• Title/Summary/Keyword: electric shock hazard

Search Result 28, Processing Time 0.02 seconds

A Study on the Theoretical Analysis of Human Body Approximation to Special High Voltage Eletric Lines (특별고압 전선로에 대한 인체접근한계의 이론적연구)

  • 김상렬;김찬오;이재인
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.44-50
    • /
    • 1990
  • This study is conducted to examine the theoretical background of characteristics for electric shock encountered in special high-voltage electric lines among the accidents of electric shock, and to calculate applied current to human body and field strength over the head by means of numerical anaysis through FEM(Finite Element Method), and to make clear the hazard level to the human body, and to establish the approach limit distance of human body to the electric lines, which could be applied to the safety standard while working in the vicinity of special high-voltage electric lines.

  • PDF

A Study on the Characteristic of Electrical Construction Work for Prevention of Electric Shock Accident (감전재해 예방을 위한 전기공사업의 특성에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.29-34
    • /
    • 2014
  • The live line working is inherently dangerous as the workers have to work under the risk of electrical shock and most of works are carried out at height. The live line working need the some specific techniques and higher level safety measures such as a risk assessment to carry out works safely, but the electrical construction companies performed live-line working are usually small-sized companies. They have less capacity to have own safety management system. This study intended to conduct an in-depth analysis on the cause of electric shock accidents to provide basic data for policy proposing taking into considering the past eleven years for a long-term plan. And the aim of this study is to propose the policy about the equipment performance standards and/or worker's safety standards to revise the standards for preventing electric shock accidents, moreover, co-relation of the electrical work order form and on safety workings, especially electrical construction company/work.

A study on the hazard of electric shock for 220V domestic receptacles (220V 가정용 콘센트에 대한 감전위험성 연구)

  • 한기붕;정세중;이대종
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.671-674
    • /
    • 2000
  • A children's electric shock accidents have broken out because children can easily insert sharp things in 220V receptacle holes. As the test result of pushing force, children's pushing force was about 2-4kg and the pushing force of sharp things was less than 2kg. Therefore, it is reason for electric shock that children's pushing force is large than pushing force of sharp things. We have measured insulation resistance for the receptacles of five companies during 50 weeks in humid condition. As these results, Insulation resistance for the receptacles of J. Co. had rapidly decreased with lapse of time. As the result for investigating the surface of receptacle by SEM and EDX, Al, Fe and Br, which weren't discovered at original form, were produced. Therefore, the receptacles of J. Co. should be the improved in the quality of insulating material because insulation resistance can be decreased in humid environment

  • PDF

Analysis of Electric Shock Accidents and Check Results in Domestic and Foreign low-Voltage Handhole (국내.외 저압지중함 감전사고사례 및 점검결과의 분석)

  • Kim, Chong-Min;Han, Woon-Ki;Bang, Sun-Bae;Kim, Han-Sang;Shim, Keon-Bo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.124-131
    • /
    • 2008
  • Recently underground electrical power distribution is increased because people attach importance to aesthetics of the downtown areas. Lew-voltage handhole of underground distribution line for joint and branch point is mainly installed at the sidewalk. So, pedestrian can get a electric shock if fault is occurred in the low-voltage handhole. Furthermore the street was flooded by recently an unusual change in the weather. Fault is occurred in the low-voltage handhole that may create a shock hazard for the human body because a person's body resistance lower due to effect of water. This paper analyses causes of electric shock accidents and check results at the low-voltage handhole. At a result of analysis, the causes of electric shock accidents in domestic and foreign low-voltage handhole are same but environmental conditions of low-voltage handhole are different In the future, the analytical data can be applied to prevent the electric shock at the low-voltage handhole, and can be used to basic data for the improving installment of low-voltage handhole.

