Receiver Protection from Electrical Shock in Vehicle Wireless Charging Environments

  • Park, Taejun;Hwang, Kwang-il
    • Journal of Information Processing Systems
    • /
    • v.16 no.3
    • /
    • pp.677-687
    • /
    • 2020
  • This paper deals with the electrical shock that can occur in a car wireless charging system. The recently released the Wireless Power Consortium (WPC) standard specifies that the receiver must be protected from the radio power generated by the transmitter and presents two scenarios in which the receiver may be subjected to electrical shock due to the wireless power generated by the transmitter. The WPC also provides a hardware approach for blocking the wireless power generated by the transmitter to protect the receiver in each situation. In addition, it presents the hardware constraints that must be applied to the transmitter and the parameters that must be constrained by the software. In this paper, we analyze the results of the electric shock in the vehicle using the WPC certified transmitter and receiver in the scenarios presented by WPC. As a result, we found that all the scenarios had electrical shocks on the receiver, which could have a significant impact on the receiver circuitry. Therefore, we propose wireless power transfer limit (WPTL) algorithm to protect receiver circuitry in various vehicle charging environments.

The Infrastructure Case for Reproduction or Analysis of The Mechanism on The Fire of The Electrical Appliances (가전제품 화재 메커니즘 재현 및 분석을 위한 인프라 구축)

  • Jang, In-Hyeok;Lee, Chang-Hoon;Lee, Young-Joo;Lim, Hong-Woo
    • Journal of Applied Reliability
    • /
    • v.15 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • In this paper, The infrastructure case for reproduction or analysis of the mechanism on the fire or the electrics shock of the electrical appliances is proposed. The various electrical appliances(Washing machine, Ballast, Electric heaters, Electronic switches, Mobile phone chargers) used in the home can be tested on the high voltage and over current test through the implementation of the infrastructure. The electrical tests of fire and electric shock consists of the high voltage of maximum 5000 V and over current test of 3 steps(90 A, 60 A, 40 A) and noise test. The mechanism of the fire and the electric shock tests reproduced are analyzed through the monitoring system and the oscilloscope. The electronics manufacturers can prevent accidents through the tests of the electronics factor reproduced and the analysis of the infrastructure designed.

Shock Graph for Representation and Modeling of Posture

  • Tahir, Nooritawati Md.;Hussain, Aini;Abdul Samad, Salina;Husain, Hafizah
    • ETRI Journal
    • /
    • v.29 no.4
    • /
    • pp.507-515
    • /
    • 2007
  • Skeleton transform of which the medial axis transform is the most popular has been proposed as a useful shape abstraction tool for the representation and modeling of human posture. This paper explains this proposition with a description of the areas in which skeletons could serve to enable the representation of shapes. We present algorithms for two-dimensional posture modeling using the developed simplified shock graph (SSG). The efficacy of SSG extracted feature vectors as shape descriptors are also evaluated using three different classifiers, namely, decision tree, multilayer perceptron, and support vector machine. The paper concludes with a discussion of the issues involved in using shock graphs to model and classify human postures.

  • PDF

A Study on the Protection of Electric Shock, in Low Voltage (저전압에서의 감전보호에 관한 연구)

  • 이재인
    • Journal of the Korean Society of Safety
    • /
    • v.4 no.1
    • /
    • pp.83-90
    • /
    • 1989
  • Recently, due to the increase of 220V distribution lines and equipments preventive measures to cope with several kinds of electric accidents is revealed as an urgent problem. This study investigates the following matters; the cause and present condition of e1ectric shock accident, the influence of electric shock on human body, the safety limit of electric shock, the method of distribution voltage, the insulation of electrical load apparatus, the teachnics of electric shock prevention and foreign materials concerned with this subject etc. This paper present the fundamental cause of electric shock and syntbetic preventive counter measure of electric shock, too.

  • PDF

Experiments to Simulate an Electric Shock Accident of a high Voltage using a Human Body Model (인체모형을 이용한 고전압(22.9[kV]) 감전사고 모의 실험)

  • Roh, Young-Su;Jang, Tae-Jun;Kwak, Hee-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.63-68
    • /
    • 2006
  • Recent statistical data regarding electric shock accidents have been analyzed to examine the electric shock accidents occurred at the voltage of 22,900[V], In order to demonstrate the mechanism of the 22,900[V] electric shock accident, a number of experiments to simulate electric shock accidents have been performed based on the analysis results. In the experiment, the current flowing through a human body model was measured to quantitatively analyze the hazards of the simulated electric shock accidents in various situations. As a result of the experiment, it was shown that once an electric shock accident occurred the accident proved fatal to the human body, regardless of electric shock situation.

