Investigation of a Method for RF Circuits Analysis Based on Electromagnetic Topology

  • Park, Yoon-Mi;Chung, Young-Seek;Cheon, Chang-Yul;Jung, Hyun-Kyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.396-400
    • /
    • 2009
  • In this paper, electromagnetic topology (EMT) was used to analyze the electromagnetic compatibility (EMC) of RF circuits including passive and active components. It is difficult to obtain usable results for problems relating to electromagnetic coupling in complex systems when using conventional numerical or experimental methods. Thus it is necessary to find a new methodology for analyzing EMC problems in complicated electromagnetic environments. In order to consider the nonlinear characteristics of active components, a SPICE diode model was used. A power detector circuit and the receiver circuit of a radio control (RC) car were analyzed and experimented in order to verify the validity of this method.

A Decision Method for the Optimal Insertion Resistance of a Superconducting Fault Current Limiter with Reduction of an Asymmetric Fault Current (비대칭 고장전류 저감 기능을 갖는 초전도 한류기의 최적 저항 결정 방안)

  • Kim, Chang-Hwan;Kim, Kyu-Ho;Rhee, Sang-Bong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.57-63
    • /
    • 2015
  • Fault currents characteristics contain decaying DC offset. First cycle peak value of fault currents is higher than steady-state fault current value. These characteristics can affect the operation of protective device. To reduce the asymmetric fault current, the method using a series connection of two hybrid-type Superconducting Fault Current Limiter(SFCL) components, an auxiliary SFCL and a main SFCL, has been proposed. The auxiliary SFCL limits the first half cycle fault current, while main SFCL limits the steady state fault currents. This paper proposed a decision method of the optimal insertion resistance of auxiliary and main SFCL components. To verify the effectiveness of proposed scheme, the various simulations are performed by using Electromagnetic Transient Program(EMTP).

Analysis of harmonics and torque ripples for the BLDC operations (BLDC 모터의 운전시의 고조파 및 토오크 리플 해석)

  • Kim, Yoon-Ho;Yoon, Byung-Do;Hong, Ik-Pyo;Cho, Byung-Guk
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.877-879
    • /
    • 1993
  • In this paper, the voltage control is applied to the adjustable speed operation of BLDC motor with the trapezoidal back emf waveform. Torque chrateristics of BLDC are investigated through Fourier analysis when the pulse width modulation inverter is applied. Also, this paper consisders the theoretical problem of eliminating some harmonic components in inverter output waveforms, which, in turn, allows to remove some ripple components. Numerical technique is applied to solve the transcendental equations of the problem by the computer.

  • PDF

Minimal Cut Set of Electric Power Installations using Fault Tree Analysis (FTA를 이용한 수변전설비의 최소절단집합 도출)

  • Park, Young-Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.41-46
    • /
    • 2017
  • In this paper, from making an electrical fire which is thought to be the most damaging among potential dangers as a top event, minimal cut sets (MCS) about it were analyzed. For this, components of a power substation were classified into 15 items. Failure rates and modes were extracted based on Korea Electrical Safety Corporation, IEEE Gold Book, and RAC. To analyze the top event (an electrical fire), main events were assorted into "safety devices for overcurrent" and "ampere meter of detecter". Failure of components was divided into failure of VCB, COS, and MCCB. A fault tree was composed of 3 AND gate, 5 OR gates and 17 basic events. Overlapped events among the basic events are things which occur from relevant components. They were attached to the tree by distinguishing identifiers. In case of FT, two minimal cut sets of "IO_METER", "MF_METER", "DO_MCCB" and "IO_METER", "MF_METER", "DO_VCB" take 46% of electrical fires. Therefore, about basic events which are included in the top two minimum cut sets, strict control is necessary.

Floating Voltage Stacked LED Driver for Low Voltage Stress and Multi-channel Current Balancing (저 전압스트레스 및 다채널 전류 평형을 위한 Floating 전압 스택형 단일스위치 LED 구동회로)

  • Hwang, Won-Sun;Hwang, Sang-Soo;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.122-129
    • /
    • 2015
  • In this study, we propose a low voltage stress and cost-effective light emitting diode (LED) driver capable of multi-channel current balancing. Conventional LED drivers require as many boost converters as the number of LED channels, whereas the proposed LED driver requires only one buck converter and several balancing capacitors instead of several expensive boost converters. Additionally, while the components of the boost converter have high voltage stress and depend on the LED driving voltage, components of the proposed driver have about one-half of the voltage stress across all components. The proposed driver exhibits high reliability and cost effectiveness because it only uses few DC blocking capacitors with no additional active devices to balance the current of multi-channel LEDs. The proposed driver exhibits high reliability and cost effectiveness. The validity of the proposed driver is confirmed through a theoretical analysis. An explanation of the design considerations and experimental results were obtained using a prototype applicable to a 46" LED-TV.

