• 제목/요약/키워드: electric tree

검색결과 143건 처리시간 0.028초

초고압 XLPE 케이블 금속 차폐층 고찰 (A study or Metallic sheath for Extra-high voltage XLPE cable)

  • 최창수;이갑중;정무영;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.

  • PDF

FTA를 이용한 교류전철변전소의 신뢰도 분석 (Reliability Analysis of AC Railway Substation by using FTA)

  • 구본희;차준민;김형철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.248-254
    • /
    • 2008
  • Electric railway system consists of traction power system, rolling stock, track, and overhead line system. A railway substation transforms the electric power transmitted from a electric power company and supply it to the railway power system for the operation of traction system.. It is very important to prevent a possible accident and keep the security of electric power system. This paper proposes a reliability analysis of AC railway substation by using Fault Tree Analysis(FTA). Failure rates of each equipment of railway substation are used to evaluate the reliability of railway substation. The analyzed results can be used to improve the system reliability. FTA is performed by the commercialized program of Relex(Ver. 7.7).

  • PDF

Electric Heat Tracing을 위한 Zigbee 기반 통합 감시제어 시스템의 개발 및 검증 (Development and Verification of Zigbee-Based Monitoring and Control System for Electric Heat Tracing)

  • 박성우;박순응
    • 한국전자통신학회논문지
    • /
    • 제10권12호
    • /
    • pp.1395-1402
    • /
    • 2015
  • Electric heat tracing 시스템은 플랜트 내 각종 배관의 온도를 관리하는 시스템이다. 본 논문에서는 electric heat tracing 시스템을 통합적으로 감시하고 제어하기 위한 TESCON(: TEmperature Sensing and CONtrol) 시스템을 제안한다. TESCON 시스템에서 디바이스간의 정보 교환은 Zigbee 네트워크 기반의 무선 방식으로 이루어진다. TESCON 시스템의 성능 분석을 위해 컴퓨터 시뮬레이션을 수행하였다. 테스트베드를 통해서도 비슷한 결과를 얻음으로써 TESCON 시스템의 유효성을 입증하였다. 또한, 계층적 트리 토폴로지를 기반으로 하는 네트워크 분할, 채널 재사용, 프레임 집약 기법 등을 적용한 시스템 확장 방안도 제시하였다.

침전극 곡률반경에 따른 LLDPE/EVA의 교류트리 특성 (A Study on the AC Treeing Characteristics with Tip Radius of Needle Electrode in LLDPE/EVA)

  • 이재필;이충호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.476-480
    • /
    • 2003
  • Polyethylene used as insulating material of power cable is nonpolar and low dielectric loss polymer. But it has defects of tree generation and accumulation of space charge by an applied voltage resulting in the decreased life and performance. To solve these problems, mixed films with LLDPE and EVA that is similar to LLDPE at physical properties in case of low VA contents were made and tested due to the blend ratios of 80:20, 70:30, 60:40 and 50:50[wt%] respectively. We investigated AC electrical treeing characteristics to acquire the best mixture ratio and effect of the tip radius of needle electrode to develop excellent treeproof materials. The degree of crystallity calculated with XRD pattern is higher for pure LLDPE, 50:50 and 70:30. For DSC analysis, it is confirmed that the melting points of mixed specimens are lower than that of pure LLDPE and higher than pure EVA's. The shape of tree propagation showed that pure EVA was electrical tree shape of the branch type, pure LLDPE and blended specimens was able to confirm tree shape of the bush type. As the tip radius go up in the blend ratio 70:30 specimen, the tree inception voltage rise. Probably the reason is the relaxation of electric field in the specimen with bigger tip ratio. As the 6 specimens were applied AC 5[KV],7.5[KV],10[KV] respectively, tree growth length is far shorter in the specimen with blend ratio 70:30, 50:50 than in pure EVA and pure LLDPE specimen. Conclusively, it is confirmed that specimens of which blend ratio are 70:30 and 50:50 are good in electrical tree retardant characteristics, especially, 70:30 has lower dielectric loss than 50:50 and its mixture ratio is the best.

  • PDF

FTA를 이용한 수변전설비의 최소절단집합 도출 (Minimal Cut Set of Electric Power Installations using Fault Tree Analysis)

  • 박영호;김두현;김성철
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.41-46
    • /
    • 2017
  • In this paper, from making an electrical fire which is thought to be the most damaging among potential dangers as a top event, minimal cut sets (MCS) about it were analyzed. For this, components of a power substation were classified into 15 items. Failure rates and modes were extracted based on Korea Electrical Safety Corporation, IEEE Gold Book, and RAC. To analyze the top event (an electrical fire), main events were assorted into "safety devices for overcurrent" and "ampere meter of detecter". Failure of components was divided into failure of VCB, COS, and MCCB. A fault tree was composed of 3 AND gate, 5 OR gates and 17 basic events. Overlapped events among the basic events are things which occur from relevant components. They were attached to the tree by distinguishing identifiers. In case of FT, two minimal cut sets of "IO_METER", "MF_METER", "DO_MCCB" and "IO_METER", "MF_METER", "DO_VCB" take 46% of electrical fires. Therefore, about basic events which are included in the top two minimum cut sets, strict control is necessary.