DC Leakage Current Properties Analysis of the LED Lamps of Road and Landscape Lighting (LED 가로등 및 경관조명의 직류 누전 특성 분석)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.885-891
    • /
    • 2011
  • In this paper, we studied dc leakage current properties analysis of LED lamps of road and landscape lighting when leakage current appeared in dc power line. Generally, converter of LED lighting is divides to insulated type and non-insulated type according to components. When electric leakage happened in AC power line, earth leakage breaker(ELB) senses leakage current and interrupts electric circuit. In dc power source, We need experimental verification about dc electric leakage for electricity safety. In normal wiring conditions and in the water, in case of using insulated type of converter, dc leakage current did not occur. However, in case of using non-insulated type of converter, dc leakage current occurred and passed through into the ground. We found that there is a hazard of electric shock by dc leakage current. We expect that the results of these studies would be helpful for electrical safety of LED lamps for road and landscape lighting.

A Study on the statistiscal analysis and the Electrical Shock hazard for electrical power facilities of 22.9kV substation (22.9kV 수.변전설비의 감전사고 발생현황 및 감전위험성 연구)

  • Han, Ki-Boong;Lee, Dae-Jong;Han, Woon-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1813-1815
    • /
    • 2002
  • As the statistical data, the electrical shock accidents by electrical power facilities of 22.9kV substation is about 100 per years which shows very high occupation rate of 11.3%. There is many hazard factors in this place using high voltage because electrical accident can be occurred in near live part as well as contact. Regarding electrical shock accident in 22.9kV substation as there are many cases that have not been exposed industrial disaster, it is very hard to know exact causes of such accidents in many cases, and therefore it is difficult to set up effective preventive measures. Therefore in this paper, it is intended to prepare the basic data to establish more effective preventive measures of electric shock accidents in 22.9kV substation through understanding the real conditions based on investigation and analysis in various types.

  • PDF

A Method for Evaluating Electric Shock Hazards Based on Human Body Current (인체전류를 기반으로 하는 감전의 위험성 평가방법)

  • Lee, Bok-Hee;Yoo, Yang-Woo;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.

The Survey of Fire Hazard of Fan in Manufacturing Industries (제조 사업장의 환풍기 화재위험성 조사)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.21-29
    • /
    • 2013
  • The short circuit and overload is presented by main cause of electrical fire. However, 85% of the fan directly connected the outlet box without switch in total 110 fans as a research in manufacturing industries. In installation direction of vertical type fans which was placed on the horizontal surface, only 39 vertical type fans were placed on vertical surface and 71 fans were placed on the horizontal type. The installation direction of the fans warns of the risk of the fire hazard due to the motor stall to the user manual of the maker. However, it is the representative nonconformity example of construction which the people or builder disregards. In addition, the condition of ground connection with the earth leakage prevention was investigated in grounding of 5 fans, non-grounding of 105 fans. The double insulation structure is generally used for small fan and it can't connect ground wire as electric plug of non-grounding type. However, industrial iron fan needs ground wire for electric leakage and to protect against electric shock.

A Survey on Regulations of Safety Helmet for Preventing Fall Hazard (추락위험 방지용 보호구로서 안전모 규정에 관한 고찰)

  • Sang Woo, Shim;Yong Su, Sim;Jong Bin, Lee;Seong Rok, Chang
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.96-101
    • /
    • 2022
  • The Occupational Safety and Health Act holds that industrial safety helmets can be used as protective equipment to prevent the risk of injury in fall accidents. To better understand the importance given to PPE for the head, we analyzed the relevant regulations and guidelines in developed countries and reviewed the guidelines on testing safety helmets. The PPE regulations in Korea were notably different from those in other countries. First, except in Korea and Japan, safety helmets were used for protection against falling objects, flying objects, impact, or electric shock. However, the regulations did not recognize safety helmets as a PPE against fall hazards. Second, the impact energy applied on the helmet was within the range 50-100 J, and the helmet could protect only the upper part of the head against hazards such as the impact of falling objects, flying objects, etc. Third, in Korean regulations, the term "fall" was used in relation to the parts where the safety helmet was specified as a fall hazard PPE, unlike in other countries. We propose that the term "fall" should be revised to "shock" in Korean regulations for the safety helmet.