• 제목/요약/키워드: electric tree

검색결과 143건 처리시간 0.035초

수력발전소 설비 신뢰성 분석을 위한 FMEA (FMEA for Facility Reliability Analysis of A Hydro-power Plant)

  • 권창섭;전태보
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.135-144
    • /
    • 2006
  • The significance of hydro-power plant is increasing in its public roles such as flood control and water supply as well as electric power production. Even if high level of reliability in facility operation is required, no specific reliability research has been made. This specifically stems from the lack of technology and research investments. The eventual goal of this study is to secure a methodology for reliability analysis of hydro-power plant so that an appropriate decision for operation and investment can be made. Specific effort was put to develop a reliability model for water supply system within hydro-power plant. For this study, we briefly examined the overview of the hydro-power plant including the electric power generation facility system. We then discussed the facility reliability analysis methodology for hydro-power plant. Based on rigorous examination of the water supply system and components roles, we drew major failure modes for each component and examined their effects.

  • PDF

$Al_2O_3$가 충전된 DGEBA/MDA/SN 계의 절연열화 특성 (Dielectric Breakdown Characteristics of $Al_2O_3$ Filled DGEBA/MDA/SN System)

  • 조영신;심미자;김상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.209-211
    • /
    • 1996
  • The dielectric breakdown characteristics of DGEBA/MDA/SN system filled with $Al_2O_3$ under AC high electric field were investigated. As the filler content increased, the dielectric breakdown strength increased, but decreased at higher filler content than 5 phr. The probability of defects such as air bubbles, peel between filler and epoxy resin insulator, etc. increase proportionally to filler contents. Fillers blockade the treeing growth and relax the electric field at the tip of electrical tree and the treeing propagation rate decreases so that the strength showed higher strength at lower filler content than 5 phr.

  • PDF

XLPE의 절연파괴특성에 미치는 휘발성 불순물의 영향 (Effects of Volatile Impurities on Dielectric Breakdown Characteristics of XLPE)

  • 조영신;심미자;김상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.301-304
    • /
    • 1997
  • Effects of volatile impurities on deterioration characteristics of XLPE were investigated. Block type plate with needle-plane electrode and artificial void filled with $N_2$gas or humidity was subjected under high electric field. The dyed region by oxidation reaction around the artificial void filled with humidity was detected before tee initiation. Electrical tree was started from the tip of void filled with $N_2$gas earlier than humidity.

  • PDF

Long-term and Short-term AC Treeing Breakdown of Epoxy/Micro-Silica/Nano-Silicate Composite in Needle-Plate Electrodes

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권5호
    • /
    • pp.252-255
    • /
    • 2012
  • In order to characterize insulation properties of epoxy/micro-silica/nano-silicate composite (EMNC), long-term and short-term AC treeing tests were carried out undr non-uniform electric field generated between needle-plate electrodes. In a long-term test, a 10 kV (60 Hz) electrical field was applied to the specimen positioned between the electrodes with a distance of 2.7 mm in an insulating oil bath at $30^{\circ}C$, and a typical branch type electrical tree was observed in the neat epoxy resin and breakdown took place at 1,042 min after applying the 10 kVelectrical field. Meanwhile, the spherical tree with the tree length of $237{\mu}m$ was seen in EMNC-65-0.3 at 52,380 min (36.4 day) and then the test was stopped because the tree propagation rate was too low. In the short-term test, an electrial field was applied to a 3.5 mm-thick specimen at an increasing voltage rate of 0.5 kV/s until breakdown in insulating oil bath at $30^{\circ}C$ and $130^{\circ}C$, and the data was estimated by Weibull statistical analysis. The electrical insulation breakdown strength for neat epoxy resin was 1,763 kV/mm at $30^{\circ}C$, while that for EMNC-65-0.3 was 2,604 kV/mm, which was a modified value of 47%. As was expected, the breakdown strength decreased at higher test temperatures.

