• 제목/요약/키워드: electric power transmission network

검색결과 131건 처리시간 0.024초

송전요금 결정을 위한 전력조류 추적법의 도입 및 효용성 검증 (Introduction of Power Flow Tracing Method for Determination of Power Transmission Network Charge and Verification of Its Effectiveness)

  • 노경수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권2호
    • /
    • pp.53-58
    • /
    • 2002
  • This paper describes methodologies to charge for power transmission network use. These methodologies are normally divided into two categories such as marginal cost method and embedded cost allocation method. This paper, first, discusses the possible problems that can occur when the marginal cost method is applied to pricing the transmission services. Next, the paper proposes a method to apply the electricity tracing method to the transmission network charge. The result of the electricity tracing method is then used in MW-mile method to charge individual loads for the use of transmission network. Effectiveness of the algorithm is verified by computer simulations and it is estimated that the results can be used to compute the cost of electric power transmission under deregulated environment in electric power industries.

지진 재해에 대한 전력 송전 네트워크 시스템의 신뢰성 평가 모형 (A Model for Seismic Reliability Assessment of Electric Power Transmission Network System)

  • 고현무;김영호;박원석
    • 한국지진공학회논문집
    • /
    • 제7권2호
    • /
    • pp.93-102
    • /
    • 2003
  • 지진 하중을 받는 전체 네트워크 시스템 및 네트워크 구성 절점에 대한 신뢰성 지수를 구할 수 있는 지진 재해 신뢰성 평가 방법을 전력 송전 네트워크 시스템을 대상으로 개발하였다. 전력 송전 시스템에 대하여 절점과 링크로 구성된 네트워크 모형을 개발하였으며, 절점인 변전소의 지진 취약도 곡선은 변전소 구성 기기의 개별 취약도 곡선으로부터 구하였다. 입력 지진 모형으로서 점 지진원 모형을 사용하였고, doubly truncated Gutenberg-Richter 관계식과 감쇠공식을 적용하였다. 몬테 카를로 시뮬레이션을 적용하여 전력 송전 네트워크 시스템의 신뢰성을 평가한 결과 한국의 전력망에 대한 지진 재해의 효과는 무시할 수 있는 수준은 아닌것으로 평가되었다.

전자기파 부분방전 신호의 권선 투과 특성 (Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding)

  • 주형준;한기선;윤진열
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

미얀마 500kV 송전망 기본설계 (Basic Design for the 500kV Transmission System In Myanmar)

  • 백승도;김종화;최영성;한성민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.40-41
    • /
    • 2006
  • KEPCO conducted the project called the "Feasibility Study & Basic Designs for the 500kV Transmission System in Myanmar" as its second overseas project following the "Development Study on the Power System Network Analysis in Myanmar" as it first project. This paper deals with the design processes and results of 423 kilometers of the 500kV single circuit transmission lines and three substations. The main contents of the basic design include insulation design, transmission line design and substation design.

  • PDF

미래 전력 계통의 불확실성을 고려한 송전혼잡비용 분석 (An Analysis of Congestion Cost for Electric Power Transmission in Consideration of Uncertainty of Future Electric Power System)

  • 박성민;김성수
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.131-137
    • /
    • 2014
  • It is expected that there will be delay of scheduled transmission network reinforcement and huge investment of renewable energy resources in Korea. As transmission capacity expansion delayed, supplying power to Seoul metropolitan area will not be increased as scheduled. In addition, uncertain renewable energy out of Seoul metropolitan area can cause transmission congestion in the future power system. These two combining effects will make the difference in locational marginal prices(LMP) and congestion costs increase. In that sense, this paper will analyze how much the congestion costs for Korea power system are incurred in the future power system. Most of previous approaches to analyze the congestion costs for electric power system are based on the optimal power flow model which cannot deal with hourly variation of power system. However, this study attempted to perform the analysis using market simulation model(M-Core) which has the capability of analyzing the hourly power generation cost and power transmission capacity, and market prices by region. As a result, we can estimate the congestion costs of future power system considering the uncertainty of renewable energy and transmission capacity.

