• 제목/요약/키워드: electric wave

검색결과 794건 처리시간 0.026초

공기압을 이용한 전기설비 침수 방지 장치 개발에 관한 연구 (The development for flooding prevention apparatus of electrical equipment using air pressure)

  • 김기현;전현재;이상익;배석명;이재용
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.281-284
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment(Pad-mounted Transformer and Switch). In case of installing the power equipment at flood danger territory, we are necessary to the product development, the product is that water does not come in the inside the power equipment. Product of pressure maintaining are established on the basic frame and sensor operates at the flooding occurrence and is maintained a shutting tightly structure and it is a method. The product which is produced the reliability of the product it confirmed a flooding yes or no from the condition which puts in the water tank and it verified. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation and a security of the flood protection product.

  • PDF

환자감시를 위한 모듈형 호흡 시스템의 구현 (The implementation of modular respiratory system for patient monitoring)

  • 박종억;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.503-506
    • /
    • 2001
  • 심전도 감시장치(electro-cardiography monitoring system)에 대한 연구는 국내외적으로 활발하게 이루어지고 있으나, 국내의 경우 환자 상태를 감시하는데 있어 중요한 요소인 호흡(respiration)에 관한 연구는 다소 미흡한 민이 있었다. 이번 연구는 환자의 상태를 감시하는데 있어 심전도, 혈압(brood pressure), 체온(temperature)과 더불어 중요한 요소로 여겨지는 호흡에 대한 감시장치로, 호흡 시 신체의 임피던스 변화를 이용하여 시스템을 구현함으로써, 심전도 측정과 병행하여 사용할 수 있는 장점이 있다. 특히, 임피던스를 이용한 환자감시장치의 경우 중추신경 마비 둥의 원인에 의한 무호흡 감지에 효과적으로 응급실 등에서 유용하게 사용된다. 구현된 시스템은 아날로그 부와 디지털 부의 잡음간섭 린 환자의 안전을 도모하기 위해 회로를 전기적으로 분리하여 설계하였다. 아날로그 부의 구성은 고주파 신호를 발생하는 정현파 발생부, 반송파로부터 인체의 임피던스 변화성분을 추출하고 증폭하는 증폭부, 기저대역으로 변환하기 위한 복조 및 아날로그 필터부로 구성되어 있다. 디지털 부는 아날로그-디지탈 변환기 및 디지털 필터, 생체정보 추출부로 구성되어있다. 본 연구에서 구현된 시스템은 심전도 감시장치의 전극을 공용으로 사용할 수 있도록 구성되었으며, 호흡 감시장치에 대한 기반기술 획득을 통해 다기능환자감시장치의 개발에 바로 응용 될 수 있다.

  • PDF

탄소섬유강화 복합재료의 전자파 차폐특성 (Electromagnetic Interference Shielding of Carbon Fibers-Reinforced Composites)

  • 심환보;서민강;박수진
    • 폴리머
    • /
    • 제24권6호
    • /
    • pp.860-868
    • /
    • 2000
  • 본 연구에서는 섬유등급, 배향각 및 적층방법을 달리하여 제조한 탄소섬유강화 복합재료의 제조변수에 따른 전자파 차폐 특성에 관하여 고찰하였다. 그 결과, 탄소섬유강화 복합재료의 전자파 차폐효과는 섬유의 배향각도에 크게 좌우되었다. 특히 0$^{\circ}$의 배향각에서는 섬유의 등급에 따른 영향을 나타내었으며, 동일한 탄소섬유라 할지라도 배열방향에 따른 전기적 성질의 변화, 즉 전기적 이방성이 클수록 차폐효과는 커졌다. 각각의 적층방법에 따라 제조된 모든 시편은 83~98%의 차폐효과를 나타내었으나, 대칭구조와 비대칭구조에서는 적층각도가 커짐에 따라 차폐효과가 소폭 감소하였다. 그러나 반복구조에서는 위의 두 가지 구조와는 다른 경향을 나타내었으며, 특히 90$^{\circ}$ 반복구조의 경우 측정 주파수 전 영역에 걸쳐 90% 이상의 차폐력을 나타내었다.

  • PDF

정상군 및 허혈성 심질환 환자군에서의 심자도 파라미터 비교 (Comparison of Magnetocardiogram Parameters Between a Ischemic Heart Disease Group and Control Group)

  • 박종덕;허영;진승오;전성채
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권11호
    • /
    • pp.680-688
    • /
    • 2005
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. We have observed electrophysiological phenomena of the heart by measuring components of magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUD) system. We have analyzed the possibility and characteristics of MCG parameters for diagnosis of ischemic heart disease. A technique for automatic analysis of MCG signals in time domain was developed. The methods for detecting the position, the interval, the amplitude ratio, and the direction of single current dipole were examined in the MCG wave. The position and interval parameters were obtained by calculating the gradients of a envelope curve which could be formed by the difference between the maximum and minimum envelope of multi-channel MCG signals. We show some differences of the frequency contour map between the normal MCG and the abnormal (ischemic heart disease) MCG. The direction of single current dipole can be defined by rotating the magnetic field according to Biot-Savart's law at each point of MCG signals. In this study, we have examined the direction of single current dipole from searching for the centroids of positive and negative magnetic fields. The amplitude ratio parameters for measuring 57 deviation consisted of A$_{T}$/A$_{R}$ and other ratios. and We developed a new analysis method, which is based on the frequency contour map of electromagnetic field. Using theses parameters, we founded significant differences between normal subjects and ischemic patients in some parameters.

