• Title/Summary/Keyword: electric shock accident

Search Result 51, Processing Time 0.04 seconds

A Study on the statistiscal analysis and the Electrical Shock hazard for electrical power facilities of 22.9kV substation (22.9kV 수.변전설비의 감전사고 발생현황 및 감전위험성 연구)

  • Han, Ki-Boong;Lee, Dae-Jong;Han, Woon-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1813-1815
    • /
    • 2002
  • As the statistical data, the electrical shock accidents by electrical power facilities of 22.9kV substation is about 100 per years which shows very high occupation rate of 11.3%. There is many hazard factors in this place using high voltage because electrical accident can be occurred in near live part as well as contact. Regarding electrical shock accident in 22.9kV substation as there are many cases that have not been exposed industrial disaster, it is very hard to know exact causes of such accidents in many cases, and therefore it is difficult to set up effective preventive measures. Therefore in this paper, it is intended to prepare the basic data to establish more effective preventive measures of electric shock accidents in 22.9kV substation through understanding the real conditions based on investigation and analysis in various types.

  • PDF

The analysis of checking results and electric shock accident happens at domestic and foreign low-voltage handhole (국내외 저압지중함의 감전사고 및 점검결과 분석)

  • Kim, Han-Sang;Bang, Sun-Bae;Kim, Chong-Min;Han, Woon-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.91-94
    • /
    • 2007
  • The increased use of underground power distribution as opposed to overhead lines contributes to the aesthetics of the downtown areas. But there is an inherent risk of accidental electrocution should there be damage to the insulation of the cable because of heavy rain. Should a pedestrian make contact with this cable indirectly, via a man hole cover, electrocution could result. In this paper, we analyse electrical shock accident and checking results in this low-voltage handhole.

  • PDF

An Analysis on the Accident Influence Factor and Severity of Construction General Workers (건설 보통인부의 안전재해 영향요인 및 재해강도 분석)

  • Shin, Won-Sang;Son, Chang-Baek
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.69-76
    • /
    • 2018
  • General workers who assist various technicians in different fields with their work across the whole construction sites without having a particular skill are at risk of the highest accident rate and their accident form becomes varied. Accordingly, this study was conducted to identify the relationship between form of safety accident and influence factor in general workers and analyze accident severity by influence factor. The followings are the results from this study. First, as a result of analyzing major form of accident and influence factors in general workers with network analysis methodology, nine forms of accident and seventeen influence factors were drawn. Second, it was found that in accident severity among general workers, collapsing, among various forms of accident, appeared the highest, followed by fall, electric shock, fire, hit by an object, bumped against, trip, scission getting cut chopped in order. Third, main points of special, concentrated, and permanent management were presented in order to reduce the safety accident in general workers effectively.

The status of parents' education and their perception for young children's safety (유아안전을 위한 부모교육의 경험 및 부모의 인식도)

  • Hong, Myoung-Hee;Chong, Young-Sook;Jang, Hye-Ja
    • Korean Journal of Human Ecology
    • /
    • v.13 no.5
    • /
    • pp.741-749
    • /
    • 2004
  • The purpose of this study was parents' perception on young children's safety life, safety accident, and safety education and provided basic data of administrating parent education for young children's safety. Subjects of this study were 620 parents (310 fathers and 310 mothers) of young children attending at four public kindergartens and two day care centers located in C city and D county. The results of the study were as follows: First, regarding parents' perception on young children's safety life, parents thought that their perception and attitude would mostly affect young children' safety life. Second, with regard to parents' perception on safety accident, half of parents experienced such safety accident as accident during play, traffic accident, accident in dangerous places, accident from dangerous matters, accident in sport activities, fire, and electric shock. Third, most parents looked upon safety education as very important one, and fathers were more satisfied with the safety education administered by kindergartens. Fourth, with regard to parents' perception on parent education for young children's safety, most parents thought that parent education for safety would be necessary. They ranked traffic and play accidents as the most important contents of safety education.

  • PDF

The Tools Development for Electric Shock Accident Prevention at Electric Construction Work (전기공사 작업시 감전사고 방지용 공구류 개발)

  • Lee, H.K.;Kim, H.J.;Baek, S.H.;Won, S.H.;Lee, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.43-45
    • /
    • 2005
  • Electric accidents, like getting electrified, sometimes happen to people working on electricity. A highly probable reason why these electric accidents happen is that workers are used to skip confirming disconnection of electricity when they work. It is mostly because they have little understanding of electricity. To overcome this, various applications such as 'electric detecting stick' are invented to check existence of electricity on working environment. But, they have not been popular due to inconvenience of carrying. So, we made a new instrument. It is a kind of nipper on which electric detecter is installed. Detecting existence of electricity is less burdensome via this tool we made.

