• Title/Summary/Keyword: electrical pole

Search Result 1,094, Processing Time 0.022 seconds

Optimum Shape Design of Magnetizing Yoke of 2 Pole PM Motor for Cogging Torque Reduction

  • Koh Chang-Seop;Ryu Jae-Seop;Hong Sun-Ki
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.168-172
    • /
    • 2005
  • A novel cogging torque reduction algorithm is presented for 2-pole permanent magnet DC motor. While the shape of the permanent magnet is changed in the conventional method, the pole shape of the magnetizing yoke is optimized in the presented algorithm. In order to parameterize the shape of the yoke, and the distribution of the residual magnetization of the permanent magnet, the Bezier spline is used. The shape of the magnetizing yoke is optimized using the design sensitivity analysis incorporated with the finite element method and Bezier spline.

The Design and Characteristics Comparison of 600W Class Consequent Pole Type IPMSM (600W급 Consequent Pole Type IPMSM 설계 및 특성 비교)

  • Gim, Gyu-Hwa;Park, Byung-Jun;Kim, Yongn-Tae;KimJang, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1040-1046
    • /
    • 2018
  • The Permanent Magnet Synchronous Motor(PMSM) has various advantages. However, new types of research have been carried out because of rising prices of materials for rare earth magnets used in PMSM and also unstable supply. In this paper, we propose Consequent Pole(CP) type IPMSM for magnet reduction. The shape of CP type IPMSM stator was same with Basic model IPMSM. The design of the rotor shape was proceeded that CP type IPMSM achieved the same output as the basic model IPMSM. Finally, the selected model and IPMSM were compared and discussed.

Influence of Pole Arc and Salient Pole length on Torque of Salient Pole Rotor Type Single Phase SRM (회전자 돌극형 단상 SRM에서 극호와 돌극 길이가 토오크에 미치는 영향)

  • Kim, Jun-Ho;Lee, Eun-Woong;Oh, Young-Woong;Lee, Min-Myung;Yeo, Sang-Kyom
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.107-109
    • /
    • 2001
  • The salient pole rotor type single phase SRM has a salient pole in the rotor in order to use axial direction fluxes and radial direction fluxes simultaneously. A flux linkage between the rotor and the stator are increased because of the salient pole in the rotor. But, the inductance at unaligned position and aligned position is increased together. Therefore, the length of pole are and salient pole should be selected that the inductance increment at aligned position is higher than the inductance increment at unaligned position. On this paper, we will be studied the influence of the pole arc and the salient pole length on the torque of the salient pole rotor type single phase SRM.

  • PDF

The Comparison and Analysis about Earth Resistance for Measuring of Earth Resistance by Measurement Positions of Auxiliary Poles (접지저항 측정을 위한 보조전극 위치에 따른 접지저항 비교 분석)

  • Han, Woon-Ki;Jung, Jin-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.128-133
    • /
    • 2009
  • This paper describes the comparison and analysis about measurement method of earthing resistance by positions of potential pole and current pole. In KOREA, a diagonal by 6.5 times of earthing electrode for measurement of earthing resistances but this method was almost impossible in the downtown area. For solving this problem, in this paper measuring of earthing resistance changing parameters. The parameter was a distances of earthing electrode, potential pole & current pole and the another parameter was an angles of potential pole & current pole. Analysis result, earthing resistance stability that conditions. Fist, distance from earthing electrode to current pole was over 50[m] and distance from earthing electrode to potential pole was over 30[m]. Second, angles of potential pole & current pole was over $45[^{\circ}]$.

Adjustment of Load Regression Coefficients and Demand-Factor for the Peak Load Estimation of Pole-Type Transformers (주상 변압기 최대부하 추정을 위한 부하상관계수 및 수용율 조정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Park, Kyung-Ho;Moon, Jong-Fil;Lee, Jin;Park, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.87-96
    • /
    • 2004
  • This paper summarizes the research results of the load management for pole transformers done in 1997-1998 and 2000-2002. The purpose of the research is to enhance the accuracy of peak load estimation in pole transformers. We concentrated our effort on the acquisition of massive actual load data for modifying the load regression coefficients, which related to the peak load estimation of lamp-use customers, and adjusting the demand-factor coefficients, which used for the peak load prediction of motor-use customers. To enhance the load regression equations, the 264 load data acquisition devices are equipped to the sample pole transformers. For the modification of demand factor coefficients, the peak load currents are measured in each customer and pole transformer for 13 KEPCO (Korea Electric Power Corporation) distribution branch offices. Case studies for 50 sample pole transformers show that the proposed coefficients could reduce estimating error of the peak load for pole transformers, compared with the conventional one.

