• Title/Summary/Keyword: electrochemical biosensor

Search Result 129, Processing Time 0.023 seconds

Fabrication of enzymatic biosensor based on the poly(3-thiophenecarboxylic acid-co-thiophene) polymer as electron-transfer materials

  • Kim, Soo-Yeoun;Jo, Hyeon-Jin;Choi, Seong-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.269-278
    • /
    • 2019
  • We fabricated glucose oxidase (GOx)-modified biosensor for detection of glucose by physical immobilization of GOx after electrochemical polymerization of the conductive mixture monomers of the 3-thiophenecarboxylic acid (TCA) and thiophene (Th) onto ITO electrode in this study. We confirmed the successfully fabrication of GOx-modified biosensor via FT-IR spectroscopy, SEM, contact angle, and cyclic voltammetry. The fabricated biosensor has the detection limit of $0.1{\mu}M$, the linearity of 0.001-27 mM, and sensitivity of $38.75mAM^{-1}cm^{-2}$, respectively. The fabricated biosensor exhibits high interference effects to dopamine, ascorbic acid, and L-cysteine, respectively. From these results, the fabricated GOx-modified biosensor with long linearity and high sensitivity could be used as glucose sensor in human blood sample.

Understanding of the Working Principle of Field-effect Transistor (FET) Biosensor with the Review Of Experimental Measurement Set-up (전계효과트랜지스터(FET) 바이오센서 실험 셋업 분석을 통한 동작원리 이해)

  • Kook-Nyung Lee
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.487-495
    • /
    • 2023
  • Over the past few decades, considerable research has been conducted on field-effect transistor (FET) biosensors; however, other than electrochemical sensors for pH, they have not reached the commercialization stage and still remain at the basic research level. Although several reports have been published on experiments with real biological samples, no reports exist of developments that have reached commercialization or finalized approval for use. In this paper, we explain the reason for the experiments of FET biosensors to induce spurious signals in an experimental setup and explain the existence of misunderstandings regarding the operating principle of FET biosensors owing to the spurious signals. Based on the thoughtful review of the results of previously published papers, we show that the electrochemical read-out principle of FET biosensors requires our intensive understanding of the interfacial potential between the solution and the sensor electrode for further progress in the FET biosensor research.

Fabrication of Polyimide Film Electrode by Laser Ablation and Application for Electrochemical Glucose Biosensor (Laser ablation을 이용한 폴리이미드 필름 전극제조 및 전기화학적 글루코오즈 바이오센서 응용)

  • Park, Deog-Su
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.357-363
    • /
    • 2013
  • An ultraviolet pulsed laser ablation of polyimide film coated with platinum has been used to enhance the sensitivity for the application as an electrochemical biosensor. Densely packed cones are formed on polyimide surface after UV irradiation which results in increase of surface area. In order to apply the sensitivity improvement of laser ablated polyimide film electrodes, the glucose oxidase modified biosensor was fabricated by using an encapsulation in the gel matrix through sol-gel transition of tetraethoxysliane on the surface of laser ablated polyimide film. The optimum conditions for glucose determination have been characterized with respect to the applied potential and pH. The linear range and detection limit of glucose detection were from 2.0 mM to 18.0 mM and 0.18 mM, respectively. The sensitivity of glucose biosensors fabricated with laser ablated polyimide film is about three times higher than that of plain polyimide film due to increase in surface area by laser ablation.

Electrochemical Detection of Self-Assembled Viologen Modified Electrode as Mediator of Glucose Sensor

  • Lee, Dong-Yun;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.106-110
    • /
    • 2009
  • An amperometric glucose biosensor has been developed using viologen derivatives as a charge transfer mediator between a glucose oxidase (GOD) and a gold electrode. A highly stable self-assembled monolayer (SAM) of thiol-based viologen was immobilized onto the gold electrode of a quartz crystal microbalance (QCM) and GOD was immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of -300mV. Upon immobilization of the glucose oxidase onto the viologen modified electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance, such as pH potential, were optimized and assessed. This biosensor offered excellent electrochemical responses for glucose concentration below ${\mu}$ mol level with high sensitivity and selectivity and short response time. The levels of the RSDs (<5%) for the entire analyses reflected the highly reproducible sensor performance. A linear calibration range between the current and the glucose concentration was obtained up to $4.5{\times}10^{-4}M$. The detection limit was determined to be $3.0{\times}10^{-6}M$.