  • PDF

The Tools Development for Electric Shock Accident Prevention at Electric Construction Work (전기공사 작업시 감전사고 방지용 공구류 개발)

  • Lee, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.158-160
    • /
    • 2005
  • Electric accidents, like getting electrified, sometimes happen to people working on electricity. A highly probable reason why these electric accidents happen is that workers are used to skip confirming disconnection of electricity when they work. It is mostly because they have little understanding of electricity. To overcome this, various applications such as I electric detecting stick' are invented to check existence of electricity on working environment. But, they have not been popular due to inconvenience of carrying. So, we made a new instrument. It is a kind of nipper on which electric detecter is installed. Detecting existence of electricity is less burdensome via this tool we made.

  • PDF

Performance Evaluation of Protection against Electric Shocks for TT and TN Systems (TT, TN접지계통의 감전보호 성능평가)

  • Lee, Bok-Hee;Choi, Young-Chul;Yoo, Jae-Duk;Shin, Hee-Kyung;Yang, Soon-Man;Kim, Tae-Gi;Lee, Zu-Cheul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.315-318
    • /
    • 2009
  • Electric shock is the accident caused by the current through a person or animal's body. That is characterized by the physiological effects. In this paper, we evaluate performance of protection against electric shocks for TT and TN grounding systems which are used by a low voltage consumer nowadays. The performance of protection against electric shocks for TT grounding system is very excellent in equipotential area of the third class grounding, but the performance is poor outside the equipotential area. The performance of protection against electric shocks for TN grounding system is excellent because the potential difference is less than 50V. Accordingly, the performance of protection for TN grounding system is good as compared with that for TT grounding System.

  • PDF

Investigation on the Health and Safety Hazards of Construction Workers

  • Kal, Won-Mo;Park, Jong-Tae;Son, Ki-Sang
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.43-46
    • /
    • 2005
  • The construction workers might be at the risk of many occupational injuries and illnesses. To protect workers from various hazards, industrial health and hygiene systems were specified for the construction workers by law. It is important to know the actual health and safety(H&S) conditions by tasks and the characteristics of injuries and illnesses of construction workers. This study was designed to investigate the actual conditions of construction workers exposed to various harmful substances and work elements including evaluation of health status of each worker and general H&S system. Questionnaire was sent to 600 construction workers nationwide and totally 367 people responded to it having 61.67% of response rate. The common construction hazards were dust(29.6%), noise(19.3%), repetitive motions(12.0%), handling excessive heavy materials(11.2%) in order. The repetitive motions and handling heavy materials related to muscle disorders accounted for 23.2%. The accident and injury types were in order of overexertion, falling, overturning, dropping or flying, electric shock, collision, etc.

A Study on the Identification of Electrical Materials by a Fire (화재로 인한 전기재료 감식에 관한 연구)

  • 박남신;홍진웅;조경순
    • Fire Science and Engineering
    • /
    • v.6 no.1
    • /
    • pp.90-98
    • /
    • 1992
  • Over the last 100 years since the introduction of electricity, the nation has faced ever increasing demand for electricity as consequence of the rapid economic growth. The expanded consumption ratio for electricity naturally increased the possibility for electricity related accident mainly iii the form of electrically ignited fire and human injuries from electric shock. Under such circumstances, the presented study sets a focus on analysing the causes of the electrically related fire accidents happened in the nation over the last 10 years(in the 80's) to provide a scientific basis for identifying the cause of electric fires. Identification of the cause of fire ignited electrically may be approached either by studying accident related electrical properties or by investigating power instruments at the place of the accient. In the present paper, the former approach is taken especially on investigating the consequences of over current induced by short circuiting of high power instruments which is reported as the primary cause electricity related fire accidents. In order to provide reliability of the identification method, microscopic photograph's are taken for the cross sections of the electrical materials(fuse, wire, plug socket and plug) after being exposed to over current and heated by external means respectively. The results are consequently compared and analysed.

  • PDF

On-site Survey of the Street Lighting Facilities (가로등의 전기설비 현장실태조사)

  • Kim, Han-Sang;Bae, Suk-Myong;Kim, Chong-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.426-431
    • /
    • 2006
  • The case where a drain cannot flow backwards, a sewer institution can be unmanageable in this, and a mad is under water momentarily by local heavy nin by the climate phenomenon in spite of not being a lowlands belt has occurred well more than recently. By the flooded mea since it is in the state which has some human bodies at hand, when a short circuit occurs in street lighting pole which is the electric institution thing of a road, the danger of an electric shock accident becomes higher. In this paper, it was going to show improvement plan for grasping the brittle factor of street lighting pole electricity facilities through the on-site survey of street lighting pole electricity facilities, and improving this.