• Title/Summary/Keyword: electro-membrane process

Search Result 50, Processing Time 0.027 seconds

Application of Electro-membrane for Regeneration of NaOH and H2SO4 from the Spent Na2SO4 Solutions in Metal Recovery Process (금속회수공정에서 발생되는 Na2SO4 폐액으로 부터 NaOH 및 H2SO4 재생을 위한 Electro-membrane 응용)

  • Cho, Yeon-Chul;Kim, Ki-Hun;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.31 no.5
    • /
    • pp.3-19
    • /
    • 2022
  • Electro-membrane technology is a process for separating and purifying substances in aqueous solution by electric energy using an ion exchange membrane with selective permeability, such as electrodialysis (ED) and bipolar electrodialysis (BMED). Electro-membrane technology is attracting attention as an environmental friendly technology because it does not generate by-products during the process and the recovered base or acid can be reused during the process. In this paper, we investigate the principles of ED and BMED technologies and various characteristics and problems according to the cell configuration. In particular, by investigating and analyzing research cases related to the treatment of waste sodium sulfate (Na2SO4), which is generated in large amounts during the metal recovery process.

Characteristics of Crossflow Electro-microfiltration Process for Treatment of Oily Waste Water (오일함유 폐수 처리를 위한 전기정밀여과 공정 특성)

  • 최왕규;이재원;이근우
    • Membrane Journal
    • /
    • v.12 no.4
    • /
    • pp.216-225
    • /
    • 2002
  • Experimental study on the crossflow electro-microfi1tation of simulated oil emulsion waste water was carried out with polypropylene microfiltration membrane to evaluate the applicability of electrofiltration process in the treatment of oily waste water generated from many industries including nuclear field. The effects of electric field strength transmembrane pressure, crossflow velocity, and oil emulsion concentration on the permeate flux were investigated. In electro-microfiltration process using the external electric field, significant enhancement of permeate flux was achieved by diminishing membrane fouling and it was shown that considerable permeate flux can be maintained for long-term operation compared with conventional membrane filtration process without an electric field.

Polycarprolactone Ultrafine Fiber Membrane Fabricated Using a Charge-reduced Electrohydrodynamic Process

  • Kim, Geun-Hyung;Yoon, Hyeon;Lee, Haeng-Nam;Park, Gil-Moon;Koh, Young-Ho
    • Macromolecular Research
    • /
    • v.17 no.7
    • /
    • pp.533-537
    • /
    • 2009
  • This paper introduces a modified electro spinning system for biomedical wound-healing applications. The conventional electrospinning process requires a grounded electrode on which highly charged electro spun ultrafine fibers are deposited. Biomedical wound-healing membranes, however, require a very low charge and a low level of remnant solvent on the electrospun membrane, which the conventional process cannot provide. An electrohydrodynamic process complemented with field-controllable electrodes (an auxiliary electrode and guiding electrodes) and an air blowing system was used to produce a membrane, with a considerably reduced charge and low remnant solvent concentration compared to one fabricated using the conventional method. The membrane had a small average pore size (102 nm) and high porosity (85.1%) for prevention of bacterial contamination. In vivo tests on rats showed that these directly electro spun fibrous membranes produced using the modified electro spinning process supported the good healing of skin bums.

Effect of operating condition of electro-coagulation on the membrane filtration resistances of activated sludge (전기응집 조건이 활성슬러지 막 여과 저항에 미치는 영향)

  • Hong, Sung-Jun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2314-2320
    • /
    • 2015
  • MBR (Membrane Bio-Reactor) process is known to consume enormous energy to control membrane fouling. To solve this problem, electro-coagulation technique has been applied to MBR. A series of electro-coagulation was applied to activated sludge suspension under different current density condition. After the electro-coagulations, membrane filtration of the activated sludge suspensions was conducted to investigate the effect of electro-coagulation on the fouling. As current density increased 10 to 40A/m2, the total fouling resistance (Rc+Rf) decreased from 18 to 79%, showing that the electro-coagulation improved the membrane filtration efficiency. Both the organic concentration in bulk and the particles size distribution were not nearly changed before and after the electro-coagulation. The enhanced filtration efficiency might be due to the aluminum hydroxide generated from chemical precipitation, which can be acted as a dynamic membrane preventing a deposition of foulants on membrane surfaces.

