• Title/Summary/Keyword: electrical tree

Search Result 591, Processing Time 0.025 seconds

A Study on Insulation Characteristics of Low Density Polyethylene Contained Various Additives (첨가제를 함유한 저밀도 폴리에틸렌의 절연특성에 관한 연구)

  • Lee, Chung;Kim, Gyu-Baek;Ryu, Boo-Hyung;Kim, Ki-Yup;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.483-486
    • /
    • 1999
  • The treeing inhibitors of barbituric acid derivatives and azocompounds effects on the electrical properties of crosslinked low density polyethylene were investigated. The electrical treeing parameters for tree inception voltage, AC breakdown strength. volume resistivity, capacitance and dissipation factor at 1Mz and thermoluminescence measurements were discussed. From the results, 4- (4-nitrophenylazo) resorcinol among the treeing inhibitors was shown good insulation characteristics.

  • PDF

Dependence of the Partial Discharge Characteristics of Ultra-high Voltage Cable Insulators on the Measuring Temperature

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Hyuk-Jin;Lee, Kang-Won;Kim, Won-Jong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.186-192
    • /
    • 2008
  • Cross linked polyethylene (XLPE) insulators are used as insulation in ultra-high voltage electric power cables. This study investigated the electrical properties of XLPE at different temperatures. The electrical properties of the changing tree phenomenon was examined as a function of temperature applied to the electrical conductors by measuring the partial discharge at $25^{\circ}C$ to $80^{\circ}C$ and applied voltages to the electrodes ranging from 1 kV to 40 kV. The activity of the partial discharge was examined at various temperatures using the K-means distribution. The results revealed the specimen at $80^{\circ}C$ to have the lowest inception voltage and breakdown voltage. In addition, the core of clusters was moved $0^{\circ}$ and $180^{\circ}$ at the positive region and $180^{\circ}$ and $360^{\circ}$ in the negative region in the K-means. The distribution of clusters was concentrated on the inception condition and spread out widely at the breakdown voltage.

Estimation of fruit number of apple tree based on YOLOv5 and regression model (YOLOv5 및 다항 회귀 모델을 활용한 사과나무의 착과량 예측 방법)

  • Hee-Jin Gwak;Yunju Jeong;Ik-Jo Chun;Cheol-Hee Lee
    • Journal of IKEEE
    • /
    • v.28 no.2
    • /
    • pp.150-157
    • /
    • 2024
  • In this paper, we propose a novel algorithm for predicting the number of apples on an apple tree using a deep learning-based object detection model and a polynomial regression model. Measuring the number of apples on an apple tree can be used to predict apple yield and to assess losses for determining agricultural disaster insurance payouts. To measure apple fruit load, we photographed the front and back sides of apple trees. We manually labeled the apples in the captured images to construct a dataset, which was then used to train a one-stage object detection CNN model. However, when apples on an apple tree are obscured by leaves, branches, or other parts of the tree, they may not be captured in images. Consequently, it becomes difficult for image recognition-based deep learning models to detect or infer the presence of these apples. To address this issue, we propose a two-stage inference process. In the first stage, we utilize an image-based deep learning model to count the number of apples in photos taken from both sides of the apple tree. In the second stage, we conduct a polynomial regression analysis, using the total apple count from the deep learning model as the independent variable, and the actual number of apples manually counted during an on-site visit to the orchard as the dependent variable. The performance evaluation of the two-stage inference system proposed in this paper showed an average accuracy of 90.98% in counting the number of apples on each apple tree. Therefore, the proposed method can significantly reduce the time and cost associated with manually counting apples. Furthermore, this approach has the potential to be widely adopted as a new foundational technology for fruit load estimation in related fields using deep learning.

NETWORK RECONFIGURATION ALGORITHM FOR AUTOMATED DISTRIBUTION SYSTEM BASED ON THE BEST-FIRST TREE SEARCH (경험적 탐색기법에 근거한 배전계통의 선로 재구성 앨고리즘)

  • Jung, Kyung-Hee;Kim, Ho-Yong;Ko, Yun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.350-353
    • /
    • 1991
  • This study develops an expert system which solves the problems of the MTr/feeder overloads and the feeder constraints in automated radial distribution systems. Then, the objective is to perform the network reconfiguration by switching the tie and sectionalizing switches which eliminates the system violation, while achieving the load balance of the MTrs/feeders. To reduce the search space, an expert system based on heuristic rules is presented, and implemented in AI language Prolog. This system adopts the best-first tree search technique. The computational results are also prepared to show the performance of the heuristic algorithm developed.