ANFIS 분류기법을 이용한 부분방전원의 분류 (PD classification by using ANFIS method)

  • 박성희;윤재훈;김병철;임기조;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.467-467
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is $7^*5^*7mm^3$. Distance between needle and plane is 2 mm. Voltages applied to acceleration test are ranged 12 to 15 kV. And distribution characteristic of degraded stage is studied too. By PD detecting and data processing, discharge data was acquired from PD detecting system (Biddle instrument). The system presents statistical distribution of phase resolved. Moreover, the processing time of electrical tree is recorded to know the speed of degradation according to voltage. Finally, it's used PD classification by ANFIS method.

  • PDF

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권3호
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.

Nutrient Leaching from Leaf Litter of Cropland Agroforest Tree Species of Bangladesh

  • Hasanuzzaman, Md.;Hossain, Mahmood
    • Journal of Forest and Environmental Science
    • /
    • 제30권2호
    • /
    • pp.208-217
    • /
    • 2014
  • Leaf litter is the main and quick source of organic matter and nutrient to the soil compared to other parts of litter. This study focused on the nutrients (N, P and K) leaching from leaf litter of Melia azadirachta, Azadirachta indica, Eucalyptus camaldulensis, Swietenia macrophylla, Mangifera indica, Zizyphus jujuba, Litchi chinensis, Albizia saman, Artocarpus heterophyllus, Acacia auriculiformis, Dalbergia sissoo and Khaya anthotheca as the common cropland agroforest tree species of Bangladesh. About (9 to 35) % of initial mass was lost, while Electric Conductivity (EC) and TDS (Total Dissolved Solid) of leaching water increased to (573 to 3,247) ${\mu}S/cm$ and (401 to 2,307) mg/l respectively after 192 hours of leaching process. Mass loss (%) of leaf litter, EC and TDS of leaching water showed significant (ANOVA, p<0.05) curvilinear relationship with leaching time. Initial concentration of NH4, PO4 and K in leaching water was found to increase significantly (p<0.05) up to 48/72 hours and then remained almost constant at later stages (48/72 to 192 hours). Mass loss of leaves; EC, TDS, $NH_4$, $PO_4$ and K in leaching water was varied also significantly (ANOVA, p<0.05) among the studied tree species. All the tree species showed similar pattern of nutrients (K>N>P) release during the leaching process. The highest $NH_4$ (4,097 ppm) and potassium (8,904 ppm) concentration was found for M. azadirachta while the highest $PO_4$ (1,331 ppm) concentration was found for E. camaldulensis in the leaching water. Among the studied tree species, M. azadirachta, A. indica, D. sissoo, E. camaldulensis and Z. jujuba was selected as the best tree species with respect to nutrient leaching.

기계적 스트레스가 XLPE에서의 전기트리 개시특성에 미치는 영향 (The Effects of Mechanical Stress on the Initiation Characteristics of Electrical Tree in XLPE)

  • 신두성;최수걸;전승익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.241-244
    • /
    • 2001
  • 절연체의 수명과 직접적인 관련이 있는 전기트리의 개시특성을 연구하는데 있어서, 전기트리의 개시시간이 매우 길기 때문에 실험적으로 절연재료의 수명을 구하는데 어려움이 있다. 따라서. 본 논문에서는 Weibull 해석을 이용하여, 일반적으로 사용되는 가속시험법에 의하여 얻어진 전기트리 개시전계를 사용하여 일정전압 인가시에 전기트리 개시시간을 추정하는 방법을 이론적으로 고찰하여 실험에 적용하였다. 또한 기계적 스트레스에 의한 전기트리 개시특성을 평가하기 위하여 기계적 스트레스를 모의한 XLPE 시료에 대하여 이러한 기계적 스트레스가 전기트리 개시전계 및 개시시간 특성에 미치는 영향을 평가하였다. 기계적 스트레스가 전기트리 개시전계 뿐만 아니라 개시시간을 현저하게 감소시켰으며, XLPE의 장기적인 신뢰성을 보증하기 위해서는 이러한 기계적 스트레스를 완화시키는 것이 매우 중요하다.

  • PDF

지중배전선로의 다회로차단기 운영방안 연구 (The Study of Multi-Circuit Breaker Coordination in the Underground Distribution Line)

  • 조남훈;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.143-151
    • /
    • 2000
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the distribution line, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. On underground distribution line, the serving of cables by earth-moving equipment is a prevalent cause of faults and the most cable faults quickly develop into bolted current. we introduce th multi-circuit breaker coordination methods in the Underground Distribution Line.

  • PDF