• 제목/요약/키워드: electric resistivity

검색결과 443건 처리시간 0.031초

전해액 온도에 의한 구리 박막의 표면형상과 물성 변화 (Property and Surface Morphology of Copper Foil on the Various Temperature of Electrolyte)

  • 우태규;이만형;박은광;배태성;이민호;박일송;정광희;설경원
    • 대한금속재료학회지
    • /
    • 제47권4호
    • /
    • pp.256-260
    • /
    • 2009
  • This study examined the effects of plated temperature on the surface morphology and property of an electrodeposited copper foil. The morphology, crystal structure and electric characteristics of the electrodeposited copper foil were examined by scanning electron microscopy, X-ray diffraction, and a four-point probe, respectively. The surface roughness, crystal growth orientation and resistivity could be controlled using various temperature of electrolyte. Large particles were observed on the surface of the copper layer electroplated onto the $30^{\circ}C$. However, a uniform surface, lower resistivity and high flexibility were obtained when a $50^{\circ}C$ electrolyte was used.

암반 비탈면의 인장균열 위치 선정에 관한 사례 연구 (Case Study on Location of Possible Tension Crack in Rock Slope)

  • 전병곤;김지성;강기천
    • 한국지반공학회논문집
    • /
    • 제37권3호
    • /
    • pp.5-17
    • /
    • 2021
  • 본 연구는 도로건설공사 중 발생한 암반 비탈면의 인장균열 발생원인 및 대책 방안을 소개하고자 한다. 확장 가능한 인장균열 범위를 조사하기 위하여 전기비저항 탐사를 수행하여 암반의 연약대 분포 여부를 조사한 결과, 인장균열이 발생한 부체도로 하단에 저비저항대가 나타나며 굴착 비탈면 상단 부근에 저비저항대가 분포하는 것으로 확인되었다. 따라서 발생 가능한 인장균열 위치를 굴착 비탈면 상단으로 결정하여 보강 설계를 수행하였고, 보강방안으로 앵커와 억지말뚝 2열이 제안되었고 비탈면 안정해석을 통하여 보강 이후 허용안전율을 만족하는 것으로 나타났다.

지하 동굴 탐지에 효율적인 지구물리탐사기법 연구: 제주도 만장굴을 대상으로 (Effective Geophysical Methods in Detecting Subsurface Caves: On the Case of Manjang Cave, Cheju Island)

  • 권병두;이희순;이규호;임형래;오석훈
    • 한국지구과학회지
    • /
    • 제21권4호
    • /
    • pp.408-422
    • /
    • 2000
  • 지하의 공동탐사에 효과적인 지구물리탐사 기법에 대해서 연구하기 위하여 제주도 만장굴을 대상으로 복합적인 지구물리탐사를 수행하였다. 이번에 사용한 방법은 탐사장비나 야외작업이 비교적 경제적이면서도 지하 공동에 의한 반응을 잘 보여줄 것으로 기대되는 중력, 자력, 전기 비저항, GPR(지하레이더) 탐사 등이다. 현지의 탐사여건을 고려하여 7개의 측선을 선정하고, 각 측선별로 몇 종류의 탐사를 복합적으로 실시하였다. 자력탐사의 경우는 2차원 격자형탐사도 함께 수행하였다. 각 탐사자료상에는 탐사법에 따른 여러 특징들이 잘 나타나고 있어, 그 효용성을 비교 분석할 수 있었다. 이번에 사용한 방법 중 동굴 탐사에 가장 효과적인 탐사법은 전기비저항탐사로 나타났으며, 쌍극자-쌍극자 배열법은 2차원적인 고비저항대로 나타나는 동굴의 존재를 잘 보여준다. 중력, 자력 탐사의 결과는 화산암 지역에서 나타나는 다양한 잡음의 영향으로 동굴의 위치나 규모를 해석해 내기가 쉽지 않지만, 전기비저항탐사 자료에서 인지되는 동굴의 위치와 규모가 적절한지를 검증하는 데에 효과적으로 이용될 수 있었다. 한편, 2차원 격자형 자력탐사 자료는 동굴의 경향성을 잘 보여주므로, 정밀 탐사측선을 결정하는데 유용하다. GPR탐사 자료에는 천부에 존재하는 미세한 틈새들과 소규모 공동들에 의한 반응이 강하게 나타나 상대적으로 심부에 위치하는 주동굴의 존재를 확인하기는 힘들었다. 이번 연구의 결과는 제한 된 수의 탐사법만을 적용하였기 때문에 어떤 결정적인 결론을 내리기는 어렵지만, 지하 동굴의 경우는 복합적인 탐사를 수행하고 그 자료들을 상호보완적으로 사용함으로써 해석결과의 신뢰도를 높일 수 있는 것으로 나타났다.