  • PDF

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

A Modeling of Discrete Event System Using Temporal Logic Framework and Petri Net (시간논리 구조와 Petri Net의 합성방법을 사용한 이산사건 시스템의 모델링)

  • Kim, Jin-Kwon;Mo, Young-Seung;Ryu, Young-Guk;Hwang, Hyung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.838-840
    • /
    • 1999
  • In this paper, modeling and analysis of discrete event systems by temporal logic frame works and petri net is considered. The reachability tree of the petri net can be used to solve the safeness, boundedness, conservation and coverability problems of discrete event systems. But the reachability tree of the petri net do not solve reachability and liveness problems in general. We proposed a method that synthesised the petri net and the temporal logic frameworks. This method slove some problems of petri net by logical representation of temporal logic frameworks.

  • PDF

Merits of all-electric subsea production control system

  • Oh, Jin-Seok;Kang, Se-Ra
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.162-168
    • /
    • 2014
  • Recently, researches on all-electric subsea system have been in progress. This paper describes a subsea tree using a lot of electrical signal and subsea control system. The way of subsea control is classified as all-electric systems or electro hydraulic systems. One of that has more merits in terms of cost, weight, power consumption, etc. because it uses electric signal instead of hydraulic signal. This paper describes the difference of each system's power consumption and simulation. As the result, if each system applies the same number of sensors, actuators, etc. The power consumption of all-electric system's load is less than at least 400kWh/day compared to the electro hydraulic system load.

A Computer method in Economical Design of Conductor Sizes of Distribution Lines (전자계산기에 의한 배전선료전선 단면적의 경제적 설계법)

  • Young Moon Park
    • 전기의세계
    • /
    • v.24 no.5
    • /
    • pp.107-110
    • /
    • 1975
  • This paper describes computational algorithms and a computer program for optimum determinations of wire conductor sizes of radial or tree-type distibution lones with given constraints. Here, The objective function is defined as the total summation of the volume or weight of respective conductor materials required for buildingup the entire distributing system. Four categories of constraints are applied to the obiective function. That is, on the respective load points constraint is imposed by a specified voltage drop limit, and the respective line elements are capable of carrying the current safely(safety current) and also must maintain the minimum thickness in viewpoint of mechanical strength and legal requirements. And finally, the conductor sizes have to be selected among the standardized size levels of the products. These kinds of optimization problems cannot be solved by the ordinary optimization tediniques such as the Linear Programming Method, SUMT Technique, etc. This paper, therefore, successfully devised the powerful alorithms to solve the problem, using the particular properties or characteristics ingerent to the radial or tree-type distribution system. The computer program developed from the algorithms was applied to several sample systems and shown to be exact and very efficient.

  • PDF

A Qualitative Fault Tree Analysis to Emergency Engine Stop of KSR-III (KSR-III 비상엔진중단 상황에 대한 정성적 결함 트리 분석)

  • Shin, Myoung-Ho;Seo, Jin-Ho;Hong, Il-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2574-2576
    • /
    • 2002
  • 본 논문에서는 가압형 액체 추진 로켓인 KSR-III의 위험도 관리에 Fault Tree Analysis (FTA)를 적용한다. 미니멀 컷 set과 같은 FTA 구조 분석 방법을 소개하고, KSR-III 비상엔진중단 상황에 대해 정성적 FTA를 적용한다. 정성적 FTA를 통해서 KSR-III 추진기관 시스템의 구조적 특성을 명확히 하고 비상엔진중단을 야기시키는 컴포넌트 레벨에서의 실패와 작동 시퀀스의 조합에서의 문제 등을 명확히 하였다.

  • PDF

A Proposal of the Directed Product Graph and Its Applications to Network Analysis (I) (방향성 적선도의 제안과 회로망 해석에의 응용 (I))

  • 전선미;김수중
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.2
    • /
    • pp.19-23
    • /
    • 1984
  • A new directed product graph(DPG) is proposed from the product graph for electrical networks. By introducing the direction of an dege and the concept of a loop to product graph, it is more easy and rapid to obtain topologically the denominator of Mason's formula without relation of the sign rule and without arising terms cancelled. Also the constraints of tree selection at a given network-graph can be removed.

  • PDF