• Title/Summary/Keyword: electrical connections

Search Result 186, Processing Time 0.024 seconds

A Neural Network Modulars for Real-time Detection of Bad Materials (불량소자의 검지를 위한 실시간 전송 뉴로 모률라)

  • Kim, Jong-Man;Kim, Won-Sop
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.54-57
    • /
    • 2008
  • A new modular Lateral Information Propagation Networks can be implemented in a IC chip with the circuit VLSI technology for detection of bad materials. The proposed modular architecture is propagated the neural network through inter module connections. For such inter module connections, the host(computer or logic) mediates the exchange of information among modules. Also border nodes in each module have capacitors for temporarily retaining the information from outer modules. For detecting of Faulty Insulator, $4\;{\times}\;4$ neural network modules has been designed and simulation of interpolation with the designed networks has been done.

  • PDF

Study of Harmonic Influences in case of system-connections of Dispersed Substitute Energy-Generation Power Systems (분산전원의 계통연계시 고조파 영향 고찰)

  • Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.569-572
    • /
    • 2002
  • The reduction method of harmonic currents is very important, when harmonic influences of the systems connections of AC power lines with dispersed generations like solar energy and wind power generation etc, increase more and more. Which the influences of harmonic currents bring not only the drop of power quality but also many trouble occurrences of various systems. Recently, the necessity about application development of new substitute energy has gone up, and the development and practical use of dispersed power lines are proceeding now. Henceforth, a counterplan against harmonic influences must be devised for more practical use of new substitute energy. In this paper, we studied the harmonic influences and new devices for that connections and defined the calculating methods for hamonic currents of those systems.

  • PDF

Analysis of Voltage Drop and Thermal Characteristics for Poor Connections at Electrical Connector of Circuit Breaker of Small Size Pulverizer below 5.5kW (5.5kW이하의 소형분쇄기 차단기 접속부의 접촉불량에 의한 전압강하 및 열적 특성 분석)

  • Kim, Sang Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.26-31
    • /
    • 2015
  • This paper describes the characteristics of voltage drop and thermal for poor connection on electrical connector of circuit breaker in control box of small size pulverizer. In order monitor, we did the changes of RMS in voltage and temperature value with video and made normal state over $2.5N{\cdot}m$ and poor connections state below $0.2N{\cdot}m$ by screw gage. In case of voltage signal, the voltage drop was increased when the current was increased due to poor connections. In case of temperature signal, the temperature difference indicates ten times at 5A and fourteen times at 15A in the normal state. According to increase thermal energy, the insulation of electrical wiring and connector of circuit breaker can be carbonized. The results of this study will be useful to the development of preventive devices and system for electric fire by poor connection at small size pulverizer.

Lifetime Temperature Rise Model for the Degradation of Electric Connections/Contacts (도체접속부 열화에 대한 수명온도상승 모델)

  • Kim, Jeong-Tae;Kim, Ji-Hong;Koo, Ja-Yoon;Yoon, Ji-Ho;Ham, Gil-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1611-1613
    • /
    • 2000
  • In this study in order to find out the trends and the residual lifetime for electric connections/contacts using infrared image camera, "lifetime temperature rise model" is theoretically proposed on the base of "lifetime resistance model" and to prove this theory, experiments have been performed for various kinds of electric connections/contacts. Two suggestions have been builded up or the "lifetime temperature rise model" ; one is the linear relationship between the temperature rise $\Delta K$ and contact resistance, and the other is the functional relationship between the temperature of electric connections/contacts and the operating time which ascribed in the "lifetime resistance model". From the experimental results, measured values were quite similar to the theoretical value so that two suggestions in "lifetime temperature rise model" were appeared to be correct.

  • PDF

The Fire Hazard of Screwed Electric Contacts Due to Mechanical Vibration at Low Voltage Equipment

  • Choi, Chung-Seog;Kim, Young-Seok;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.18-23
    • /
    • 2005
  • There are many electrical connections in the electric apparatus and most fires due to a fault contact result from a failure or misuse of electric apparatus and installation. The fault contact happens between electrical connections by the loose and the mechanical vibration. In this paper, we have investigated thermal and electrical properties of screwed electric contacts due to the mechanical vibration. The exciter was connected to a signal generator and power amplifier that provided the vibration frequency and amplitude. The vibration, temperature and voltage data were sent to a data acquisition system (DAQ). In the case that fault contact took place, the arc happened between the screwed electric contact and electric wire, heat due to the arc was transmitted to the adjacent insulators, for which the oxide could be generated more. In addition, a spark was generated and the insulator began to melt. Thus, the possibility of electrical fire became the highest in this case. Finally, when the fault contact takes place due to vibration, the hazard of an electric accident is very high.