  • PDF

이상대 판정기법을 활용한 지하매설물 탐사 (Exploration of underground utilities using method predicting an anomaly)

  • 류희환;김경열;이강렬;이대수;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.205-214
    • /
    • 2015
  • 급격한 도시화 및 산업화는 전력구를 비롯한 공동구의 수요를 증가시키고 있다. 하지만 기존 지하매설물, 특히 전력구에 대한 불충분한 정보와 지하매설물의 무분별한 건설로 인해 최근 도심지 내 새로운 지하매설물을 건설하는 것이 매우 어렵다. 뿐만 아니라, 전력구를 비롯한 지하매설물이 건설된 위치와 방향에 대한 부족한 정보는 신규 지하매설물의 계획노선을 설정하는데 많은 문제를 야기시키고 있다. 이러한 문제를 해결하기 위해서 본 연구에서는 기존의 전기비저항 탐사방법과는 다른 이론적 방법으로 해결하고자 하였다. 전력구를 비롯한 지하매설물이 건설된 지반에서 가우스 법칙과 라플라스식을 이용하여 전기장 해석이 수행하였다. 전력구의 방향, 전력구의 위치, 전력구의 전기전도도 등의 함수로 표현된 전기비저항 이론식은 전기장해석을 통해서 획득하였다. 이론식을 검증하기 위해서 현장실험이 수행되었으며 현장실험 결과, 지반 내 지하매설물의 위치와 방향을 오차범위 내에서 예측하였다.

이온교환막을 이용한 이온의 분리특성에 관한 연구 - I. 전바나듐계 레독스-흐름 전지의 격막용 이온 교환막의 특성 - (The Study on the Separation Characteristics of ion with ion Exchange Membrane - I.The Characteristics of ion Exchange Membrane with the Separator of All-Vanadium Redox Flow Battery -)

  • 강안수
    • 공업화학
    • /
    • 제4권2호
    • /
    • pp.393-402
    • /
    • 1993
  • 레독스-흐름 2차전지는 발전소의 잉여 전력, 태양전지 및 전기자동차 등 응용 분야가 넓은 유망한 에너지 저장 방법의 하나이다. 활성물질로소 바나듐-황산 수용액을 이용하는 전바나듐 레독스-흐름 전지에서 효율적인 이온 선택 성막의 개발은 아직도 문제점으로 남아 있다. 전바나듐 레독스-흐름 전지용 격막으로서 기초막에 UV를 조사하면서 30분간 chlorosulfonation 시킨 비대칭 양이온 교환막(M-30)이 운반율 0.94 막저항 $0.5{\Omega}{\cdot}cm^2$로 가장 좋았다. 기초막은 pololefin막(HIPORE 1200)에 $10{\mu}m$두께의 저밀도 폴리에틸렌 막을 접착시켜 제조되었다. 실제 바나듐-황산 수용액에서의 막저항도 $3.79{\Omega}{\cdot}cm^2$로 Nafion 117막과 비슷하였고, 셀저항율도 $6.6{\Omega}{\cdot}cm^2$로 Nafion 117막보다 낮았다. 막의 전기화학적 물성치와 가격 등을 고려할 때 전바나듐 레독스-흐름 전지의 격막으로서 M-30막이 Nafion 117막과 Asahi초자의 CMV막보다 우수하였다.

  • PDF

Bi-2212/Cu-Ni 튜브로 제작한 초전도 한류소자의 단락사고시험 결과 (Fabrication and Fault Test Results of Bi-2212/Cu-Ni Tubes for Superconducting Fault Current Limiting Elements)