Performance Enhancement of Ion-Exchange Membranes Using Nanomaterials (나노물질을 이용한 이온교환막의 성능 향상)

  • Moon-Sung Kang
    • Membrane Journal
    • /
    • v.33 no.6
    • /
    • pp.315-324
    • /
    • 2023
  • Ion-exchange membrane (IEM), is a key component that determines the performance of the electro-membrane processes. In this review, the latest research trends in improving the performance of IEMs used in various electro-membrane processes through modification using carbon-based and metal-based nanomaterials are investigated. The nanomaterials can be introduced into IEMs through various methods. In particular, carbon-based nanomaterials can strengthen their interaction with polymer chains by introducing additional functional groups through chemical modification. Through this, not only can the ion conductivity of IEM be improved, but also the permselectivity can be improved through the sieving effect through the layered structure. Meanwhile, metal-based nanomaterials can improve permselectivity through sieving properties using the difference in hydration radius between target ions and excluded ions within a membrane by using the property of having a layered or porous structure. In addition, depending on the characteristics of the binder used, ion conductivity can be improved through interaction between nanomaterials and binders. From this review, it can be seen that the properties of IEMs can be effectively controlled using carbon-based and metal-based nanomaterials and that research on this is important to greatly improve the performance of the electro-membrane process.

Evaluation on the Electro-electrodialysis for hydrogen production by thermochemical water-splitting IS process (열화학적 수소제조 IS 프로세스의 효율향상을 위한 전해-전기투석의 실험적 평가)

  • Hong, Seong-Dae;Kim, Jeong-Geun;Lee, Sang-Ho;Choi, Sang-Il;Bae, Ki-Kwang;Hwang, Gab-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.13-16
    • /
    • 2006
  • Electro-electrodialysis (EED) experiments were carried out for the HI concentration from HIx $(HI-H_2O-I_2)$ solution to improve the Hl decomposition reaction in the thermochemical water-splitting is (iodine-Sulfur) process. EED cell is composed of the collector electrode and electrolyte. Nafion 117 which was cation exchange membrane used as an electrolyte, and the activated carbon cloth used as an electrode. The HI concentration experiment was carried out using the HIx solution and molar ratio of the $I_2$ were varied from 1 to 3 mole. The cell voltages were decreased as temperature increase. And, membrane properties such as transport number of proton and electro-osmosis coefficient were decreased as temperature increase

  • PDF

Modeling of the effect of current density and contact time on membrane fouling reduction in EC-MBR at different MLSS concentration (EC-MBR 공정의 MLSS, 전류밀도 및 접촉시간이 막 오염 감소에 미치는 영향 모델링)

  • Kim, Wan-Kyu;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.111-119
    • /
    • 2019
  • Electro-coagulation process has been gained an attention recently because it could overcome the membrane fouling problems in MBR(Membrane bio-reactor). Effect of the key operational parameters in electro-coagulation, current density(${\rho}_i$) and contact time(t) on membrane fouling reduction was investigated in this study. A kinetic model for ${\rho}_i$ and t required to reduce the membrane fouling was suggested under different MLSS(mixed liquor suspended solids) concentration. Total 48 batch type experiments of electro-coagulations under different sets of current densities(2.5, 6, 12 and $24A/m^2$), contact times(0, 2, 6 and 12 hr) and MLSS concentration(4500, 6500 and 8500mg/L) were carried out. After each electro-coagulation under different conditions, a series of membrane filtration was performed to get information on how much of membrane fouling was reduced. The membrane fouling decreased as the ${\rho}_i$ and t increased but as MLSS decreased. Total fouling resistances, Rt (=Rc+Rf) were calculated and compared to those of the controls (Ro), which were obtained from the experiments without electro-coagulation. A kinetic approach for the fouling reduction rate (Rt/Ro) was carried out and three equations under different MLSS concentration were suggested: i) ${\rho}_i^{0.39}t=3.5$ (MLSS=4500 mg/L), ii) ${\rho}_i^{0.46}t=7.0$ (MLSS=6500 mg/L), iii) ${\rho}_i^{0.74}t=10.5$ (MLSS=8500 mg/L). These equations state that the product of ${\rho}_i$ and t needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.