An Accurate Model of Multi-Type Overcurrent Protective Devices Using Eigensystem Realization Algorithm and Practice Applications

  • Cheng, Chao-Yuan;Wu, Feng-Jih
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.9-19
    • /
    • 2016
  • Accurate models of the characteristics of typical inverse-time overcurrent (OC) protective devices play an important role in the protective coordination schemes. This paper presents a novel approach to determine the OC protective device parameters. The approach is based on the Eigensystem Realization Algorithm which generates a state space model to fit the characteristics of OC protective devices. Instead of the conventional characteristic curves, the dynamic state space model gives a more exact fit of the OC protective device characteristics. This paper demonstrates the feasibility of decomposing the characteristic curve into smooth components and oscillation components. 19 characteristic curves from 13 typical and 6 non-typical OC protective devices are chosen for curve-fitting. The numbers of fitting components required are determined by the maximum absolute values of errors for the fitted equation. All fitted equations are replaced by a versatile equation for the characteristics of OC protective devices which represents the characteristic model of a novel flexible OC relay, which in turn may be applied to improve the OC coordination problems in the sub-transmission and distribution systems.

A Study on the Maintenance Plan Considering Maintenance Cycle of Wind Turbine Component (각 컴포넌트 유지보수 주기를 고려한 풍력발전 설비의 유지보수 계획에 관한 연구)

  • Lee, Yun-Seong;Shin, Jun-Hyun;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.39-45
    • /
    • 2013
  • Wind power is one of the fastest growing renewable energy sources. In these days, wind turbine shifts from onshore to offshore because the offshore wind farm has a abundant wind resource. However, offshore wind turbine is not easy to access, it has a long downtime when the failures of the wind turbine component occur. Therefore, the appropriate wind turbine maintenance plan is required to meet the economic and reliability of the components. This paper proposes the maintenance planning method based on the RCM(Reliability Centered Maintenance) to determine an economical maintenance cycle to satisfy the appropriate reliability of the wind turbine components. In order to compare the proposed method with the conventional RCM method, critical components are selected in the case study because they have a long downtime and a large amount of total cost.

Bidirectional DC-DC Converter Based on Quasi-Sepic for Battery Charging System

  • Zhang, Hailong;Chen, Yafei;Kim, Dong-Hee;Park, Sung-Jun;Park, Seong-Mi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_1
    • /
    • pp.139-147
    • /
    • 2020
  • In order to satisfy the voltage levels of the low voltage battery side and high voltage DC bus, a high voltage gain with bidirectional operation is required. In this system, the cost effectiveness of the design is a critical factor; therefore, the system should be designed using a small number of components. This paper propose a novel bidirectional converter composed with a quasi-sepic and switched-indictor network. The proposed converter consists a small number of components with a high voltage gain ratio. Detailed analysis are made with respect to the operating mode, number of components, voltage and current ripple and efficiency. To verify performance of the proposed converter, simulation was performed is this paper. The simulation results are shown to verify the feasibility and performance of the proposed bidirectional converter.

Analysis and Design considerations of LLC Resonant Converter Including Parasitic Components

  • Lee, Byoung-Hee;Kim, Chong-Eun;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.511-513
    • /
    • 2008
  • Since conventional analysis of LLC resonant converter has a limit to explain a practical operation of LLC Resonant Converter, LLC resonant converter designed by conventional analysis can not regulate output voltage in several conditions. To solve this problem, analysis and design of LLC resonant converter including parasitic components is proposed. Experimental results are shown to confirm the feasibility of the proposed method.

  • PDF

A Study on the Digital Distance Relaying Techniques Using Kalman Filtering (칼만필터링에 의한 디지털 거리계전 기법에 관한 연구)

  • 김철환;박남옥;신명철
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.3
    • /
    • pp.219-226
    • /
    • 1992
  • In this study, Kalman filtering theory is applied to the estimation of symmetrical components from fault voltage and current signal when it comes to faults with the power system. An algorithm for estimating fault location accurately and quickly by calculating the symmetrical components from the extracted fundamental voltage phasor and current phasor is presented. Also, to confirm the validity of digital distance relaying techniques using Kalman filtering, the experimental results obtained by using the digital simulation of power system is shown.

  • PDF