  • 오성용;임성우;유승덕;김혜림;현옥배
    • Progress in Superconductivity
    • /
    • 제10권1호
    • /
    • pp.45-49
    • /
    • 2008
  • For the development of superconducting fault current limiters (SFCLs), fault current limiting elements were fabricated out of Bi-2212 bulk tubes and tested. The SFCL elements consisted of tube shaped Bi-2212 bulks and metal shunts for the stabilizers. Firstly, the Bi-2212 bulk tubes were processed based on a design of monofilar coils in order to acquire large resistance and high voltage rating. 300 mm-long Bi-2212 tubes were designed to have the current path of 410 cm in length with 24 turns and 41 mm in diameter. The processed monofilar coil, as designed, had 300 A $I_c$ at 77 K. The fabricated superconducting monofilar coils were affixed to Cu-Ni alloy as that of stabilizers. The Cu-Ni alloys were processed to have the same shape of the superconducting monofilar coils. The Cu-Ni coil had resistivity of 32 ${\mu}{\Omega}$-cm at 77 K and 37 ${\mu}{\Omega}$-cm at 300 K. The metal shunts were attached to the outside of the Bi-2212 monofilar coil by a soldering technique. After the terminals made of copper were attached to both ends of the superconductor-metal shunt composite, the gap between the turns and the surface of the elements was filled with an epoxy and a dense mesh made of FRP in order to enhance the mechanical strength. The completed SFCL elements went through fault tests, and we confirmed that the voltage rating of 143 $V_{rms}$ (E =0.35 $V_{rms}$/cm) could be accomplished.

  • PDF

$Al_2O_3+Y_2O_3를 첨가한 {\beta}-SiC-TiB_2$ 복합체의 특성 (Properties of the $\beta-SiC-TiB_2$ Composites with $Al_2O_3+Y_2O_3$ additives)

  • 임승혁;신용덕;주진영;윤세원;송준태
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권7호
    • /
    • pp.394-399
    • /
    • 2000
  • The mechanical and electrical properties of pressed and annealed $\beta-SiC-TiB_2$ electroconductive ceramic composites were investigated as a function of the liquid forming additives of $Al_2O_3+Y_2O_3$. Phase analysis of composites by XRD revealed $\alpha$-SiC(6H), TiB2, and (Al5Y3O12). Reaction between Al2O3 and $Y_2O_3$ formed YAG but the relative density decreased with increasing $Al_2O_3+Y_2O_3$ contents. The Flexural strength showed the value of 458.9 MPa for composites added with 4 wt% $Al_2O_3+Y_2O_3$ additives at room temperatures. Owing to crack deflection and crack bridging, the fracture toughness showed 6.2, 6.0 and 6.6 MPa.m1/2 for composites added with 4, 8 and 12 wt% Al2O3+Y2O3 additives respectively at room temperature. The resistance temperature coefficient showed the value of $3.6\times10^{-3},\; 2.9\times10^{-3}\; and\; 3.0\times10^{-3} /^{\circ}C$$^{\circ}C$ for composite added with 4, 8 and 12 wt% $Al_2O_3+Y_2O_3$additives respectively at room temperature. The electrical resistivity of the composites was all positive temperature coefficient resistance(PTCR) in the temperature range of $25^{\circ}C\; to\; 700^{\circ}$.

  • PDF

필댐의 안정성 해석 연구 (1) (A STUDY ON THE SAFETY ANALYSIS OF ROCK FILL DAM (1))

  • 손호웅;이대근
    • 지구물리
    • /
    • 제6권3호
    • /
    • pp.165-177
    • /
    • 2003
  • 필댐의 안정성 해석에 있어서 누수와 내부침식은 매우 중요한 평가의 한 부분이다 연구대상 지역의 필댐은 내부침식으로 추정되는 댐 상부의 공동발생 및 과대 누수량으로 문제가 발생하여, CGS(compaction grouting system)으로 보강공사를 수행하였으며, 본 보강방법은 주입재료 및 주입압력이 중요한 변수로 작용을 한다. 본 연구에서는 CGS 보강이 필댐의 안정성에 미치는 영향을 CGS보강 전후에 지구물리탐사를 수행하여 해석하였다. 본 조사에 적용된 방법에는 전기비저항탐사, 탄성파 굴절법탐사, GPR탐사, HFMT탐사 등이 적용되었다. 조사결과 CGS 보강으로 댐의 전제척인 거동에 많은 영향을 준 것으로 나타났으며, 주입압력이 과대하여 댐 중심코아에 많은 변위가 발생된 것을 확인할 수 있었다.

