surface on top. The particles were successfully arranged on the array. The biomaterial activities were detected by chemiluminescence and electrochemical methods.

  • PDF

나노입자 효소를 이용한 포도당 검출용 바이오센서의 전기화학적 특성 (Electrochemical Characteristics of Biosensor using Protected Enzyme Nanoparticles for the Detection of Glucose)

  • 이금주;윤동화;장준형;홍석인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1536-1537
    • /
    • 2007
  • 본 논문은 당뇨병의 지표 물질인 glucose의 농도를 극미량의 시료를 사용하여 정량할 수 있는 방법을 개발하기 위해 organic/inorganic 네트웍에 의해 안정화된 나노입자 효소를 이용하여 초소형 효소 전극을 개발하였다. 전극은 실리콘 웨이퍼상에 반도체 공정을 이용하여 마이크로 크기의 금 박막 전극을 제작하였다, Organic/Inorganic 물질과 함께 합성된 glucose oxidase 나노입자는 20nm 크기로 투과형 전자현미경 (Transmission Electron Microscope:TEM)으로 관찰하고, 푸리에변환 적외선분광법(Fourier transform infrared spectrophotometer : FTIR) 을 이용하여 분석하였고, 전극 특성을 알아보기 위해 Potentiostat/Galvanostat을 사용하여 전기 화학 실험을 하였다. 제작된 전극은 시간대 전류법으로 glucose의 농도에 따른 감도를 측정하였다. 실험결과에 따라 전극의 표면에서 발생하는 전류는 glucose의 농도에 비례함을 알 수 있었다. 또한 순환 전압전류법을 통하여 감도를 측정하였다.

  • PDF

자기력에 의한 단백질칩 (Protein Chip Using Magnetic Force)

  • 최용성;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.386-387
    • /
    • 2006
  • This research describes a new constructing method of multifunctional biosensor using many kinds of biomaterials. A metal particle and an array was fabricated by photolithographic. Biomaterials were immobilized on the metal particle. The array and the particles were mixed in a buffer solution, and were arranged by magnetic force interaction and self-assembly. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost with Au surface on top. The particles were successfully arranged on the array. The biomaterial activities were detected by chemiluminescence and electrochemical methods.

  • PDF

Amperometric Biosensor for Urea

  • 하광수;서무룡
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권11호
    • /
    • pp.1149-1152
    • /
    • 1997
  • An enzyme electrode for the amperometric measurement of urea was prepared by co-immobilizing L-glutamate dehydrogenase and urease onto an Immobilon-AV affinity membrane attached to a glassy carbon electrode. The reduced nicotinamide adenine dinucleotide(NADH) was used as the electroactive species. The electrochemical oxidation of NADH was monitored at +1.0 volt vs. Ag/AgCl. The enzyme-immobilized electrode was linear over the range of 2.0 × 10-5 to 2 × 10-4 M. The response time of the electrode was approximately 3 min. and the optimum pH of the enzyme immobilized membrane was pH 7.4-7.6 (Dulbcco's buffer solution). It was stable for at least two weeks or 50 assays. There was no interference from other physiological species, except from high levels of ascorbic acid.

Cell-SELEX Based Identification of an RNA Aptamer for Escherichia coli and Its Use in Various Detection Formats

  • Dua, Pooja;Ren, Shuo;Lee, Sang Wook;Kim, Joon-Ki;Shin, Hye-su;Jeong, OK-Chan;Kim, Soyoun;Lee, Dong-Ki
    • Molecules and Cells
    • /
    • 제39권11호
    • /
    • pp.807-813
    • /
    • 2016
  • Escherichia coli are important indicator organisms, used routinely for the monitoring of water and food safety. For quick, sensitive and real-time detection of E. coli we developed a 2'F modified RNA aptamer Ec3, by Cell-SELEX. The 31 nucleotide truncated Ec3 demonstrated improved binding and low nano-molar affinity to E. coli. The aptamer developed by us out-performs the commercial antibody and aptamer used for E. coli detection. Ec3(31) aptamer based E. coli detection was done using three different detection formats and the assay sensitivities were determined. Conventional Ec3(31)-biotin-streptavidin magnetic separation could detect E. coli with a limit of detection of $1.3{\times}10^6CFU/ml$. Although, optical analytic technique, biolayer interferometry, did not improve the sensitivity of detection for whole cells, a very significant improvement in the detection was seen with the E. coli cell lysate ($5{\times}10^4CFU/ml$). Finally we developed Electrochemical Impedance Spectroscopy (EIS) gap capacitance biosensor that has detection limits of $2{\times}10^4CFU/mL$ of E. coli cells, without any labeling and signal amplification techniques. We believe that our developed method can step towards more complex and real sample application.