Design and Analysis of MEMS Vibrating Ring Gyroscope Considering High-g shock reliability (고내충격용 MEMS 진동형 링 자이로스코프 설계 및 분석)

  • Yoon, Sung-Jin;Park, U-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1440-1447
    • /
    • 2015
  • This paper describes a study for anti high-shock design of MEMS vibrating ring gyroscope. Structure models was made by MEMS technology processing. MEMS Vibrating Ring Gyroscope mechanical structure were not only anti-high shock simulated with the LS Dyna Ver 971 software but also with mathematical analysis and the finite element method in order to confirm the shock reliability. Shock test result of a MEMS vibrating gyroscope being developed to have gun-hardened survivability while maintaining tactical grade navigation performance for application to various guided projectiles.

Protection Techniques Against Electric Shock in Low Voltage DC Grounding Systems Depending on the Analysis of Earth Fault Current Paths (저압직류 접지시스템의 지락경로 흐름 분석에 따른 감전 보호기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Choi, Myeong-Il;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.232-238
    • /
    • 2016
  • This paper presents protection techniques against electric shock in low voltage DC(direct current) grounding systems depending on the analysis of earth fault current paths. Firstly, the comparison between alternating current and direct current on human was conducted, and current threshold values for each current path and for long duration were analyzed. Secondly, the analyses of the earth fault current flows were performed depending on the grounding types and earth fault conditions. Lastly, based on these analyses, adequate protection measures of electric shock depending on low voltage DC grounding types were provided.

An Investigation Into the Actual Condition of Electrical Equipments Installation and Management for Establishing the Countermeasures Against the Electric Shock in Submerged Underground (지하구내 침수시 감전 방지대책 수립을 위한 전기설비 설치 및 관리실태 조사)

  • Jung, Jin-Soo;Jung, Jong-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.84-90
    • /
    • 2008
  • This paper describes the investigation into the actual condition of electrical equipments installation and management for establishing the countermeasures against the electric shock in submerged underground. The investigation was carried out for 27 underground premises in conurbation including Seoul, and potential of the exposed electrical equipments negatively affecting on human safety when disaster occurs was measured. The objects to which measurement was carried out were as follows; electrical source; advertising lighting; power equipment. As a result, it was confirmed that potentials more than 230[V] were induced in some equipments. In addition, the electrical equipments installed in most conventional underground premises were left unmanaged.

A Study of Electrical Control Kit for Damping Force of Automotive Shock Absorber (자동차 충격흡수장치용 감쇠력 조정 전자제어장치 연구)

  • Sohn, Il-Seon;Lee, Jeong-Goo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.1-6
    • /
    • 2008
  • The performance of shock absorber is directly related to the car behavior and performance, both for handling and comfort. Most of compact car are assembled the passive shock absorber for cost effect but some of compact driver want better performance of shock absorber than standard parts. Therefore, they want the semi-active suspension control system instead of standard damper system. But they only can change the mechanical damping control shock absorber at A/S market. The mechanical damping control shack absorber can not vary the damping force in driving condition so they do not satisfy the mechanical damping control shock absorber system. In this study, electrically damping force controlled shock absorber system is developed based on the mechanical damping force control damper system. This system can vary damping force by switch on dashboard in driving condition. And, this system can satisfy the requirement of tuning market. Therefore, it is expected the system to show the engineering capability of korean damper company and to increase export market share to oversea damper market.

Shock Detection Method and Anti-shock Controller in Optical Disc System (광디스크 시스템에서의 충격 대응 제어기 설계와 검출 방법)

  • Choi, Byoung-Ho;Choi, Ga-Hyoung;Ra, Won-Sang;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.232-233
    • /
    • 2008
  • There are various large shocks in optical disc drive system like human touch and speak sound. In this paper, a nonlinear controller and a detection method are proposed. First, a relay nonlinear controller with dead zone is introduced. The structure of this nonlinear controller is simple and has a small amount of calculation. However, this controller has chattering problem when it is working. We suggest a disturbance detection algorithm using Kalman filter in this paper and it shows effective reduction of chattering. The proposed nonlinear controller using this detection algorithm had good performance for the shock.