  • PDF

반사층을 이용한 FBAR(SMR)의 제조 (Fabrication of FBAR (SMR) using Reflector)

  • 이재빈;곽상현;김형준;박희대;김영식
    • 한국재료학회지
    • /
    • 제9권12호
    • /
    • pp.1263-1269
    • /
    • 1999
  • 본 실험에서는 반사층(reflector)을 이용한 FBAR (Film Bulk Acoustic Resonator) 즉, SMR (Solidly Mounted Resonator) 제조에 필요한 재료들의 최적 증착 조건을 설정하여, 이를 바탕으로 제조한 SMR의 특성을 보여주었다. SMR은 상하부 전극층, 압전 박막층, 반사층, 기판으로 구성된다. 상하부 전극으로 알루미늄(Al) 금속 박막을 사용하였고 압전 박막층으로 산화아연(ZnO) 박막을 사용하였다. 실리콘(Si) 기판과 하부 전극 사이에 위치하는 반사층은 5층의 이산화규소 ($Si_2$)와 텅스텐(W) 박막으로 구성되었다. 상하부 전극은 dc 스퍼터링 방법으로 증착아였으며 반사층과 압전 박막층은 rf 스퍼터링 방법으로 증착하였다. 최적 증착 조건에서 증착된 산화아연 (ZnO) 박막은 rocking curve에서 표준편차가 $2.17^{\circ}$의 우수한 c축 우선배향성, 비저항은 $10^4\;{\Omega}cm$이상, 막 표면 거칠기(rms roughness)는 10.6${\AA}$의 특성을 나타내었다. 최적 증착 조건에서 증착된 텅스텐(W)과 이산화규소($Si_2$) 박막의 특성은 박막 거칠기 (rms roughness)가 각각 16 ${\AA}$, 33 ${\AA}$을 나타내었다. 또한 증착된 알루미늄 금속 박막의 비저항은 $5.1{\times}10^{-6}\;{\Omega}cm$이었다. 반도체 기본 공정을 이용하여 면적 $250{\times}250\;{\mu}m^2$의 SMR 소자를 만들고, 네트웍 분석기로 SMR 소자의 공진 특성을 분석하였다. 공진특성은 1.244 GHz에서 직렬공진, 1.251 GHz에서 병렬공진을 나타내었다. SMR 소자의 공진특성에서 공진기의 Q값은 1200이었다.

  • PDF

지하매설물의 기하학적 특성에 따른 전기저항 변화에 대한 수치 해석 연구 (Numerical Analysis of Electrical Resistance Variation according to Geometry of Underground Structure)

  • 김태영;류희환;정성훈
    • 대한토목학회논문집
    • /
    • 제44권1호
    • /
    • pp.49-62
    • /
    • 2024
  • 급격한 도시화로 인한 지하의 무분별한 개발은 기존 지하매설물의 점검과 교체 그리고 새로운 지하시설물 설치에 지연을 일으키고 있다. 최근에는 체계화된 시스템을 도입하여 지하시설물을 관리하고 있지만, 실제 시공은 현장 여건에 따라서 설계 도면과 다르게 진행되기 때문에 기존 지하매설물의 부정확한 위치 정보로 사고가 끊임없이 발생하고 있다. 한편, 전기비저항 탐사는 전극을 지반에 관입시켜 전극 간 전위차로 지반의 전기저항을 측정하는 방식이며, 비파괴 물리탐사 기법으로서 널리 이용되고 있다. 그리고 다수의 전극 쌍을 이용하여 복잡한 지하 구조를 영상화하고, 딥러닝 알고리즘을 활용한 데이터 해석 기술들이 비약적으로 발전하였지만, 아직 지하매설물의 기하학적 조건에 따른 전기저항 변화를 정량적으로 평가한 기초적인 연구로서는 진행된 바가 없다. 본 연구에서는 전극과 지하매설물의 기하학적 매개 변수 해석을 통해서 전기저항 변화를 평가하였다. 먼저, 이론식과 수치 해석의 전기저항값 차이가 작게 나타난 정량화된 메쉬를 적용하여 3차원 전기저항 수치 해석 모듈을 개발하고, 매설물의 깊이, 크기, 그리고 전극과 매설물 간 이격거리에 따른 매개 변수 해석을 통해서 정상 직류 상태에서 전기저항 변화를 정량적으로 비교하였다. 전기저항은 매설물이 얕은 깊이에 위치하고, 크기가 크고, 전극과의 이격거리가 가까울수록 높게 측정되었다. 추가적으로 전극과 지하매설물 주변에 형성된 전위 및 전류밀도 분포를 분석하여 터미널 전극 주변에서 측정된 전기저항을 고찰하였다.