• Title/Summary/Keyword: electrical facilities

Search Result 1,212, Processing Time 0.04 seconds

A Study on counterplan and safety state research of substation at flood area (수.변전설비의 안전실태 조사 및 대책 연구)

  • Bae, Seok-Myung;Kim, H.S.;Kim, K.H.;Bang, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.47-52
    • /
    • 2005
  • lt's a general tendency that electrical facilities of power station become a large size and increase in number because electrical facilities become big and complicated with internal industrial development and economic growth. So, electrical accidents were increased in this electrical facilities of power station. Therefore, we studied on the safety environment in power station and compared of internal and external standards. So this paper gives information which is applied to install the electrical facilities and Prevents measures against electrical accidents.

  • PDF

Local Installation Device Models for Remote Electrical Safety Monitoring of Electrical Facilities for General Use (일반용 전기설비의 원격 전기안전 감시를 위한 수용가 설치 장치 모델)

  • Jeon, Hyun-Jae;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.101-107
    • /
    • 2007
  • In order to introduce remote monitoring system for effective safety management of electrical facilities for general use, which the most of electrical fires and non-inspection problems due to absence are generated development of local device model considering cost and installation is requested. This paper presents local device models for remote electrical safety inspection of electrical facilities for general use and in order to rational model according to installation place of electrical facilities for general use, compare and analysis cost, installation and communication method of local device models. The results show that rational model for remote safety inspection of electrical facilities located in houses, which occupy the must of electrical facilities for general use, is to give safety monitoring ability to low voltage remote meter reading(or automatic meter reading: AMR).

Assessment System of Safety Level of High Voltage Electrical Facilities Considering Environmental Factors (환경영향 요소를 고려한 특고압 전기설비의 안전등급 평가시스템)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Ki-Yeon;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.249-254
    • /
    • 2017
  • This paper presents an assessment system of safety level of 22.9kV grade high voltage electrical facilities considering environmental factors. The assessment system was developed based on the following procedure. Firstly, assessment structure was determined by consulting standards regarding inspection and diagnosis of electrical facilities. Secondly, contents of items and sub items of assessment system were developed. Thirdly, in order to quantify the importance of the assessment system, the weight was calculated using Analytic Hierarchy Process(AHP). Lastly, assessment table of safety level was developed including environmental factors such as period of use and load factor. The developed system can evaluate the safety level of high voltage facilities in an objective way. Therefore it can be applicable to electrical safety management system based on Internet of Things(IoT).

Electrical Strength Analysis of Toughened Glass Stem Insulator for Electric Railways (전기철도용 유리애자 전기적 강도 해석)

  • Jung, Jong-Wook;Jung, Jin-Soo;Kim, Young-Seok;Kim, Sun-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.263-263
    • /
    • 2008
  • This paper describes the electrical strength of a toughened glass stem insulators employed for electric railways. The broken glass stem insulators for comparison were taken at site. According to the international standards, electrical strength tests with 60[Hz] voltage and with impulse voltage were carried out to them under dry and wet condition and the results were corrected by considering the temperature and humidity factors. Based on the experimental results, the electrical strength of broken glass stem insulators was compared with those of sound ones and surface flashover characteristics were also discussed. As a result, it was confirmed that the electrical discharge is formed by bridging each end of the insulator shell. The experimental results are expected to be utilized as data for electrically identifying the failure causes of glass insulators.

  • PDF

A Study on the Actual Condition Investigation of the Disconnecting Switchgear of 170kV GIS (170kV GIS용 단로기의 현장 사용 실태 조사)

  • Lee, Eun-Suk;Kim, Jong-Seo;Cheon, Jong-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1180-1183
    • /
    • 2003
  • 170kV GIS(Gas Insulated Switchgear) is widely used in large industrial factory-electrical facilities of private use because has many benefits. But Other equipments's failures are occurred by GIS failures and give rise economic problems to user. Therefore we will examine the actual condition of the 170kV GIS-electrical facilities of private use and are able to confirm the distribution characteristic analysis of disconnecting switchgear. In this paper, we presents the actual condition investigation of the disconnecting switchgear of 170kV GIS-electrical facilities of private use by post - failure pattern, inspection method, test equipments and so forth.

  • PDF

Trends in standardization of IoT based electrical safety technology (사물인터넷 기반 전기안전 기술 및 표준화 동향)

  • An, Y.Y.;Kim, S.H.;Jeong, S.J.;Kang, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.35 no.1
    • /
    • pp.49-59
    • /
    • 2020
  • This paper describes an IoT-based electrical safety management system for managing the electrical power distribution systems in factories or buildings and for managing private electrical devices in apartment complex. The IoT-based electrical safety management system collects IoT data from the electrical facilities or devices to provide various electrical safety services. In some cases, it uses an IoT adaptor to collect data from legacy facilities. By monitoring and analyzing the IoT data, it is possible to provide protection from and prevent electrical hazards. In addition, an IoT-based electrical safety management system can benefit from using the IoT identification system and standardized data model of the electrical facilities and devices. An IoT identification system is used to increase manageability of large-scale electrical facilities which consists of numerous IoT devices. A standardized data model is used to support interoperability. This paper also explores some international and Korean standards related to IoT-based electrical safety management.

The Field Situation Analysis of Street Lamp Which is Established in The Urban (도심에 설치된 가로등설비의 현장실태 분석)

  • 한운기;한기붕;길형준;최충석
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.117-122
    • /
    • 2003
  • Street light facilities, which are easily accessible, can be in danger of electric shock when water percolates the facilities especially in summer. In case deteriorated facilities are not checked regularly, they can cause accidents such as electric shock. We should consider regional characteristics to prevent this kind of accidents. In this paper, we analyzed the problems according to the facilities through the research on the actual conditions. We also analyzed the facilities by region and the standards by the conditions.

  • PDF

Insulating Characteristics of the Distribution Facilities due to Grade of Salt Contamination (오손등급에 따른 배전기자재의 절연특성 연구)

  • Kwon, Tae-Ho;Kim, Dong-Myung;Kim, Ju-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1490-1491
    • /
    • 2007
  • The salt contamination on the distribution facilities, such as suspension insulator, line post insulator, lightning arrester, COS, is one of the major coastal areas because more than 90% of salt contaminated failure occurs in distribution facilities. Did to stain distribution facilities artificially according to Equivalent Salt Deposit Density(ESDD) grade. The electrical test were performed on the non-polluted and polluted facilities(ESDD B, C, D grade).

  • PDF

The Study of Cable Fault Case and the Fault Management System of Electrical Facilities for private use (수용가 전기설비 사고처리 시스템 및 케이블 사고사례 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.59-62
    • /
    • 2009
  • When happen the electrical facilities accident the one's diagnosis system of fault cause was constructed by FMEA method Cable accident cause is given by accident cause that can happen in each one's diagnosis and accident probability value. From the verification of system, the one's diagnosis system agreed well with result that analyzed actual state. Thus, the system is judged to be used effectively examine for accident cause of electrical facilities.

  • PDF

The Verification of Case Study and the Construction of Fault Management System of Electrical Facilities through FMEA Method (FMEA기반 전기설비 사고처리시스템 구축 및 사고사례 검증)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.315-317
    • /
    • 2009
  • When happen the electrical facilities accident, the one's diagnosis system of fault cause was constructed by FMEA method. From the verification of system, the one's diagnosis system agreed well with result that analyzed actual stale. Thus, the system is judged to be used effectively examine for accident cause of electrical facilities.

  • PDF