• Title/Summary/Keyword: electric railway system

Search Result 773, Processing Time 0.027 seconds

Modelling Voltage Variation at DC Railway Traction Substation using Recursive Least Square Estimation (순환최소자승법을 이용한 직류도시철도 변전소의 가선전압변동 모델링)

  • Bae, Chang-Han
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.534-539
    • /
    • 2015
  • The DC overhead line voltage of an electric railway substation swings depending on the accelerating and regenerative-braking energy of trains, and it deteriorates the energy quality of the electric facility in the DC railway substation and restricts the powering and braking performance of subway trains. Recently, an energy storage system or a regenerative inverter has been introduced into railway traction substations to diminish both the variance of the overhead line voltage and the peak power consumption. In this study, the variance of the overhead line voltage in a DC railway substation is modelled by RC parallel circuits in each feeder, and the RC parameters are estimated using the recursive least mean square (RLMS) scheme. The forgetting factor values for the RLMS are selected using simulated annealing optimization, and the modelling scheme of the overhead line voltage variation is evaluated through raw data measured in a downtown railway substation.

Developing electric railway load pattern inspection program (전철 변전소 전력부하패턴 점검 프로그램 개발)

  • Jeon, Yong-Joo;Lee, Gi-Chun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.893-898
    • /
    • 2007
  • At present, one of the big characteristics in electric power market in korea is unique seller but in the near future competitions are expected in the market. so additional service for the electric power are expected. Also with development of IT technology, remote inspection for power usage are possible so as consumption pattern analysis. KORAIL is one of the biggest consumer in electric power market so it is necessary to investigate power consumption pattern. This paper presents electric load consumption pattern for representative substation like urban subway, high-speed train, industrial line and simulation program for electric power rate definition program based on billing system database. Base on the substation annual power usage DB data, the characteristic of the substation power consumption are investigated and effective electrical billing system are compared each other. Through this program it is verified that we can save more then several hundred million won for a year.

  • PDF

A Case Study of Degradation Characteristics for Rod-Insulator on Catenary System in Electric Railway (전기철도 전차선로 지지애자의 염해지역 열화특성 사례 연구)

  • Jung, Hosung;Park, Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.263-266
    • /
    • 2019
  • In the Airport Railroad, the Yeongjong Bridge has a length of 4,420 m and connects Yeongjong Island with the mainland of Incheon City. The bridge is a two-level structure, consisting of a six-lane road at the upper level and a combination of a road and railroad at the lower level. The environmental conditions for the electric railway come mainly from the salt injury area and a heavy industry zone, and the maintenance cycles are determined differently depending on these conditions. This study analyzed the deterioration characteristics of long rod insulators produced with a movable ceramic bracket and polymer materials in the Yeongjong Bridge section of the Airport Railway operating in the salt injury area according to the material characteristics. Comparison of the corona measurements when the insulators were cleaned at the same time showed that the polymer insulator had a higher insulation performance than the ceramic insulator.

Analysis of the Power Supply System of a Maglev Train (자기부상열차의 급전시스템 검토)

  • Lee, Hyung-Woo;Kwon, Sam-Young;Park, Hyun-June
    • Proceedings of the KSR Conference
    • /
    • 2006.11a
    • /
    • pp.209-218
    • /
    • 2006
  • This paper presents the comparison and analysis of the power supply system of a Maglev train and conventional electric railway. Even though all Maglev trains have batteries on their vehicles, electric power supply from the ground side is necessary for levitation, propulsion, on-board electrical equipment, battery recharging, and so on. At low speeds up to $100{\sim}150(km/h)$, the Maglev train, generally, uses a mechanical contact, a current collector as same as conventional electric railway. However, at high speeds, the Maglev train can no longer obtain power from the ground side by using a mechanical contact. Therefore, high speed Maglev trains use their own way to deliver the power to the vehicle from the ground. In this paper, the power supply systems of the german, japanese, and korean low- and high-speed Maglev trains have been reviewed.

  • PDF

The Effect of Corrosion on the Fatigue Life of Catenary Wire (부식에 의한 가선재 수명특성에 관한 연구)

  • 김용기;장세기;이덕희;정병철
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.139.1-146
    • /
    • 2001
  • Contact lines are necessary to supply electric locomotives with electric power. As most railways are gradually electrified with modernized electric cars, the demand for catenary wires and their facilities are also increased. Catenary wires made by metallic materials are generally used in the open air. They are exposed to the marine area with air-borne salt or severely polluted industrial area with much corrosive emission gases depending on the railway locations. In urban area, acid rain may cause a degradation of catenary wire system. Corrosion of catenary wires can make their actual lifetime shorter than that originally designed. Thus, the messenger wires, a kind of catenary wire system, were investigated with respect to corrosion, which include new and the used one collected at the field. They are also vibrated with some amplitude everytime the train passes through the railway. The frequent cyclic load on the wire any result in a fatigue damage, Surface damage by corrosion can make fatigue crack initiate with ease. In the present study, the fatigue life of the used wire was measured 40 to 50% shorter than that of new one in average.