GOSST를 이용한우편물 교환센터의 가중치 반영 최적 위치의 선정 (Weighted Optimal Location of Mail Distribution Center Using GOSST)

  • 김인범;김준모
    • 대한전자공학회논문지TC
    • /
    • 제47권11호
    • /
    • pp.7-13
    • /
    • 2010
  • 우편물 배송에 있어서 신속함과 비용의 최소화를 위하여 각 구간별 운송거리와 더불어 우편 운송차량 수와 같은 가중치를 고려하여 우편물의 총 이동 거리를 최소화 할 수 있는 최적의 교환센터 선정이 필요하다. 본 논문은 구간별 운송 차량수와 운송 거리를 고려하여, 국내 주요 도시에 위치한 우편 집중국을 연결하는 최적 위치의 교환센터를 GOSST 이론을 이용하여 찾는 방법을 제안한다. 이 방법으로 교환센터의 위치를 선정할 경우, 현재의 대전을 교환센터로 하는 방법은 물론, 운송차량 수와 같은 가중치를 고려하지 않은 스타이너 트리 방법에 비해 전체 우편물의 총 이동거리를 줄일 수 있다. 제안 방법은 신속한 배송과 비용의 최소화는 물론 환경 보호 측면에서도 바람직하다할 수 있다. 제안된 방법은 실험에서 스타이너 트리를 이용한 방법에 비해 2.52%, 현재의 방법에 비해 6.66%의 우편물의 총 이동 거리를 절감시킬 수 있었다. 제안된 방법은 우편물 배송뿐 아니라, 다양한 전압 및 가중치를 고려해야하는 송전 시스템 라우팅, 배전선로망 구성, 전력 중계소의 위치 선정 등에도 활용가능하다.

과학적 방법을 적용한 화재조사와 결함수 분석을 이용한 정온전선의 발화원인 추론 (Fire Cause Reasoning of Self-regulating Heating Cable by a Fire Investigation Applying the Scientific Method and Fault Tree Analysis)

  • 김두현;이흥수
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.73-81
    • /
    • 2016
  • 정온전선은 평형 도체 사이에 반도전성 폴리머를 연속 압출 방식으로 충전시킨 후 양 도체 사이에 전기를 흐르게 함으로써 고분자에 의한 전열을 이용한 전기 발열체이다. 정온전선은 가격이 저렴하고 시공이 편리하기 때문에 겨울철 수배관의 동파방지용 열선으로 주로 사용되고 있다. 하지만 이러한 유용함에도 불구하고 구조적인 문제로 인하여 두 평형 도체의 절연이 파괴되는 경우에는 화재로 이어질 수도 있는 위험성이 존재하고 있다. 본 논문은 정온전선에 의한 화재현장을 조사하여 원인을 도출하는 방식으로 직접적인 원인을 추론하고자 하였으며, 결함수 분석을 통해 근본적인 문제를 파악해 보고자 하였다. 실제 냉동창고 화재현장을 조사하여 정온전선에 의한 화재원인을 추론한 결과 전선 말단 절연처리 결함에 의한 절연파괴인 것으로 판단되었다. 향후 이 결과는 안전활동 및 유사 화재원인조사 시에도 활용될 수 있을 것이다

열쾌적성에 대한 가로수 수직적 구조의 영향 분석 (The Effects of Street Tree's Vertical Structures on Thermal Comfort)

  • 이수빈;최혜영;조현길;윤영조;길승호
    • 한국환경복원기술학회지
    • /
    • 제24권4호
    • /
    • pp.15-29
    • /
    • 2021
  • Urban green spaces offer a variety of benefits to living things and humans. However, existing green spaces have been reduced and fragmented due to urbanization, and there is a limit to creating new large green spaces in densely developed cities. Street trees have fewer restrictions on land use, which can be a measure to secure green areas in cities. In Korea, excessive pruning is being done on some street trees for reasons such as blocking of building signboards, contact with electric wires, and restrictions on sidewalk widths. Therefore, it is necessary to quantitatively understand the relationship between the benefits provided by street trees and their structures to come up with an efficient and systematic planning and management plan for urban street trees. In this study, we quantitatively analyzed the relationship between the thermal comfort improvement by the shades of street trees and the vertical structure, planting environment, and types of street trees. To calculate the thermal comfort felt by human body, we calculated UTCI (Universal Thermal Climate Index) of each street tree. For the vertical structure of street trees, we used Terrestrial LiDAR and the point clouds of street tree's crown was sliced vertically at 1m intervals. We conducted a multiple regression analysis on the thermal comfort improvement using the variables we obtained from fields. As a result, in the case of a street tree's vertical structure, the lager the volume of tree's crown located 3-4m (β=0.298, p<.05) and 6-7m (β=0.568, p<.001) above clear length, the better the cooling effect. In addition, the thermal comfort improvement was assessed to decrease as the DBH increased (β=-0.435, p<.001). In general, the crown diameter and DBH are positively correlated, with a cooling effect occurring as crown diameter increases. In this study, the opposite result was obtained due to the small number of trees measured, so additional research is needed by increasing the number of tree samples. In the case of the planting environment, the effect of improving thermal comfort was higher in the shaded area of trees planted to the south (β=-0.541, p<.001). Since unsystematic management of street trees can deteriorate the function of them, quantitative evaluations of the vertical structure of street trees are required, which can provide specific measures for planning and management of urban street trees with thermal comfort effect.