미얀마 장기 계통계획 수립 결과 및 전망 (Master Plan for Long-term Transmission System in Myanmar)

  • 허연;김종화;한경남;최영성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.9-11
    • /
    • 2005
  • kEPCO is now conducting a project called the "Feasibility Study & Basic Designs for the 500kV Transmission System in Myanmar" as its second overseas project following the "Development Study on the rover System Network Analysis in Myanmar" performed from 2001 to 2002. As a part of this project, this paper deals with the analysis process and results of the demand forecasts, master plan for transmission system expansion, and the major factors for the new 500kV transmission facilities.

  • PDF

차폐선을 이용한 미얀마 500kV 변전소 차폐보호범위 계산 (Calculation of shielding range using shield wires in Myanmar 500kV Substation)

  • 박흥석;김태영;조영선;박찬섭;주세환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.189-191
    • /
    • 2005
  • In the past, dramatic economical development of Korea could be achieved by well-organized 154kV power system network. Electric power Is a key Industry for the nation and industrial development. Nowadays we operates 345kV Power system with based transmission network and also we are operating 765kV power system to supply to the capital region. Currently developing countries in Southeast Asia are requiring the electric power technology to Korea so that they can acquire the source of the development-power system network. Therefore, it Is important to design transmission line and substation with appropriate methods. In this paper, a calculation and calculating process of shielding range using shield wires in Myanmar 500kV substation are reviewed according to the Myanmar 500kV power system project performed by the overseas projects section of the Korea Electric Power Corporation.

  • PDF

A PMSM Driven Electric Scooter System with a V-Belt Continuously Variable Transmission Using a Novel Hybrid Modified Recurrent Legendre Neural Network Control

  • Lin, Chih-Hong
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.1008-1027
    • /
    • 2014
  • An electric scooter with a V-belt continuously variable transmission (CVT) driven by a permanent magnet synchronous motor (PMSM) has a lot of nonlinear and time-varying characteristics, and accurate dynamic models are difficult to establish for linear controller designs. A PMSM servo-drive electric scooter controlled by a novel hybrid modified recurrent Legendre neural network (NN) control system is proposed to solve difficulties of linear controllers under the occurrence of nonlinear load disturbances and parameters variations. Firstly, the system structure of a V-belt CVT driven electric scooter using a PMSM servo drive is established. Secondly, the novel hybrid modified recurrent Legendre NN control system, which consists of an inspector control, a modified recurrent Legendre NN control with an adaptation law, and a recouped control with an estimation law, is proposed to improve its performance. Moreover, the on-line parameter tuning method of the modified recurrent Legendre NN is derived according to the Lyapunov stability theorem and the gradient descent method. Furthermore, two optimal learning rates for the modified recurrent Legendre NN are derived to speed up the parameter convergence. Finally, comparative studies are carried out to show the effectiveness of the proposed control scheme through experimental results.

디지털 TRS를 이용한 배전자동화통신망 구축 방안 (Design of the digital TRS network for for the Distribution Automation System)

  • 김태경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.420_421
    • /
    • 2009
  • The digital TRS(Trunked Radio System) is an excellent alternative for the transmission medium for the DAS(Distribution Automation System). KEPCO(Korea Electric Power Corporation) made the power IT network with digital TRS system. The main function of the radio network is transmitting and receiving information for the DAS. KEPCO's digital TRS is based on TETRA standard. The digital TRS supports data communication for the electric power control and monitoring systems in various ways.

  • PDF

변전소의 다중상태를 고려한 송전시스템의 내진 신뢰성 평가 (Seismic Reliability Evaluation of Electric Power Transmission Systems Considering the Multi-state of Substations)

  • 고현무;박영준;박원석;조호현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.66-73
    • /
    • 2003
  • The technique for the seismic reliability evaluation of the electric power network is presented. In the previous study, the state of the substations was represented by the bi-state which is classified as failure or survival. However, the hi-state model can result in oversimplified analysis, because substations are worked by the parallel operating system. In this paper, Considering the characteristics of the parallel operating system, the damage of the substation is expressed by the multi-state for the more realistic seismic reliability evaluation. Using Monte-Carlo simulation method, the seismic reliability for Korean 345㎸ electric power network is evaluated. Analysis results show that reliability levels of the network by the multi-state analysis is higher than that by the hi-state analysis and the electric power network in southeastern area of the Korean Peninsular may be vulnerable to earthquakes.

  • PDF