The Heating of Cu-oxide and Arc Properties according to Electrical Poor Contact (전기적 불완전 접촉에 따른 동산화물의 발열 및 아크 특성)

  • Kim, Wansu;Park, SangJune;Hwang, DongHyun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.15-20
    • /
    • 2019
  • As industry is progressing and standards of living are improved, the demand of electrical energy is expected to grow 8-9% annually. Therefore, the importance of electrical fire prevention technology with the ability of the power supply is being emphasized. According to the statistics of fire in Korea, fire occurred about 45,000 cases annually, and electrical fire possessed about 20%. The electrical fire by poor contact has increased gradually, can be connected as great fire to secondarily induce short circuit and earth fault. Then analysis of heating causes of electrical connections between copper and copper alloy is needed. Also, detection and analysis algorithm of oxide at copper alloy are necessary. In this research, in order to understand the characteristics of oxide growth with rising resistance and heating, it is demonstrated that the oxide at electrical connections can cause fire due to arcing.

Detection and Identification of the Series Arc in an Indoor Wiring System (옥내 배선계통에서 직렬 아크의 검출과 판별)

  • Kim, Woo-Hyun;Wang, Guoming;Kil, Gyung-Suk;Ji, Hong-Keun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.412-416
    • /
    • 2018
  • Most series arcs lead to electrical fires that cannot be interrupted by circuit breakers, because the arc's current is outside the breaker's operating range. In this paper, experiments were conducted on the detection and identification of series arcs to prevent electrical fires. Plugs and outlets specified in KS C 8305 were deteriorated to replicate arc faults commonly found in fields. The characteristics of series arcs resulting from various types of loose connections were determined by analyzing the frequency spectra and phase distributions of detected arc pulses. The results showed that the simulated arc defects used in this study were more similar to actual arc phenomena than the existing arc generator specified in UL 1699. In addition, loose connections, such as wire-wire, terminal-wire, and outlet-plug, can be identified by phases of $0^{\circ}$, $180^{\circ}$ and $360^{\circ}$, respectively. These phases can be detected by a band pass filter with a frequency range of 5~10 MHz, which can be used as the trip signal for circuit breakers.

A Modular Design of the Lateral Information Propagation Neural Networks (용이한 확장을 위한 측방향정보전파 신경회로망의 모듈라 설계)

  • Kim, Sung-Won;Kim, Hyong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2206-2208
    • /
    • 1998
  • The modular Lateral Information Propagation Networks(LIPN) has been designed. The LIPN has shown to be useful for interpolation of information[3]. The problem is the fact that only the small number of nodes can be implemented in a IC chip with the circuit VLSI technology. The proposed modular architecture is for enlarging the neural network through inter module connections. For such inter module connections, the host(computer or logic) mediates the exchange of information among modules. Also border nodes in each module have capacitors for temporarily retaining the information from outer modules. The LIPN with $4{\times}4$ modules has been designed and simulation of interpolation with the designed LIPN has been done.

  • PDF

An Application Study of the Closed Type Section Insulators to the High Speed Catenary System (Closed Type 절연구분장치 적용에 관한 연구)

  • 최규형;이기원
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.498-502
    • /
    • 2002
  • Section insulators are indispensible devices for the electric railways, which divide electrical connections between the trolley lines without losing mechanical connections, and this means that they should have both good electrical insulation performance and mechanical performance for pantograph interaction. This paper reviews some technical aspects of the several type section insulators and makes analysis of difficulties during operation. The closed type section insulators are proposed for newly electrified railways, because they have good mechanical and electrical performances for high speed trains up to 200[km/H]. Technical specifications of closed-type section insulators based on survey of the advanced technologies are provided, and also the neutral section configuration method which might be the best solution for newly electrified railways in Korea of 200km/H speed.

  • PDF

Dynamic Analysis of Rotor Eccentricity in Switched Reluctance Motor with Parallel Winding

  • Li, Jian;Choi, Da-Woon;Cho, Yun-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.85-87
    • /
    • 2008
  • This paper presents dynamic characteristics in Switched Reluctance Motor (SRM) with rotor eccentricity and proposes the reduction method of rotor eccentricity effects by the different winding connections. These characteristics investigations are computed by 2D transient magnetic FEM analysis coupled with external circuits. The radial and unbalance magnetic force in the stator, which is the main exciting force of the vibration, is calculated using Maxwell stress method and compared with the performance characteristics according to the serial and parallel connections of windings. The influence of winding method counteracting unbalance forces on the rotor vibration behavior is estimated by the current waveforms of the paralleled paths under rotor eccentricity.

  • PDF