3차원체의 MT응답에 미치는 층상대지의 효과 (An Effect of Layered Earth on Magnetotelluric Responses of Three-Dimensional Bodies)

  • 김희준;홍철훈
    • 자원환경지질
    • /
    • 제27권5호
    • /
    • pp.491-498
    • /
    • 1994
  • 2층구조 대지속에 존재하는 유한 크기의 불균질체로 인한 지자기 지전류 (MT) 응답을 적분방정식법으로 계산하였다. 적분방정식은 입사전자장과 3차원물체 내부의 산란전류를 층상대지에 적합한 전기적 텐서 그린함수를 통하여 연결시킨다. 본 논문에서는 3차원체의 MT응답에 미치는 표층과 기반층의 영향에 대하여 검토하였다. 표층은 탐사대상물의 검출을 방해하는 효과를 가지며 그 효과는 표층의 전기비저항이 높을 때보다 낮을 때가 더 뚜렷하다. 한편 기반은 상층의 3차원체에 인한 MT이상을 높이는 효과를 가져올 수도 있다. 전기비저항이 높은 기반이 존재하면 물체에 의한 전류의 미소변동은 보다 전기비저항이 낮은 상층에 한정되는 경향이 있다.

  • PDF

EEG, fMRI, EAV 및 SQUID장치(裝置)를 이용(利用)한 기공현상(氣功現狀) 측정(測定) (The Studies on Qigong state Using EEG, fMRI, EAV and SQUID Measurments)

  • 정찬원;최찬헌;윤유식;소철호;나창수;장경선
    • Korean Journal of Acupuncture
    • /
    • 제21권2호
    • /
    • pp.1-28
    • /
    • 2004
  • Objectives : Human physiological changes in the state of qigong has been measured using EEG(Electroencephalography), functional MRI(functional Magnetic Resonance Image), EAV(Electro-Acupuncture according to Voll) and SQUID(Superconducting Quantum Interference Device) measurements. Methods & Results : EEGs were measured to study the differences between Qigong masters and Qi receiver on the changes of EEG. During Qigong, an alpha waves were increased. The power spectra indicate that the peak frequency of alpha waves increased during Qigong. Qi receiver's EEG signals seemed to affected by the state of himself. Brain activation did not observed when qigong master concentrates the Qi at Laogong(P8). But a localization of fMRI signal in the sensory cortex was observed by electric acupuncture stimulation at Laogong(P8). Five phase deviation of EAV were clearly changed in the both cases of Qigong master and Qi receiver. When a Qigong master concentrates the Qi at Yintang, Laogong(P8), Qihai(CV6) meridian points during Qigong state, the change of magnetic field around acupoints Yintang, Laogong points has been measured using 40-Channel DROS-SQUID apparatus. After smoothing process of the continuously measured magnetic signal around acupoints for a few minutes, we could observe that a series of peaks, magnitude of -1.0~2.5pT appeared. But there was no significant difference in changes of magnetic signal around acupoints. Physical signals of magnetocardiogram has been measured by using 2-Channel DROS SQUID(Magnetocardiogram). Physical signals of magnetocardiogram were clealy changed at the ST segments after S-wave when qigong master concentrates the Qi.

  • PDF

밀리미터파 레이다 시스템을 이용한 전력선 검출

  • 강금실;용상순;강성덕;김정아;장영준
    • 항공우주기술
    • /
    • 제3권1호
    • /
    • pp.242-250
    • /
    • 2004
  • 군용뿐만 아니라 상업용으로 헬리콥터의 사용 빈도가 높아지면서, 무엇보다 헬기의 안정성이 가장 중요한 요소가 되었다. 단순히 조종사에 의한 시계 비행을 할 경우 야간 운항이 불가능하며 안개, 눈, 비 등의 기후 조건에서는 매우 불안전하다. 그리고 주간 비행 중에도 전선과 같은 장애물로 인한 사고가 발생하고 있다. 그러므로 헬기의 안전운항을 위해서는 단순한 시계 비행에서 벗어나 장애물 탐지 시스템을 이용한 자동항법 개념을 도입해야 한다. 자동항법을 위한 장애물 탐지 시스템은 안개, 눈, 비 등의 기후 조건하에서 주간 및 야간에도 정상적으로 동작해야 한다. 본 논문에서는 밀리미터파 레이다 시스템을 이용하여 전선 장애물의 탐지 기술 획득을 위한 기초 연구를 수행하였다. 서론에서는 헬기 운항에 장애가 되는 요소들을 탐지하기 위한 여러 방법들에 대해서 살펴봤다. 본론에서는 밀리미터파를 이용한 장애물 탐지 시스템과 실험 장치에 대해서 다루고 결론에서는 실험 결과 및 향후 연구 방향에 대해서 다루고 있다.