Improved Sensitivity of a Glucose Sensor by Encapsulation of Free GOx in Conducting Polymer Micropillar Structure

  • Jung, Shin-Hwan;Lee, Young-Kwan;Son, Yong-Keun
    • Journal of Electrochemical Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.124-129
    • /
    • 2011
  • A simple process of fabricating micropillar structure and its influence upon enhancing electrochemical biosensor response were studied in this work. Conducting polymer PEDOT was used as a base material in formulating a composite with PVA. Micro porous PC membrane filter was used as a template for the micropillar of the composite on ITO electrode. This structure could provide plenty of encapsulating space for enzyme species. After dosing enzyme solution into this space, Nafion film tent was cast over the pillar structure to complete the micropillar cavity structure. In this way, the encapsulation of enzyme could be accomplished without any chemical modification. The amount of enzyme species was easily controllable by varying the concentration of the dosing solution. The more amount of enzyme is stored in the sensor, the higher the electrochemical response is produced. One more reason for the sensitivity improvement comes from the large surface area of the micropillar structure. Application of 0.7 V produced the best current response under the condition of pH 7.4. This biosensor showed linear response to the glucose in 0.1~1 mM range with the average sensitivity of $14.06{\mu}A/mMcm^2$. Detection limit was 0.01 mM based on S/N = 3.

High sensitivity biosensor for mycotoxin detection based on conducting polymer supported electrochemically polymerized biopolymers

  • Dhayal, Marshal;Park, Gye-Choon;Park, Kyung-Hee;Gu, Hal-Bon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.243.1-243.1
    • /
    • 2010
  • Devices based on nanomaterials platforms are emerging as a powerful tool for ultrasensitive sensors for the direct detection of biological and chemical species. In this talk, we will report the preparation and the full characterization of electrochemical polymerization of biopolymers platforms and nano-structure formation for electrochemical detection of enzymatic activity and toxic compound in electrolyte for biosensor applications. Formation of an electroactive polymer film of two different compounds has been quantified by observing new redox peak at higher potentials in cyclic voltammogram measurements. RCT value of at various biopolymer concentration based hybrid films has been obtained from electrochemical impedance spectroscopy analysis and possible mechanism for formation of complexes during electrochemical polymerization on conducting substrates has been investigated. Biosensors developed based on these hybrid biopolymers have very high sensitivity.

  • PDF

Electrochemical Kinetic Assessment of Rose Tissue Immobilized Biosensor for the Determination of Hydrogen Peroxide (과산화수소 정량을 위한 장미조직 함유 바이오센서의 전기화학 속도론적 고찰)

  • Rhyu, Keun-Bae
    • Applied Chemistry for Engineering
    • /
    • v.25 no.1
    • /
    • pp.107-112
    • /
    • 2014
  • Using a chlorosulphonated polyethylene rubber solution for a binder of graphite powder and ferrocene for a mediator, a rose leaf tissue-embedded biosensor was built. Linearity on the Hanes-Woolf plot showed the reduction of the substrate was attained through the catalytic power of the rose peroxidase in the experimental range of electrode potential. Furthermore, 10 or more electrochemical parameters demonstrated that the electrode exerts its sensing ability quantitatively. The foregoing gave the full conviction that rose tissue can be used in place of the currently marketed enzyme for the practical use of enzyme electrode.

Investigations with respect to the electrochemical properties of carbon paste electrode fabricated using polybutadiene binder (폴리부타디엔 결합재를 이용하여 만든 탄소반죽전극의 전기화학적 특성에 관한 연구)

  • Yoon, Kil-Joong
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.49-54
    • /
    • 2007
  • For the practical use as a biosensor, a rubber electrode bound by polybutadiene was newly devised for the determination of hydrogen peroxide. Then its electrochemical behaviors were investigated. The signal could be obtained at low electrode potential between 0.0 ~ -0.5 V (vs. Ag/AgCl) with a detection limit of $1.4{\times}10^{-4}M$ and its potential dependence was linear in the experimental range. Especially its Lineweaver-Burk plot showed a very good linearity giving the evidence of a good enzyme immobilization on the surface of the electrode. And mechanical stability of the electrode resulted from using rubber binder presented a new possibility for the practical use of biosensor.