• Title/Summary/Keyword: electric potential method

검색결과 413건 처리시간 0.025초

DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법 (Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop)

  • 이기옥;유병규;유권종;최주엽;최익
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

접속형 가변 전자계 자극에 대한 경락반응특성 (Response Properties of Meridians for focused variable electromagnetic stimulus)

  • 이균정;조동국;김수병;권선민;신태민;이경중;이용흠
    • 한국정보통신학회논문지
    • /
    • 제13권7호
    • /
    • pp.1399-1410
    • /
    • 2009
  • 통증을 치료하기 위한 방법으로 약물요법, 신경차단법, 외과적 수술 등이 있으며, 대체물리요법으로 침구치료, 초음파, 전기 치료, 자기장 치료 등이 응용되고 있다. 이중 전기치료 요법이 많이 이용되고 있으나, 피부나 피하조직의 임피던스에 큰 영향을 받으며, 주로 경피자극이 주된 방법으로 효과가 매우 확률론적이다. 본 연구에서는 집속형 자기장을 이용하여 경혈이나 치료점에 대한 국소 부위를 비침습적으로 자극 할 수 있는 새로운 시스템을 개발하였다. 수기자극과 유사한 자극을 유도할 수 있는 새로운 자기장 침 전극(자기장 자극의 효율성을 고려하여 새로운 형태)을 설계하였다. 개발된 시스템의 임상적 유효성 및 신뢰성을 평가하기 위하여 수기자극과 자기장 자극에 대한 경락전위변화를 측정하여 비교하였다. 실험 결과 자기장 자극 시 수기자극을 할 때 나타나는 충전 방전 형태의 전위변화와 유사한 경락전위변화가 측정되었으며, 자극방식, 세기, 빈도를 조절함에 따라 다양한 반응특성이 나타남을 확인하였다. 또한, 전자기장 자극에 의해 경락전위변화를 유도할 수 있어 이를 이용한 새로운 경혈자극 및 통증치료기로써의 가능성을 확인하였다.

GPR 기반 콘크리트 슬래브 시공 두께 검측 기법 개발 (Development of Thickness Measurement Method From Concrete Slab Using Ground Penetrating Radar)

  • 이태민;강민주;최민서;정선응;최하진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권3호
    • /
    • pp.39-47
    • /
    • 2022
  • 국내의 공동주택 보급률 증가에 따라 층간소음으로 인한 문제가 증가하고 있다. 이를 예방하기 위하여 바닥 충격음 차단 구조에 대한 수요가 높아지고 있으며 해당 구조에 대한 성능 인증이 이뤄지고 있지만 소음 차단 성능이 현장에서는 재현되지 않는다는 문제점이 있다. 해당 구조가 제 성능을 발휘하기 위해서는 일정 두께 이상의 마감 모르타르 타설이 필요하며, 해당 구조의 시공 적정성 판정을 위하여 GPR을 이용한 두께 측정 실험을 진행하였다. 본 연구에서 개발한 두께 측정 알고리즘은 측정된 데이터를 기반으로 상대유전율을 설정할 수 있어 정확한 두께 값을 측정할 수 있다. 네 종류의 바닥 충격음 차단 인증 구조에서 GPR 두께 측정 실험을 진행하였으며, GPR 데이터와 천공 측정 데이터 간 평균 오차는 1.95mm로 나타났다. 또한 마감재 유무가 측정값에 미치는 영향을 조사하기 위하여 총 3가지 종류의 마감재를 배치하고 실험을 진행으며, 평균 오차는 1.70mm로 나타났다. 추가적으로 장비의 샘플링 오차, 개발 알고리즘 변수, 천공 오차등을 종합적으로 고려하였을 때, GPR 계측 및 제안 알고리즘은 매우 높은 정확도로 슬래브 마감 모르타르의 두께 측정에 적용할 수 있음을 확인하였다.

이산화망간 전기증착 리그닌 기반 탄소나노섬유 매트를 이용한 슈퍼캐퍼시터용 전극소재의 전기·화학적 특성 (Electrochemical Characteristics of Supercapacitor Electrode Using MnO2 Electrodeposited Carbon Nanofiber Mats from Lignin-g-PAN Copolymer)