  • PDF

CLN-PZT 세라믹스의 전기, 광학 특성에 관한 연구 (A Study on the Electrical and Optical Characteristics of CLN-PZT Ceramics)

  • 강원구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.799-801
    • /
    • 1988
  • This paper was studied on the effects of Ca-La-Nb substitution and Zr/Ti ratio variation to Pb(Zr, Ti)$O_3$ system on structural, electrical, optical and sound level characteristics in order to develope the piezoelectric and electrooptic ceramic devices. Also the specimens were prepared by the two stage sintering technique. The molecular formular was X($CaO{\cdot}1/4La_{2}O_{3}{\cdot}1/4Nb_{2}O_{5}){\cdot}(1-X)Pb(Zr_{Y}Ti_{1-Y})O_{3}$(x=100X, y=100Y), and the variation of x was $6{\sim}12$, y was 60${\sim}$49 and second stage sintering time was 20${\sim}$40 hours. The experimental results obtained from this study are as follows : 1. The density was decreased, the grain size was increased according to increase of Ca-La-Nb substitution. 2. The crystal structure was rhombohedral in composition 6/60/40, and the crystal structure was tetragonal and cubic according to increase of Ca-La-Nb substitution. 3. The Ca substitution of PZT system enhanced the sintering property. The Pb site vacancy resulting from the substitution of La-Nb increased the dielectrical constant, the piezoelectric charge constant, the dielectric loss and decreased the coercive field. 4. The resistivity of PZT system which has the P type conduction mechanism increased according to substitution of La-Nb because of the substituent acting as donor. 5. The PZT ceramics varied from ferroelectric substance according to increase of Ca-La-Nb substituent. The coercive field and saturation remanent polarization decreased, and at last straight line according to increase of La-Nb substitution. 6. The amount of Ca-La-Nb substitution to improve the light transmittance of speciment was 10 mol%, the Zr/Ti ratio was 49/51, and the second stage sintering time was 40 hours. 7. According to Ca-La-Nb substitution, the specimens was to be transparent. The 7.5/51/49 specimen was suitable for transparent sound vibrator because it had 58% light transmittance (thick 0.2[mm], wave length 700[mm]) and 48% electromechanical coupling factor.

  • PDF

고효율 평형 전력 증폭기 (High Effciency Balanced Power Amplifier)

  • 신헌철;김갑기;이창식;이종악
    • 한국전자파학회논문지
    • /
    • 제8권4호
    • /
    • pp.323-331
    • /
    • 1997
  • 본 논문에서 고효율 평형 증폭기는 기본적으로 두 개의 FET와 입력 전력 분배기, 출력 전력 결합기, 입력 정합회로, 출력 정합회로, 2차 고조파 상호 연결 회로로 구성된다. 2차 고조파 상호 연결 회로는 FET출력 정합회 로의 출력 단자사이에 끼워지므로 2차 고조파 정재파는 두 FET 출력사이에서 발생된다. 전기벽 종단은 단락 회로 종단과 등가이고 고효율을 얻기 위해 펼요한 FET 출력 종단 조건 실현이 가능하다. 실험 결과 증폭기는 1.75 G GHz에 맞추어 설계, 제작되었고 실험 결과 2차 고조파 성분은 기본파에 비해 약 20 dBc 이상을 나타냈고 왜곡 이 1% 이하이다. 또한 약 3W의 출력을 얻었고, 이 출력점에서 75 %의 효율을 얻을 수 있었다. 증폭기의 입력, 출력 VSWR은 각각 1. 27, 1.18을 나타내었다.

  • PDF

반응성 메조겐을 이용한 폴리머 광도파로 편광 변환기 (Integrated Optical Wave Plates Fabricated by Incorporating Reactive Mesogen in Polymer Waveguide)

  • 도현수;추우성;오민철
    • 한국광학회지
    • /
    • 제22권5호
    • /
    • pp.219-222
    • /
    • 2011
  • 광도파로에 일체형으로 제작 가능한 편광 변환기는 다양한 기능의 광집적회로를 구성하기 위한 필수적인 부품이다. 반응성 메조겐은 액정디스플레이의 파장판 제작을 위하여 널리 사용되는 재료이며, 본 연구에서는 반응성 메조겐과 폴리머 광도파로를 이용하여 집적형 편광 변환기를 제작하였다. 반응성 메조겐과 액정을 혼합한 용액을 광도파로에 직교하게 형성된 홈에 삽입하고 전계를 인가하여 액정 분자를 특정 방향으로 정렬 한 뒤 UV 를 조사하여 RM 분자를 경화시켜주면 광도파로를 가로지르는 파장판을 형성할 수 있다. 파장판의 특성은 두께를 결정짓는 홈의 폭과 액정 분자의 정렬 상태 및 복굴절 크기에 의해 결정된다. 폴리머 광도파로의 중앙에 제작된 편광변환기는 1550 nm 파장에서 편광변환효율이 90 %에 이르게 됨을 확인하였다.