• 제목/요약/키워드: electrical facilities

검색결과 1,212건 처리시간 0.031초

인공오손에 따른 배전기자재의 건조 및 습윤 섬락에 관한 연구 (The Study on the Dry and Wet Flashover Voltages of the Artificially Salt Contaminated Distribution Facilities)

  • 김찬영;김동명;권태호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.487-488
    • /
    • 2008
  • The dry and wet flashover characteristics on the contaminated distribution facilities was investigated. The test were carried out on the suspension insulator, line post insulator, lightning arrester, cut off switch, etc. In the dry state, the flashover voltages of facilities contaminated with B, C, D classes are similar to the non-contaminated ones. However, in the wet state, the flashover voltages of facilities contaminated with B, C, D classes are decreased. The flashover voltages of some few facilities show under the standard value. This results indicate that the high humidity may cause the flashover on distribution facilities.

  • PDF

산업오손에 따른 배전설비 절연물의 전기적 및 재료적 특성 (The Electrical and Material Characteristics of the Distribution Facilities Suffered from Industrial Pollution)

  • 김찬영;정종만;이재봉;천성남;김동명;송일근;김병숙
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.556-557
    • /
    • 2005
  • The distribution facilities, such as suspension insulator, line post insulator, lightning arrester, COS, used for long periods in the industrial pollution area were investigated. The electrical test and the material analyses were performed on the polluted and non-polluted facilities. The low frequency dry flashover voltage of polluted suspension was decreased about 8% in comparison with non-polluted one. The polluted materials turned out with the iron which came from the foundries. The polluted materials turned out with the iron which came from the foundries. This conductive materials decreased the leakage distance, resulting in reducing of electrical properties.

  • PDF

피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구 (A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester)

  • 정기석;길형준
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

예방진단기술을 활용한 GIS 고장예방대책 (The Prevention Countermeasure against Breakdown of GIS using the Preventive Diagnostic Technology)

  • 최종수;김종구;박준성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.423-427
    • /
    • 2009
  • 전력계통이 초고압, 대규모화되고 이를 구성하고 있는 대용량 전력설비들의 고신뢰도 운전이 한층 요망되고 있는 환경에서 예방진단기술을 활용한 설비운영의 중요성은 나날이 커지고 있다. GIS 등 설비의 최적화 및 효율적인 관리를 위한 예방진단기술의 정착은 현재 유지보수 비용의 절감과 설비의 안정성 향상 및 체계적인 운영을 가능하게 한다는 점에서 전력설비의 성공적인 운영에 없어서는 안 될 핵심기술로서 자리매김하고 있으며, 설비의 잔존수명예측 등 향후 예방진단기술의 발전을 위한 지속적인 연구와 관심이 뒷받침되어져야 할 것이다.

  • PDF

전기안전기술 로드맵 설계 연구 (A Study on the Roadmap Design for Electrical Safety Technology)

  • 신흥식;이재천;이병길
    • 대한안전경영과학회지
    • /
    • 제9권3호
    • /
    • pp.1-7
    • /
    • 2007
  • A roadmap for Electrical Safety Technology has been designed based on the study that has been contributed by the specialists, professors and researchers in electral safety field. The roadmap is divided into five major fields including, for instance, the electrical fire accidents roadmap. The other four roadmaps are for electrical shock accidents, electrical facilities accidents, electrical safety policies and electrical safety culture-education, respectively. Each roadmap has a purpose, a scope, and a technical characteristic. Following the roadmaps can result in significant reduction of electrical fire accidents, electrical shock accident victims and so forth. The result can also be utilized in guiding the planning and development of the future electrical safety technology.

발전 설비 감시 점검용 로봇 시스템을 위한 실내 위치 인식 시스템 설계 (Indoor Localization System for Field Robot System of Power Plant Facilities Surveillance)

  • 정창기;이재경;박준영;조병학
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2308-2312
    • /
    • 2008
  • As power plant facilities are being deteriorated, their safety is getting more important, and more routine surveillance is being required. For this purpose, this paper presents an indoor localization system for field robot system which performs the surveillance of power plant facilities instead of human workers from the viewpoint of the workers' safety and work efficiency.

공연장내 간선설비에 대한 현장실태분석 연구 (A study on the analysis of actual main line systems of entertainment places)

  • 배석명;김한상;길형준;이건호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1765-1767
    • /
    • 2003
  • The standard of living has been getting higher by reason of industrialization and economic growth. It makes people have more cultural desire(wants). Because of reasons mentioned above, a number of entertainment place and performance with high-tech is increased. This has been brought also increasing a number of electrical accident such as electrical shock, electrical fires and accidents of electrical facilities. This paper suggests technical, operational and special precautions of actual electric main line systems in entertainment places and is also written on the purpose of being applied with related provisions to designing electrical facilities, construction, check-up and inspection and maintenance for preventing further electrical disasters in entertainment places.

  • PDF

건물냉난방설비관련 전력피크관리사업 지원방안 연구 (The research on supporting method of electric peak management for building facilities of heating and cooling)

  • 양승권;이한별
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.379-382
    • /
    • 2008
  • This paper gives the support method of DSM program(power load leveling for heating and cooling facilities on building). As the national power peak load increases recently, the peak load reduction is needed. So we studied about remote controlling of power load from heating/cooling facilities on building during peak times. To adopt new DSM program, it is very important to design DSM customer supporting system. So in this paper, we dealt with the result of customer survey, and the DSM potential regarding heating/cooling facilities on building. In conclusion, the peak reduction program of heating/cooling facilities is very important and the incentive of customer should be consist of two incentive types as an installation and power reduction.

  • PDF

국제표준(IEC 62305) 도입에 따른 피뢰시스템 검사 및 유지관리에 대한 연구 (A Study on a Regulation Draft of Inspection and Maintenance for Lightning Protection Facilities based on IEC 62305)

  • 이강희;이상협;구경완
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.838-844
    • /
    • 2015
  • Latest development of ICT makes building, including houses, factories and public facilities, more intelligent and automatized. It follows that a wide variety of electric and ICT installations are adopted along with micro electronic equipments. Corresponding to such changes, the frequency of lightning increases due to the abnormal climate. The major damage by lightning surge is disconnection and malfunction of facilities. It is necessary, therefore, to make a regulation of inspection and maintenance for lightning protection facilities. This paper deals with main issues of a regulation draft of inspection and maintenance for lightning protection facilities based on IEC 62305

열병합 발전설비의 배전계통 연계시 전압변동에 관한 연구 (Study on The Voltage Variation in Power Distribution Systems Including cogeneration Facilities.)

  • 최준호;김두봉;김재철;황치우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.958-961
    • /
    • 1997
  • This Paper deals with voltage variation and voltage regulation method in power distribution systems including cogeneration facilities. In order to deliver suitable voltages to many customers at the distribution substations. In this paper, an on-line real time modified voltage regulation method is proposed. The result from a case study show that the proposed method can be practical tool for the voltage regulation in distribution systems including cogeneration facilities.

  • PDF