임펄스전류에 의한 매설지선의 과도임피던스특성에 대한 모의해석 (Simulated Analysis for the Transient Impedance Behaviors of Counterpoises Subjected to the Impulsive Currents)

  • 조정현;이복희
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1861-1868
    • /
    • 2009
  • A ground electrode subjected to lightning surge current shows the transient impedance behaviors. The ground electrode for protection against lightning should be evaluated in view of the transient grounding impedance and conventional grounding impedance, not ground resistance. The transient impedance characteristics of ground electrodes are influenced by the shape of ground electrode and the soil characteristics, as well as the waveform of lightning surge current. In order to propose a simulation method of analyzing the transient impedance characteristics of the grounding system in practical use, this paper suggests a theoretical analysis method of distributed parameter circuit model to simulate the transient impedance characteristics of counterpoise subjected to lightning surge current. EMTP and Matlab programs were employed to compute the transient grounding impedances of three counterpoises with different lengths. As a consequence, the simulated results using the proposed distributed parameter circuit model are in good agreement with the measured results.

Loop Impedance 측정을 통한 접지계통 비교분석

  • 정진수;한운기;김오환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.211-212
    • /
    • 2009
  • This Paper present about loop impedance measuring method by a comparison & analysis of the earthing systems in IEC60364. And comparing analysis about only considering a resistance and considering resistance & inductance. Result, For measuring of loop impedance than must measured resistance and reactance. And TT earthing system was lower fault current then TN systems, but an electric shock was higher then TN systems.

  • PDF

Online Parameter Estimation for Wireless Power Transfer Systems Using the Tangent of the Reflected Impedance Angle

  • Li, Shufan;Liao, Chenglin;Wang, Lifang
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.300-308
    • /
    • 2018
  • An online estimation method for wireless power transfer (WPT) systems is presented without using any measurement of the secondary side or the load. This parameter estimation method can be applied with a controlling strategy that removes both the receiving terminal controller and the wireless communication. This improves the reliability of the system while reducing its costs and size. In a wireless power transfer system with an LCCL impedance matching circuit under a rectifier load, the actual load value, voltage/current and mutual inductance can be reflected through reflected impedance measuring at the primary side. The proposed method can calculate the phase angle tangent value of the secondary loop circuit impedance via the reflected impedance, which is unrelated to the mutual inductance. Then the load value can be determined based on the relationships between the load value and the secondary loop impedance. After that, the mutual inductance and transfer efficiency can be computed. According to the primary side voltage and current, the load voltage and current can also be detected in real-time. Experiments have verified that high estimation accuracy can be achieved with the proposed method. A single-controller based on the proposed parameter estimation method is established to achieve constant current control over a WPT system.

탄소블록과 동봉의 접지임피던스 비교 분석 (Comparative Analysis on Ground Impedance for a Carbon Block and a Copper Rod)

  • 서재석;박희철;길경석;오재근
    • 한국전기전자재료학회논문지
    • /
    • 제26권6호
    • /
    • pp.472-477
    • /
    • 2013
  • This paper carried out the comparative analysis on ground impedance of a carbon block and a copper rod. Two types of grounding electrode were compared ; a carbon block (L : 1 m, ${\Phi}$ : 245 mm) buried at a depth of 0.8 m and a three-linked copper rod (L : 1 m, ${\Phi}$ : 10 mm) of equilateral triangles with 1 m spacing. Ground impedance depending on applied current source was evaluated by the application of a sine wave current with 60 Hz ~ 3.5 MHz, a fast-rise pulse with rising time of 200 ns, a standard lightning impulse of $8/20{\mu}s$ and a 600 Hz square wave. Ground impedance for both electrodes were almost the same value below 100 kHz, and increased rapidly afterwards. The maximum ground impedance appeared $400{\Omega}$ at around 1.5 MHz. Ground impedance of the carbon block was lower at the square wave and was higher at fast-rise pulse than that of the copper rod. Also, ground impedance as ages showed no difference for the last 8 months. From the results, it is likely that ground performance for both electrodes shows no difference against commercial frequency and lightning impulse current, while the copper rod shows better performance against a fast-rise pulse with rise-time of a few hundred ns.

Simulations of Frequency-dependent Impedance of Ground Rods Considering Multi-layered Soil Structures

  • Lee, Bok-Hee;Joe, Jeong-Hyeon;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.531-537
    • /
    • 2009
  • Lightning has a broad frequency spectrum from DC to a few MHz. Consequently, the high frequency performance of grounding systems for protection against lightning should be evaluated, with the distributed parameter circuit model in a uniform soil being used to simulate grounding impedances. This paper proposes a simulation method which applies the distributed parameter circuit model for the frequency-dependent impedance of vertically driven ground rods by considering multi-layered soil structures where ground rods are buried. The Matlab program was used to calculate the frequency-dependent ground impedances for two ground rods of different lengths. As a result, an increase of the length of ground rod is not always followed by a decrease of grounding impedance, at least at a high frequency. The results obtained using the newly proposed simulation method considering multi-layered soil structures are in good agreement with the measured results.

Classification of the Types of Defects in Steam Generator Tubes using the Quasi-Newton Method

  • Lee, Joon-Pyo;Jo, Nam-H.;Roh, Young-Su
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.666-671
    • /
    • 2010
  • Multi-layer perceptron neural networks have been constructed to classify four types of defects in steam generator tubes. Three features are extracted from the signals of the eddy current testing method. These include maximum impedance, phase angle at the point of maximum impedance, and an angle between the point of maximum impedance and the point of half the maximum impedance. Two hundred sets of these features are used for training and assessing the networks. Two approaches are involved to train the networks and to classify the defect type. One is the conjugate gradient method and the other is the Broydon-Fletcher-Goldfarb-Shanno method which is recognized as the most popular algorithm of quasi-Newton methods. It is found from the computation results that the training time of the Broydon-Fletcher-Goldfarb-Shanno method is much faster than that of the conjugate gradient method in most cases. On the other hand, no significant difference of the classification performance between the two methods is observed.

임피던스 분석법을 이용한 유기발광 다이오드의 전기적 특성 분석 (Electrical property analysis of Organic Light Emitting Diodes using impedance spectroscopy)

  • 박재일;박형준;남은경;정동근;이준신
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.452-453
    • /
    • 2007
  • In this work, enhanced simulation is proposed by using impedance spectroscopy. The impedance spectroscopy is one of the popular methods to measure the electrical property of Organic Light Emitting Diodes. The results show that the equivalent circuit needs a inductance element linked by serial connection and the element of resistance is more important role to decide the electrical property.

  • PDF

인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석 (The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current)

  • 김재현;임용배;이상익;김동우
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석 (Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid)

  • 길형준;송길목;김영석;김종민
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

생체 임픽던스 측정에 의한 상지 운동 감지 시스템 (A Human Arm Movement Detection System Using Electrical Bioimpedance Measurement)

  • 김종찬;김수찬;남기창;박민용;김경환;김덕원
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권8호
    • /
    • pp.374-379
    • /
    • 2002
  • In this study, we developed a new human arm movement detection system using electrical bio-impedance method with several skin-electrodes. The correlation coefficients of the joint angle and the impedance change from human arm movement was obtained using a goniometer and impedance measurement system developed in this study. The correlation coefficients of the wrist and the elbow movements were 0.94 and -0.99, respectively. This system was applied to control a robotic arm by converting the measured impedance to joint angle to confirm the validity of the proposed system. In conclusion, we confirmed that this system can control the robotic arm according to arm movement without any limitation of movement. This system showed possibility that upper arm movement could be easily measured by impedance measurement system with a few skin-electrodes.