• 제목/요약/키워드: electric wave

검색결과 794건 처리시간 0.027초

강유전특성 측정장치의 연구개발 (A study on measurement apparatus for ferroelectricity in ferroelectrics)

  • 이창헌;강대하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1317-1319
    • /
    • 1997
  • This paper is to study and develope a measurement apparatus for ferroelectricity. The apparatus consists of wave generation part, high voltage amplifier part, measurement part, data acquisition part and the related controll circuits. Single or double excitation wave is digitalized and sent to the external RAM of wave generation part by personal computer. These datas saved in the RAM are converted to analog excitation wave through D/A converter. The frequency of excitation wave is depend on the read-out speed of the RAM by clock pulse. Such generated wave is applied to high voltage amplifier as a input voltage. The output of high voltage amplifier is applied to ferroelectrics and the response is obtained from the charge amplifier of measurement part. The response is sampled and converted to digital datas through AID converter. These digital datas are automatically saved in the external RAM of acquisition part. The computer takes the digital datas and calculates the electric displacement D, the electric field and the dielectric constant $\varepsilon$. We tested for PZT ceramic sample and could observed the D-E hysteresis lops and ${\varepsilon}_s$-E hysteresis loops with good forms.

  • PDF

파력발전용 병진 질량-스프링식 파력 변환장치의 동적설계 (Dynamic Design of a Mass-Spring Type Translational Wave Energy Converter)

  • 최영휴;이창조;홍대선
    • 한국생산제조학회지
    • /
    • 제21권1호
    • /
    • pp.182-189
    • /
    • 2012
  • This study suggests a dynamic design process for deciding properly design parameters of a mass-spring type Wave Energy Converter (WEC) to achieve sufficient energy conversion from wave to power generator. The WEC mechanism, in this research, consists of a rigid sprung body, a platform, suspension springs and dampers. The rigid sprung body is supported on the platform via springs and dampers and vibrates translationally in the heave direction under wave excitation. At last the resulting heave motion of the sprung body is transmitted to rotating motion of the electric generator by rack and pinion, and transmission gears. For the purpose of vibration analysis, the WEC mechanism has been simply modelled as a mass-spring-damper system under harmonic base excitation. Its maximum displacement transmissibility and steady state response can be determined by using elementary vibration theory if the harmonic ocean wave data were provided. With the vibration analysis results, the suggested dynamic design process of WEC can determine all the design parameters of the WEC mechanism, such as sprung body mass, suspension spring constant, and damping coefficient that can give sufficient relative displacement transmissibility and the associated inertia moment to drive the electric generator and transmission gears.

전력구 내 전자기파에 대한 작업 환경 측정 (The Measurement of Electromagnetic Wave in Power Cable Tunnel of Underground Utility Tunnel)

  • 강대곤;박재학
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Electromagnetic measurements of the power cable tunnel were conducted from August 10 to 20, 2018, in the ${\bigcirc}{\bigcirc}$ city underground utility tunnel. During this period, the average temperature was $31.89^{\circ}C$ and the humidity was 67.56% in power cable tunnel. As a result of the electromagnetic measurement, the highest electric field was 25.3 V/m and the magnetic flux density was $42.6{\mu}T$. The average electric field was 18.56 V/m and the magnetic flux density was $29.32{\mu}T$ in the power cable tunnel. As a result of comparison with the electric equipment technical standard, the electric field in the power cable tunnel was 0.5% of the electric equipment standard and 35.2% of the magnetic flux density. It's similar value that electric field is about robotic vacuum(15.53 V/m), and magnetic flux density is similar value about capsule- type coffee machine ($23.07{\mu}T$). The number of cable lines and the size of the electromagnetic waves were not proportional to each other through comparison of cable lines in the power cable tunnel. It was confirmed that 154 kV, rather than 22.9 kV, could have a greater influence on occupational.

Looseness Estimation of Bolts on Truss Structure with PZT Patches

  • Jiang, Zhongwei;Akeuchi, Yasutaka
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.86.6-86
    • /
    • 2002
  • This work presents a study on development of a practical and quantitative technique for assessment of the healthy state of a structure by piezoelectric impedance-based technique associated with longitudinal wave propagation measuring method. A truss structure embedded with piezoelectric patches is investigated for a fundamental study on estimation of the looseness of bolts in the joint. In order to evaluate the minute mechanical impedance change due to loosening bolt, a harmonic longitudinal elastic wave is applied to the structure by a pair of PZT patches and their electric impedance is measured simultaneously. According to the experimental results, the change of the electric impedance of P...

