• Title/Summary/Keyword: electrical connection

Search Result 1,132, Processing Time 0.024 seconds

Design of Neurofuzzy Networks by Means of Linear Fuzzy Inference and Its Application to Software Engineering (선형 퍼지추론을 이용한 뉴로퍼지 네트워크의 설계와 소프트웨어 공학으로의 응용)

  • Park, Byoung-Jun;Park, Ho-Sung;Oh, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2818-2820
    • /
    • 2002
  • In this paper, we design neurofuzzy networks architecture by means of linear fuzzy inference. The proposed neurofuzzy networks are equivalent to linear fuzzy rules, and the structure of these networks is composed of two main substructures, namely premise part and consequence part. The premise part of neurofuzzy networks use fuzzy space partitioning in terms of all variables for considering correlation between input variables. The consequence part is networks constituted as first-order linear form. The consequence part of neurofuzzy networks in general structure(for instance ANFIS networks) consists of nodes with a function that is a linear combination of input variables. But that of the proposed neurofuzzy networks consists of not nodes but networks that are constructed by connection weight and itself correspond to a linear combination of input variables functionally. The connection weights in consequence part are learned by back-propagation algorithm. For the evaluation of proposed neurofuzzy networks. The experimental results include a well-known NASA dataset concerning software cost estimation.

  • PDF

Fault Diagnosis Device for Fire Prevention of the Resistance Heating Type three-Phase Electric Heater (3상 저항가열식 전기히터의 화재예방을 위한 결함 진단장치)

  • Lee, Mun-Hyung;Kim, Chan-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1669-1674
    • /
    • 2017
  • In this study, We have discussed the development of a diagnostic device to detect and prevent electrical fire due to the arc caused by contact failure and partial disconnection at the connection part of the three-phase electric heater wiring used in the industrial field. The arc caused by contact failure and partial disconnection at the connection part of the electric heater shows a change in the current effective value. Therefore, it is possible to determine whether there exists a defect by analyzing the current unbalance factor and the number of current fluctuations with the diagnostic apparatus. The three-phase unbalanced heater is considered to be capable of determining defects through periodic measurement and trend analysis of the current unbalance factor. It is also expected that this device can be used not only for electric heaters but also for detection of defects in wiring and connections of electrical equipment having a characteristic of constant load current.

Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator (동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어)

  • Song Seung-Ho;Kim Sung-Ju;Hahm Nyon-Kun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.

An Analysis on Price Limits of Imported Power via Northeast Asian Power System Ties

  • Chung, Koo-Hyung;Kim, Balho H.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.342-345
    • /
    • 2007
  • This paper presents an engineering approach to derive the optimum price levels of transacted power. In this paper, with the assumption that power import is possible through the system connection in Northeast Asia regions, the upper price limit of imported power deserving economic efficiency was derived with respect to the time and amount of power import. The proposed approach was demonstrated based on the data from the National Power Development Planning in 2004 with the WASP model.

Improvement Analysis of The Voltage Stability of STATCOM by Scaled Hardware Model Test. (축소모형에 의한 STATCOM의 전압안정도 개선효과 분석)

  • Han, Byung-Moon;Kim, Hee-Jung;Park, Ji-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2079-2081
    • /
    • 1998
  • This paper describes an experimental results to analyze the dynamic characteristics of STATCOM, which is connected to the ac system for improving the voltage stability. The experimental results confirms that the scaled model for STATCOM operates correctly by the conceived control algorithm and properly compensates and regulates the bus voltage at the common connection point.

  • PDF

Development of a resistive superconducting fault current limiter (저항형 초전도 한류기의 개발)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Hyun, Ok-Bae;Hwang, Jong-Sun;Jeong, Dong-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.141-144
    • /
    • 2002
  • We present current limiting properties of 1.2kV/70A superconducting fault current limiter based on YBCO thin films. This is consisted of 6 wafers (3 parallel ${\times}$ 2 serial connection) with 4 inch-diameter YBCO thin film. The quench current Iq of the switching elements vary between 33.9 and 35.6 A. Within the difference of 0.5 A in the sum of quench current Iq in two stacks, the serial connection of the stacks showed the simultaneous quench behavior in applied power of 1.2 kV /70 A.

  • PDF

Development of a Non-contacting Capacitive Sensor for Measurement of ${\mu}{\textrm}{m}$-order Displacements (마이크로미터 변위 측정을 위한 비접촉식 전기용량 센서 개발)

  • 김한준;이래덕;강전홍;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.768-771
    • /
    • 2001
  • Non-contacting capacitive sensor, based on principle of the cross capacitor, for measuring of $\mu\textrm{m}$-order displacements have been fabricated and characterized. To overcome disadvantages of the existed capacitive sensors of parallel type with 2-electrodes and 3-electrodes, the developed new sensor was designed to have 4-electrodes, two of them used high and low electrode the other two used as guard electrodes, on a sapphire plate with diameter 17 mm and thickness 0.7 mm, and are symmetrically situated with a constant gap of 0.2 mm between the electrodes. This sensor can be used for measuring the distance between sensor and target not only the metallic but also non-metallic target without ground connection.

  • PDF

High Voltage Pulse Generator Using Power Semiconductor Switcher (전력용 반도체 소자를 이용한 새로운 고전압 펄스발생회로)

  • Baek, Ju-Won;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.408-415
    • /
    • 2001
  • Using power semiconductor switches such as IGBTs, diodes and L-C circuits, novel repetitive impulse voltage generator is developed. In the presented circuits, high voltage pulse is generated by series-connection of capacitors and IGBTs. Therefore, the high voltage pulse is obtained by circuit configuration without any high voltage pulse transformer and high voltage dc source. Especially, the proposed circuit can operate up to several kHz and have high reliability and longer life than conventional ones. In also gives voltage balance of IBGTs automatically. So, the difference of characteristics of IGBTs and drive signal does not cause severe problems. To verify the proposed circuit, 20kV and 300A pulse generator is manufactured and tested.

  • PDF

Analysis and Compensation of PCC Voltage Variations caused by Wind Turbine Power Fluctuations

  • Im, Ji-Hoon;Song, Seung-Ho;Kang, San
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.854-860
    • /
    • 2013
  • The voltage variation problem at the point of common coupling (PCC) in a grid-connected wind turbine is investigated. The voltage variation problem is one of the most frequent power quality issues for the grid connection of large amounts of input power in a weak grid. Through the simplified modeling of the wind turbine and power network, the magnitude of PCC voltage variation is calculated by using the equivalent circuit parameters and output power of the wind turbine. The required amount of reactive power that can compensate the voltage variation is also presented analytically by using the vector diagram method. The proposed calculation and compensation method of the PCC voltage variation is verified by computer simulations and experiments.

New Simulation Method of Flashover Rate by Connection of EMTP and MATLAB

  • Seo, Hun-Chul;Han, Joon;Choi, Sun-Kyu;Lee, Byung-Sung;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.602-608
    • /
    • 2016
  • Because of the random characteristics of lightning, the Monte Carlo method is applied to estimate the flashover rate due to lightning, however, the simulations using previous methods are difficult to both beginner and expert in power corporations. Therefore, this paper proposes the new and easy method to simulate the flashover rate by connection of electromagnetic transients program (EMTP) and MATLAB. The magnitude of a lightning strike is based on a curve measured in the field, while the classification of direct and indirect lightning depends on the striking distance. In a Korean distribution system, the flashover rate induced by lightning is simulated using proposed method. Simulations of the footing resistance according to the existence of an overhead ground wire (OHGW) are performed and the simulation results are discussed. The simulation results are compared with findings obtained with the IEEE Flash 2.0 program.