• 제목/요약/키워드: electrical facilities

검색결과 1,212건 처리시간 0.045초

수.변전설비의 안전실태 조사 및 대책 연구 (A Study on counterplan and safety state research of substation at flood area)

  • 배석명;김한상;김기현;방선배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.47-52
    • /
    • 2005
  • lt's a general tendency that electrical facilities of power station become a large size and increase in number because electrical facilities become big and complicated with internal industrial development and economic growth. So, electrical accidents were increased in this electrical facilities of power station. Therefore, we studied on the safety environment in power station and compared of internal and external standards. So this paper gives information which is applied to install the electrical facilities and Prevents measures against electrical accidents.

  • PDF

일반용 전기설비의 원격 전기안전 감시를 위한 수용가 설치 장치 모델 (Local Installation Device Models for Remote Electrical Safety Monitoring of Electrical Facilities for General Use)

  • 전현재;전정채;유재근
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.101-107
    • /
    • 2007
  • 대부분의 전기화재와 부재로 인한 미점검 문제가 발생하고 있는 일반용 전기설비의 효율적 안전관리를 위한 원격감시시스템의 도입을 위해서는 비용과 설치를 고려한 수용가 장치 모델의 개발이 필요하다. 본 논문에서는 일반용 전기설비의 원격 전기안전 감시를 위한 수용가 장치 모델들을 제시하였고 일반용 전기설비 설치 장소에 따른 합리적 모델을 찾기 위해 비용, 설치 및 통신 방법을 비교하였다. 그 결과 일반용 전기설비의 대부분을 차지하고 있는 주택 전기설비의 원격 전기안전 감시를 위한 합리적 모델은 저압원격검침 계량기에 안전감시 기능을 부여하는 것으로 나타났다.

환경영향 요소를 고려한 특고압 전기설비의 안전등급 평가시스템 (Assessment System of Safety Level of High Voltage Electrical Facilities Considering Environmental Factors)

  • 김동우;임용배;이기연;문현욱
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.249-254
    • /
    • 2017
  • This paper presents an assessment system of safety level of 22.9kV grade high voltage electrical facilities considering environmental factors. The assessment system was developed based on the following procedure. Firstly, assessment structure was determined by consulting standards regarding inspection and diagnosis of electrical facilities. Secondly, contents of items and sub items of assessment system were developed. Thirdly, in order to quantify the importance of the assessment system, the weight was calculated using Analytic Hierarchy Process(AHP). Lastly, assessment table of safety level was developed including environmental factors such as period of use and load factor. The developed system can evaluate the safety level of high voltage facilities in an objective way. Therefore it can be applicable to electrical safety management system based on Internet of Things(IoT).

전기철도용 유리애자 전기적 강도 해석 (Electrical Strength Analysis of Toughened Glass Stem Insulator for Electric Railways)

  • 정종욱;정진수;김영석;김선구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.263-263
    • /
    • 2008
  • This paper describes the electrical strength of a toughened glass stem insulators employed for electric railways. The broken glass stem insulators for comparison were taken at site. According to the international standards, electrical strength tests with 60[Hz] voltage and with impulse voltage were carried out to them under dry and wet condition and the results were corrected by considering the temperature and humidity factors. Based on the experimental results, the electrical strength of broken glass stem insulators was compared with those of sound ones and surface flashover characteristics were also discussed. As a result, it was confirmed that the electrical discharge is formed by bridging each end of the insulator shell. The experimental results are expected to be utilized as data for electrically identifying the failure causes of glass insulators.

  • PDF

170kV GIS용 단로기의 현장 사용 실태 조사 (A Study on the Actual Condition Investigation of the Disconnecting Switchgear of 170kV GIS)

  • 이은석;김종서;천종철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1180-1183
    • /
    • 2003
  • 170kV GIS(Gas Insulated Switchgear) is widely used in large industrial factory-electrical facilities of private use because has many benefits. But Other equipments's failures are occurred by GIS failures and give rise economic problems to user. Therefore we will examine the actual condition of the 170kV GIS-electrical facilities of private use and are able to confirm the distribution characteristic analysis of disconnecting switchgear. In this paper, we presents the actual condition investigation of the disconnecting switchgear of 170kV GIS-electrical facilities of private use by post - failure pattern, inspection method, test equipments and so forth.

  • PDF

사물인터넷 기반 전기안전 기술 및 표준화 동향 (Trends in standardization of IoT based electrical safety technology)

  • 안윤영;김성혜;정상진;강현주
    • 전자통신동향분석
    • /
    • 제35권1호
    • /
    • pp.49-59
    • /
    • 2020
  • This paper describes an IoT-based electrical safety management system for managing the electrical power distribution systems in factories or buildings and for managing private electrical devices in apartment complex. The IoT-based electrical safety management system collects IoT data from the electrical facilities or devices to provide various electrical safety services. In some cases, it uses an IoT adaptor to collect data from legacy facilities. By monitoring and analyzing the IoT data, it is possible to provide protection from and prevent electrical hazards. In addition, an IoT-based electrical safety management system can benefit from using the IoT identification system and standardized data model of the electrical facilities and devices. An IoT identification system is used to increase manageability of large-scale electrical facilities which consists of numerous IoT devices. A standardized data model is used to support interoperability. This paper also explores some international and Korean standards related to IoT-based electrical safety management.

도심에 설치된 가로등설비의 현장실태 분석 (The Field Situation Analysis of Street Lamp Which is Established in The Urban)

  • 한운기;한기붕;길형준;최충석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.117-122
    • /
    • 2003
  • Street light facilities, which are easily accessible, can be in danger of electric shock when water percolates the facilities especially in summer. In case deteriorated facilities are not checked regularly, they can cause accidents such as electric shock. We should consider regional characteristics to prevent this kind of accidents. In this paper, we analyzed the problems according to the facilities through the research on the actual conditions. We also analyzed the facilities by region and the standards by the conditions.

  • PDF

오손등급에 따른 배전기자재의 절연특성 연구 (Insulating Characteristics of the Distribution Facilities due to Grade of Salt Contamination)

  • 권태호;김동명;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1490-1491
    • /
    • 2007
  • The salt contamination on the distribution facilities, such as suspension insulator, line post insulator, lightning arrester, COS, is one of the major coastal areas because more than 90% of salt contaminated failure occurs in distribution facilities. Did to stain distribution facilities artificially according to Equivalent Salt Deposit Density(ESDD) grade. The electrical test were performed on the non-polluted and polluted facilities(ESDD B, C, D grade).

  • PDF

수용가 전기설비 사고처리 시스템 및 케이블 사고사례 연구 (The Study of Cable Fault Case and the Fault Management System of Electrical Facilities for private use)

  • 김영석;송길목;김선구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 2009
  • When happen the electrical facilities accident the one's diagnosis system of fault cause was constructed by FMEA method Cable accident cause is given by accident cause that can happen in each one's diagnosis and accident probability value. From the verification of system, the one's diagnosis system agreed well with result that analyzed actual state. Thus, the system is judged to be used effectively examine for accident cause of electrical facilities.

  • PDF

FMEA기반 전기설비 사고처리시스템 구축 및 사고사례 검증 (The Verification of Case Study and the Construction of Fault Management System of Electrical Facilities through FMEA Method)

  • 김영석;송길목;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.315-317
    • /
    • 2009
  • When happen the electrical facilities accident, the one's diagnosis system of fault cause was constructed by FMEA method. From the verification of system, the one's diagnosis system agreed well with result that analyzed actual stale. Thus, the system is judged to be used effectively examine for accident cause of electrical facilities.

  • PDF