  • PDF

Terahertz Generation Based on Cascaded Difference Frequency Generation with Periodically-poled KTiOPO4

  • Li, Zhongyang;Wang, Silei;Wang, Mengtao;Wang, Weishu
    • Current Optics and Photonics
    • /
    • 제1권2호
    • /
    • pp.138-142
    • /
    • 2017
  • Terahertz (THz) generation by periodically-poled $KTiOPO_4$ (PPKTP) with a quasi-phase-matching scheme based on cascaded difference frequency generation (DFG) processes is theoretically analyzed. The cascaded Stokes interaction processes and the cascaded anti-Stokes interaction processes are investigated from coupled wave equations. THz intensities and quantum conversion efficiency are calculated. Compared with non-cascaded DFG processes, THz intensities from 10-order cascaded DFG processes are increased to 5.53. The quantum conversion efficiency of 479.4% in cascaded processes, which exceeds the Manley-Rowe limit, can be realized.

지중선로 누전점 탐지를 위한 반주기 변조된 대지 펄스 측정 (The measurement of the half period modulated pulse on earth for detection of a underground electric leakage point)

  • 김재현;전정채;유재근
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5123-5127
    • /
    • 2011
  • 증가 추세인 지중 전력설비의 사고 예방과 유지 보수를 위한 기술 연구 개발 요구가 증가하고 있다. 지중선로의 경우 누전 불량의 점유율이 높고 보수도 어려워 정확한 누전점 위치의 탐지가 중요하다. 교류 송신파를 누전점을 가지는 지중선로에 인가하여 발생시킨 교류 대지전위를 측정하여 누전점의 위치를 찾는 방법은 송신파 특정 극성반주기에 교류 대지전위를 동기화하여 비교 판단하여야 한다. 송신파의 특정 극성의 반주기와 동기화하는 기존 방법을 설명하고, 송신파 반주기 변조된 대지 전위 측정 방식을 제안하고 소개하였다. 실험을 통하여 제안한 방식이 구현 가능함을 확인하였다.

RF 스퍼터를 이용하여 미리 가열된 기판을 냉각하며 증착한 ZnO 박막의 c축 배향성 향상에 관한 연구 (Improvement of c-axis orientation of ZnO thin film prepared on pre-heated substrate with cooling during RF sputter deposition)

  • 박성현;이순범;신영화;이능헌;지승한;권상직
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.24-25
    • /
    • 2006
  • In this paper, ZnO thin films were prepared on p-Si(100) by RF magnetron sputtering. Before the depostion, the substrates were pre-heated to 500, 400, 300, $200^{\circ}C$ or not. During the deposition, the substrates were cooled down naturally or kept and then the films were investigated by XRD(X-ray diffraction) and SEM (scanning micro scope). It is showed the most outstanding result that the film was prepared on the substrate were cooled from $400^{\circ}C$. When the substrate was cooled from a certain temperature during deposition, it could be improve the c-axis orientation and useful for application of SAW(surface acoustic wave) filter and FBAR(film bulk acoustic wave resonator) device.

  • PDF

2D Computational Analysis of Overtopping Wave Energy Convertor

  • ;현범수
    • 한국해양공학회지
    • /
    • 제23권6호
    • /
    • pp.1-6
    • /
    • 2009
  • An Overtopping Wave Energy Convertor (OWEC) is an offshore wave energy convertor used for collecting overtopping waves and converting the water pressure head into electric power through hydro turbines installed in a vertical duct affixed to the sea bed. A numerical wave tank based on the commercial computational fluid dynamics code Fluent is established for the corresponding analysis. The Reynolds Averaged Navier-Stokes equation and two-phase VOF model are utilized to generate the 2D numerical linear propagating waves, which are validated by the overtopping experiment results. Calculations are made for several incident wave conditions and shape parameters for the overtopping device. Both the incident wave periods and heights have evident effects on the overtopping performance of the OWEC device. The computational analysis demonstrates that the present overtopping device is more compatible with longer incident wave periods.

선형발전기가 탑재된 파랑에너지 추출장치 설계 -II. 선형발전기 (Design of Wave Energy Extractor with a Linear Electric Generator -Part II. Linear Generator)

  • 조일형;최장영
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제17권3호
    • /
    • pp.174-181
    • /
    • 2014
  • 선형발전기가 연결된 부이의 수직운동에 대한 시간영역 해석을 수행하여 얻은 시계열 자료를 가지고 선형발전기를 설계하고 전기에너지 출력특성 및 효율에 대해 살펴보았다. 1차 변환장치로 원통형 부이를 선택하였고, 2차 변환장치로 양측식 할박(Halbach) 배열 영구자석 가동자와 철심형 슬롯리스(Slotless) 고정자로 구성된 선형발전기를 사용하였다. 시간영역에서 부이의 수직운동 속도와 파랑하중을 입력자료로 직선형 영구자석 발전기가 설계되었고, 설계된 발전기는 규칙파 조건에서 유한요소 해석법을 적용하여 발전특성해석을 수행함으로써, 그 타당성이 입증되었다. 또한 불규칙파 조건에서 합리적이고 빠른 해석을 위해, 등가회로법을 적용하여 발전특성 해석을 수행하였는데, 그 결과 역시 매우 타당함을 확인하였다.