• Title/Summary/Keyword: electrical test

Search Result 7,395, Processing Time 0.04 seconds

Development of Electric safety monitoring system for reducing the electrical fire at traditional market (재래시장 전기화재 감소를 위한 전기안전감시시스템 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.259-262
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of traditional market developed the electric safety monitoring system which is suitable in traditional market. With for this did the actual condition investigation about electrical equipment of traditional market and we constructed Test-bed for testing reliability of electric safety monitoring system. Also experiment led in Test-bed and confirmed a stability. This paper following will be used with the data for the reliability security of the electric safe system operation which follows in the traditional market actual proof equipment construction which will be advanced.

  • PDF

A Study on the Improvement of Lifetime with Short-Term Test Method of AC PDP (AC PDP의 장수명 인자의 단시간 시험 방법에 의한 수명 증대 기술에 관한 연구)

  • Kim, Yun-Gi;Choi, Min-Seok;Lyu, Seong-Nam;Park, Cha-Soo;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1576-1578
    • /
    • 2001
  • In this paper, a short-term test method to diagnose and estimate the lifetime of AC PDP(Plasma Display Panel) has been proposed. As using this method, we investigated the lifetime of MgO layer in AC PDP. The lifetime was increased in proportion to an MgO thickness but it was allowed when the MgO thickness was raised until 5000$\AA$. Over 5000$\AA$, the lifetime was saturated with a thickness of MgO layer.

  • PDF

Development of Waterproof Jacket Materials for Power Cables

  • Han, Yong-Huei;Jung, Jong-Wook;Kwon, Tae-Ho;Song, Hyun-Seok;Koo, Kyo-Sun;Han, Byung-Sung
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.4
    • /
    • pp.146-154
    • /
    • 2003
  • This paper describes various characteristics of the new compounds for cable jackets and model cables advanced in waterproof performance in order to essentially solve the problems of underground (URD) distribution class power cable failures. Several compounds were manufactured by the inclusion of additives to base resins available in Korea and tested for basic property, mechanical and electrical characteristics. Two model cables were created by using the compounds determined in the test as being the most appropriate for new structured model cable jacket material. The waterproof performance and mechanical strength of the new cable jackets were verified by applicable tests. As a result, MDPE and LLDPE compounds were superior as cable jackets in both mechanical and electrical characteristic aspects when compared with conventional PVC. In addition, the model cables composed of the new compounds based on MDPE showed good quality results in the water permeability test.

The Development and Field Test of DC FRP Support Insulator Prototype (직류용 FRP 지지애자 개발 및 현장설치 적응시험)

  • Sim, Jae-Suk;Kim, Yoon-Sik;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1979-1983
    • /
    • 2011
  • FRP(Fiber Reinforced Plastic) support insulators for DC(direct current) were developed and their electrical and mechanical characteristics were investigated. Electrical tests were carried out to measure flashover voltages under common use frequency condition. Tensile and bending tests were performed for the mechanical characteristics. The test results showed that FRP support insulators have superior voltage resistances and strengths to porcelain insulators. Field test also is carried out to measure adaptation and to compensate the defect. The test result showed that a new product has no defect in electrical and mechanical.

  • PDF

Domestic Technical Standards and Performance Test of Photovoltaic PCS for Renewable Energy (신재생에너지용 태양광 PCS 국내 기술기준 및 성능시험)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.479-484
    • /
    • 2018
  • This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)-Characteristics of the utility interface. This standard tests utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1)voltage, current and frequency, 2)normal voltage operating range, 3)DC injection, 4)normal frequency operating range, 5)harmonics and 6)waveform distortion, 7)power factor of PV inverter. Therefore in this paper each test item of domestic technical standard is studied and analyzed and finally full tested by PV inverter performance function.

The analysis of growth and electrical characteristics of micro-crack with thermal effect in PV module (PV 모듈에서 온도 영향에 의한 micro-crack 성장과 전기적 특성 분석)

  • Song, Young-Hun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1318-1319
    • /
    • 2011
  • In this paper, we analyzed of growth and electrical characteristics of micro-cracks with thermal effect in PV module. The micro-cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because microcracks accelerated aging by thermal cycling test. according to IEC61215. Before every test, we checked output and EL image of PV module.

  • PDF

A Study on tests process for verification of AC Traction system performance (교류 급전시스템 성능검증을 위한 시험방안에 관한 연구)

  • Jung, Ho-Sung;Lee, Ki-Won;Kim, Joo-Rak;Han, Moon-Seob;Kim, Jin-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2202-2203
    • /
    • 2011
  • AC substation of urban transit supplies a suitable AC power on electricity vehicles. AC substation is verified electrical safety of system through pre-operation inspection on electrical installations to be supplied power from KEPCO. However, because test items and method for AC traction system are unprepared on pre-operation inspection, the general safety and performance verification of AC traction system are very insufficient. Therefore this paper analyze the test examples such as factory equipment tests, factory combined tests and railway tests for the safety and performance verification of AC traction system and present a suitable test items and test standard in domestic.

  • PDF

Analysis of RCD'S Material Degradation by Weathering Test (내후성시험에 의한 누전차단기 재질변화 분석)

  • Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok;Yong, Shin-Jin;Kim, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • Fault rate of RCD is increasing due to deterioration and long period usage in domestic. According to Korean standards, the RCDs are installed in panel boards. When RCDs are installed at outdoor, the RCDs must be protected from uv, water etc. by using the housing. However, many RCDs are exposed to the external environment. As a results, many RCDs have malfunctions so that cause the electrical accidents. The RCDs manufactured by four makes were used as the sample to weathering test. Futhermore, those were analyzed the ingredients of RCD'S using SEM, EDX and FT-IR/TAR before and after weathering test.

Basic Study of Degradation Test for Magnetic Contactors and Reliability Centered Maintenance

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.441-444
    • /
    • 2007
  • The mechanical endurance is the critical characteristic of Magnetic contactors (MCs), which are widely used in such industrial equipments as elevators, cranes, and factory control rooms in order to close and open the control circuit. Testing time, however, is so long in most cases that some method of reducing the testing period is required. Therefore, the degradation test by the detected vibration of MCs is developed to reduce the testing time in this work. The degradation test data are analyzed and the prediction model is provided. Also, the possibility of this technology for Reliability Centered Maintenance (RCM) will be shown. This will reduce the period of the product development and raise the reliability of the equipment in power distribution.

A Study on the DC Voltage Withstand test for the Ageing of XLPE Power Cable (직류내전압 시험이 전력케이블(CV) 절연체에 미치는 영향연구)

  • Lee, Jun;Lim, Yong-Bae;Kim, Jong-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.613-616
    • /
    • 1999
  • Polyehtylene[PE] in polymer insulation materials of used power cable have carried out in abundance of experiment and study for electrical conduction, insulation breakdown, dielectric character and so on. when apply to field for power cable to make PE, application of DC withstand test to put in practice for inspection is get to effect accumulated space charge. In this paper, to make use of Pulsed Electro-Acoustic(PEA), It is analysis to take shape space charge under AC and DC, clear up the point at issue for DC withstand test impressing

  • PDF