건설현장 임시전력 배선의 가설직무에 대한 인간신뢰성 평가 (Human Reliability Assessment for a Installation Task of Temporary Power Cables in Construction Fields)

  • 김두현;이종호;김상철
    • 한국안전학회지
    • /
    • 제20권2호
    • /
    • pp.61-66
    • /
    • 2005
  • This paper presents an human reliability assessment(HRA) for a installation task of the temporary power cable in construction fields. HRA is evolved to ensure that the workers could reliably perform critical tasks such as a process of the temporary power cable. Human errors are extremely commonplace, with almost everyone committing at least some errors every day. The considerable parts of electric shock accidents in the construction field are caused by a series of human errors. Therefore it is required to analyze the human errors contained in the task causing electric shock event, the event tree analysis(ETA) is adopted in this paper, and particularly human reliability was estimated for a installation task of the temporary power cables. It was assumed that the error probabilities of the human actions may be obtained using the technique for human error rate prediction(THERP). The results show that the predominant task on reliability in the cable installation tasks is check-out tasks and the probability causing electric shock by human errors was calculated as $1.0\times10^{-9}$.

오염된 누전차단기 절연재료의 트래킹 특성에 관한 연구 (A study on the Tracking Characteristics of Contaminated Insulating Materials of RCD)

  • 이춘하;옥경재;김시국;지승욱
    • 한국화재소방학회논문지
    • /
    • 제22권5호
    • /
    • pp.67-71
    • /
    • 2008
  • 본 논문은 국내에서 사용되고 있는 누전차단기 외함 절연재료의 오염에 의한 트래킹 특성을 연구하였다. IEC (International Electrotechnical Commission) 60589의 방법으로 만들어진 0.1 wt% NaCl 용액을 이용하여 KSC IEC 60112의 고체절연재료의 내트래킹 및 비교트래킹지수 측정 방법을 응용하여 실험을 하였다. 실험에 사용된 시료는 3개 제조사의 누전차단기를 사용하였으며, 누전차단기의 절연재료가 오염되었을 때 탄화도전로 발생시간 및 트래킹 발생형태를 분석하였다. 연구결과, 제조사별로 탄화도전로의 발생 시간 및 트래킹 발생형태가 상이하게 나타났다. 오염된 차단기의 절연재료의 트래킹 발생 시간이 정상시료보다 빠르게 나타났다.

천연기념물 노거수 활력도 측정에 관한 연구 -경상도 천연기념물 느티나무를 중심으로- (A Study of Vitality Measurements of the Natural Monuments - Focused Natural Monuments Zelkova in Kyongsangdo -)

  • 하태주;방광자
    • 한국환경복원기술학회지
    • /
    • 제8권1호
    • /
    • pp.100-107
    • /
    • 2005
  • As a result of this study, vitality of natural monuments (large trees) looks relatively good but they require continuous management. Also, the management for condition recovery and condition maintenance, and minimum measures are needed at least to avoid natural calamity. Major points induced are as follows : The first, although most of natural monument large trees showed favorable growth environment, most of them are aged and have dense twigs with requirement for weed trimming to remove complicated and unnecessary branches. In addition, as most of large trees grow alone in a large space with potential natural calamity, thus, minimum measures are required at least. Secondly, change in electric resistance in surveyed large trees was relatively favorable, however, large trees with soil covering showed high electric resistance and were found to have low vitality. As shown, this study was conducted to find out the measurement techniques of natural monuments, Basic foundation is suggested through the measurement of electric resistance, and the vitality of natural monuments; more accurate investigation will be remained for further discussion.