Finite Element Analysis considering Asymmetric Bridge Converter in 6/4 Switched Reluctance Motor (비대칭 브리지 컨버터를 고려한 6/4 스위치드 릴럭턴스 전동기의 유한요소 해석)

  • Choi, Jae-Hak;Park, Jae-Bum;Lee, Seung-Jun;Ahn, Byeong-Lib;Lee, Ju;Kim, Suk-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.720-722
    • /
    • 2003
  • This paper Presents a design schemes to minimize torque ripple in 6/4 Switched Reluctance Motor (SRM) using transient Finite Element Analysis (FEA) in which the magnetic field is combined with a driving circuit. Pole arcs and switching angles are major design factors. If these design factors are considered independently, the enhancement of SRM Performance is restricted. Therefore, this paper proposes not only optimal combination of stator pole arc and rotor pole arc but also the turn-on and turn-off angles as a function of pole arcs. Especially, turn-on and turn-off angle are formulated from a voltage equation and feasible design ranges are suggested with variable speed.

  • PDF

Radial Force Control of a Novel Hybrid Pole BLSRM

  • Wang, Hui-Jun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.845-853
    • /
    • 2009
  • This paper presents a novel hybrid pole BLSRM (Bearingless Switched Reluctance Motor) and its radial force control scheme. The proposed hybrid pole BLSRM has separated radial force poles and rotating torque poles. According to the FEM analysis, the proposed BLSRM has an excellent linear characteristic of radial force and controllability that is independent from the torque current. The radial force can be produced by the radial force winding which is wound at the separated radial force poles. The rotating torque is produced by the excitation current of the torque windings which are wound at the torque pole. The proposed radial force control scheme is independent of the phase torque winding current. A simple PID controller and look-up table are used to maintain a constant rotor air-gap. The proposed BLSRM and its radial force control scheme are verified by FEM analysis and experimental tests.

Electrical Characteristics of Insulating Paper for Pole Transformers after Accelerated Ageing (주상변압기용 절연지의 가속화 후 전기적 특성)

  • Song, I.K.;Jung, J.W.;Lee, B.S.;Han, Y.H.;Kim, C.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1591-1593
    • /
    • 2001
  • In this paper, the electrical characteristics of Insulating paper, for pole transformers, subjected to accelerated ageing were observed and the results were compared with those of virgin insulating paper. For the experiment, insulating materials for pole transformers were enclosed together in an oil bath and thermally aged under the real pole transformer operating conditions. After the accelerated ageing of the insulating materials, the dielectrics were measured and compared with the results of the virgin ones.

  • PDF

Protect Measures and Impact of Electric Pole for Abnormal Tension of Messenger Wire (전력선 벤드 장력 작용에 대한 전주의 영향)

  • Cho, Hyeon-Seob;Kim, Young-Cho;Kim, Sung-Woon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.302-306
    • /
    • 2006
  • In this study, we analyzed the influence of electrical pole by FEM(Finite Element Method) and developed protective system by designing and interpreting protective system for electrical pole when abnormal strength worked on messenger wire. Protective system did not shed messenger wire under wind pressure and discontent load but did assign a part to preventing rupture of electrical pole through automatically shed messenger wire over fixed strength. Structure of protective system analysis by FEM and prove property by measuring tensile strength for practical product.

  • PDF

Robust pole assignment inside a disk of uncertain linear system (불확정성 선형시스템의 원판내 강인 극점배치)

  • Park, Sang-Min;Kim, Jin-Hoon;Ryu, Jeong-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.431-433
    • /
    • 1997
  • In this paper, we consider the robust pole assignment inside the circular region for linear systems with time-varing uncertainty. The considered uncertainties are the norm bounded uncertainty and the matrix polytopes type uncertainty. Since the considered uncertainties are time-varying, it should remind that the closed loop system be time-varing system. Therefore, we should consider not only the pole assignment but also the stability. We present new conditions that guarantee the robust pole assignment and the robust stability. Finally, we show the usefulness of our results by an example.

  • PDF