  • PDF

Manufacture and Performance Evaluation of Insulating Transformer for surge protection under Electric Railway Environments (전기철도환경하에서의 서지방호용 절연변압기 제작 및 성능평가)

  • Lee, K.W.;Kim, M.Y.;Ohn, J.G.;Park, D.W.;Park, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.176-177
    • /
    • 2006
  • The main aim of the paper is the study of the surge voltages in electric railway signal security system. Hence these studies will provide means of introducing a suitable protective device insulating transformer. This influences the surge voltage interrupting capacity using surge arresters and bypass capacitors. This circuit can be used for investigating surge phenomenon in electric railway signal security system. In this paper a insulating transformer has been introduced for the reduction of surge voltages in the above circuit model and performance evaluation.

  • PDF

Study for electromagnetic compatibility of electric train system (전기철도의 전자기적합성에 관한 고찰)

  • Kim Min-Cheol;Lee Jang-Mu;Han Moon-Soeb
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.883-888
    • /
    • 2005
  • In modern system, electromagnetic environment are going worse with advancing electric and electronic technology, and this electromagnetic environment affect modern electric train system at the point of the safety problem. Therefore, each distributed system that is consisting electric train system have to prove there own electromagnetic compatibility through the field test. These distributed system can be considered as power supply system, signal & communication system and train system. In this study, essential field tests for electromagnetic compatibility of train system based on IEC national standard are suggested.

  • PDF

Comparison and Analysis of Return Current Measurement Values on High Speed Line (고속선 귀선전류 측정값 비교 및 분석)

  • Kim, Yong-Kyu;Kim, Ju-Yeop;Oh, Seh-Chan;Baek, Jong-Hyun;Yoon, Yong-Ki;Kwak, Woo-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.877-884
    • /
    • 2017
  • A method of common earth, which is proposed by French Railway(SNCF) and is applied to high speed railway, minimizes the effect of the traction return current from tracks so that trackside electric devices can be protected and operation and maintenance staffs are kept out from injury in an electric railway environment. According to it, all the new domestic electric railway lines are replaced from existing individual earth method to the common earth method. In this paper, we analyze the correlation between common earth method and traction return current to prove whether the common earth has surely contributed to minimize the effect of the traction return current. The analysis was done based on the measurement of the traction return current at the domestic high speed railway line.

Screening Effects of Double-track Electric Railway and Shielded Cables on Communication-Line Inductive Interference (전기철도 복선화 및 차폐 케이블 적용에 따른 통신선 유도장해 차폐 효과)

  • Seol, Il-Hwan;Choi, Kyu-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5148-5155
    • /
    • 2013
  • The induced voltage on the telecommunication cable generated by nearby electric railway system may bring about telecommunication errors and safety accidents. In order to reduce the induced voltage and to achieve communication reliability, the effect of the shield cables and the recent double-track railway systems on the inductive interference should be investigated. This paper analyzes the parameters which seriously influence the induced voltage on the telecommunication cables which run parallel with a AT-fed electric railway line, and provides a simulation-based approach to estimate the amount of the induced voltage. Simulation results indicate that the induced noise voltage generated by a double-track railway decreases by 18 % compared to that generated by a single-track railway, showing the screening effect by nearby track. The induced noise voltages on the 50%-shielded cable and 15%-shielded cable decrease to 1/8 and 1/15 of the induced voltage on the non-shielded cable, respectively. A meaningful shield effect is achieved and the induced voltage is minimized by the double-track railway and the shielded cable.

Railway Switching Point Heating System Using the Photovoltaic-Wind Power Hybrid (태양광-풍력 하이브리드를 이용한 철도 선로전환기 융설 장치 구현)

  • Kim, Dae-Nyeon;Park, Han-Eol;Kim, Deok-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.136.1-136.1
    • /
    • 2011
  • This paper proposes the method to implement the railroad switching point heating system using the hybrid of the photovoltaic and wind power. The goal of the implementation of the railroad switching point heating system is to prevent freezing of the snow in the winter. The heating system of railway used to supply electricity through photovoltaic and wind power to prevent freezing. Hot wires of the railroad switching point heating system are used about 2kW of electric energy at the day. The electric energy of 2kW used the length of the hot wires about 3m. As the ON and/or OFF mode considering the tracks temperature and the ambient temperature, so the way the use of power-saving effect. In addition, the system can be used the railroad switching point heating system in winter and railway signal and street lights around the track in summer. In experiment, we acquired the power data according to time at the day of photovoltaic and wind power. We confirmed the temperature rise using the heating cable for 3m of $85^{\circ}C$, 30W/m. The temperature rise of the heating cable changes the temperature of $5^{\circ}C$ after 10 minutes and $11^{\circ}C$ after 10 minutes. We have confirmed the possibility of the railroad switching point heating system using the hybrid of the photovoltaic and wind power.