A Study on the Pd-Ni Alloy Hydrogen Membrane using the Porous Nickel Metal Support (다공성 Ni 금속 지지체를 사용한 Pd-Ni 합금 수소 분리막 연구)

  • Kim Dong-Won;Um Ki-Youn;Kim Sang-Ho;Park Jong-Su
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.5
    • /
    • pp.289-295
    • /
    • 2004
  • A dense palladium-nikel (Pd-Ni) alloy composite membrane has been fabricated on microporous nickel support mixed with submicron/micron nickel powder instead of mesoporous stainless steel support. Plasma treatment process is introduced as pre-treatment process instead of HCI activation. Pd-Ni alloy composite membrane prepared by electro plating was fairly a uniform and dense surface morphology. The membrane was characterized by permeation experiments with hydrogen and nitrogen gases at temperature 773 K and pressure 2.2 psi. The results showed that hydrogen ($H_2$) permeance was 27 ml/$\textrm{cm}^2$ㆍatmㆍmin and hydrogen/ nitrogen ($_H2$$N_2$) selectivity was 8 at 773 K.

The Fabrication of Ion Exchange Membrane and Its Application to Energy Systems (고분자 이온교환막의 제조와 이온교환막을 이용한 에너지 공정)

  • Kim, Jae-Hun;Ryu, Seungbo;Moon, Seung-Hyeon
    • Membrane Journal
    • /
    • v.30 no.2
    • /
    • pp.79-96
    • /
    • 2020
  • Secondary energy conversion systems have been briskly developed owing to environmental issue and problems of fossil fuel. They are basically operated based on electro-chemical systems. In addition, ion exchange membranes are one of the significant factors to determine performance in their systems. Therefore, the ion exchange membranes in suitable conditions must be developed to improve the performance for the electro-chemical systems. These ion exchange membranes can be classified into various types such as cation exchange membrane, anion exchange membrane and bipolar membrane. Their membranes have distinct characteristics according to the chemical, physical and morphological structure. In this review, the types of ion exchange membranes and their fabrication processes are described with main characteristics. Moreover, applications of ion exchange membranes in newly developed energy conversion systems such as reverse electrodialysis, redox flow battery and water electrolysis process are described including their roles and requirements.

Effect of electrocoagulation on sludge characteristics in EC-MBR (EC-MBR에서 전기응집이 슬러지 특성에 미치는 영향)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.42-49
    • /
    • 2017
  • The application of electro-coagulation has been attempted to control the membrane fouling problem in a MBR (Membrane Bio-Reactor). This study examined the effects of the operating parameters (current density and contact time) of the electro-coagulation process on the change in the characteristics of activated sludge. The current density changed from 2.5 to 12, $24A/m^2$, and the contact time was varied from 0 to 2 and 6 hr, respectively. At a current density of $24A/m^2$ and 6 hr of operation, the MLSS changed from 6,800 to 7,000 mg/L (3% increase), but the MLVSS did not increase significantly. After 6 hr of operation, the soluble COD decreased from 71 to 37 mg/L under the $24A/m^2$ condition, from 113 to 67 mg/L under the $12A/m^2$ condition, and from 84 to 80 mg/L under the $2.5A/m^2$ condition. On the other hand, soluble-TN and -TP concentration showed slight changes. The soluble-EPS and Bound-EPS concentration decreased slightly with increasing current density. The membrane filtration performance of activated sludge before and after electro-coagulation was compared. The filtration resistances after electro-coagulation decreased from 6 to 61 %, particularly as the current density and contact time were increased. This indicates that electro-coagulation can be used to control membrane fouling in the MBR process.