  • 김석주;유원재;김용식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권5호
    • /
    • pp.750-759
    • /
    • 2016
  • 크라프트 리그닌-polyacrylonitrile (PAN) 그라프트 공중합체의 전기방사 나노섬유매트를 열처리와 이산화망간($MnO_2$) 전기증착법을 이용하여 리그닌 기반 탄소나노섬유 매트(lignin based carbon nanofiber mat, LCNFM)로 제조하고, 슈퍼캐퍼시터용 전극소재(electrode)로의 응용가능성에 대하여 조사하였다. 전기증착 처리시간이 길수록 $MnO_2$-LCNFM 표면의 흡착되는 이산화망간양이 증가하였으며, 이에 따른 탄소나노섬유의 직경과 이산화망간 흡착층이 증가하였다. $MnO_2$-LCNFM 전극의 전기 화학적 특성을 순환전압전류측정(cyclic voltammetry)을 통해 평가하였고, 최대 $168.0mF{\cdot}cm^{-2}$의 비축적용량을 보였다. $MnO_2$-LCNFM를 이용하여 $H_3PO_4$/Polyvinyl alcohol 겔 전해질로 제작한 하이브리드 슈퍼캐퍼시터(hybrid supercapacitor)는 약 90%의 전기용량 효율(capacitance efficiency)을 보였으며, 1,000회의 충 방전 시험에서 안정적인 거동을 나타냈다.

Biopac 뇌파측정 장치를 이용한 학습의 효율성 분석 (The efficiency Analysis of study using brainwave measurement device)

  • 안영준;이충헌;박문규;지훈;이동훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 춘계학술대회
    • /
    • pp.951-953
    • /
    • 2015
  • 일상적으로 생각하는 학습이란, 연습이나 경험의 결과로 생기는 비교적 지속적인 유기체의 행동변화를 말한다. 학생들이 학습할 때 집중하면서 했다고 하지만 이를 객관적으로 평가하기란 매우 어렵다. 그러나 뇌파는 그렇지 않다. 뇌파란 뇌의 전기적 활동에 의해서 일어나는 두피상의 두 점 사이의 전위 변동을 연속적으로 기록한 것을 말한다. 종류로는 델타파(0~4Hz), 세타파(4~8Hz), 알파파(8~13Hz), 베타파(13~30Hz), 감마파(30~50Hz) 등이 있다. 그 중에서 SMR파(13~15Hz), Mid-베타파(16~20Hz)는 학습에 집중할 때 나타나며 집중력에 가장 영향을 주는 부분은 Mid-베타파라고 보고된 바 있다. 이와 관련하여 학습에 집중정도를 뇌파를 이용하여 객관적으로 평가할 수 있는 시스템에 관한 연구가 활발히 진행되고 있다. 본 연구는 Biopac 장비를 사용하여 소수의 피험자를 대상으로 학습 집중 주제를 준 후 뇌파를 측정한 다음 학습과 관련이 되는 Mid-베타파영역의 신호를 추출하기위해 FFT로 변환하였다. 집중할 때 Mid-베타파 주파수의 파워 변화를 측정하여 상관관계를 제시하고자 하였다. 이러한 결과를 바탕으로 학생들이 학습할 때 얼마나 집중하고 있는지 객관적으로 파악하여 좀 더 효율적으로 학업에 임하고 있는지 분석하였다.

  • PDF

직상류 계측유량경계조건과 분포형모델을 이용한 대규모 다목적댐 홍수유입량 산정 (Flood Inflow Estimation at Large Multipurpose Dam using Distributed Model with Measured Flow Boundary Condition at Direct Upstream Channels)

  • 홍석현;강부식
    • 대한토목학회논문집
    • /
    • 제35권5호
    • /
    • pp.1039-1049
    • /
    • 2015
  • 대규모 다목적댐 지점의 유입량 산정은 수위-저수용량곡선에 댐 축에서 측정된 수위를 적용하여 시간당 저수량변화를 계산한 후 방류량을 감안하여 산정하고 있으나, 이 방법은 태풍 등 대규모 홍수 시에는 급격한 유입량 증가로 인한 배수위 및 강한 바람 등의 영향으로 저수지내의 수위가 균일하지 않아 유입량 산정 시 오차 원인이 되고 있다. 이 외에 기존 수위-저수용량 곡선 방법에 의한 유입량 계산 시 문제점인 댐건설 이후 유입 퇴사로 인한 저수용량의 변화, 댐 지점에서의 수위관측의 불균일성 등 다양한 불확실성이 존재하므로 이에 대한 오차 규명이 반드시 필요하다. 본 연구에서는 저수지 유입량 분석시 분포형 강우유출모형을 이용한 UBC-3P 기법을 적용하여 모형의 모의능력을 평가하였다. 최종적으로 기존 유역내 유입량 관측치와 비교한 결과 Peak유량과 Total유량에서 결정계수가 0.82~0.99 사이값을 나타내므로 댐 지점에서의 모형의 적합성을 확인하였다.

On-site Water Nitrate Monitoring System based on Automatic Sampling and Direct Measurement with Ion-Selective Electrodes

  • Kim, Dong-Wook;Jung, Dae-Hyun;Cho, Woo-Jae;Sim, Kwang-Cheol;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • 제42권4호
    • /
    • pp.350-357
    • /
    • 2017
  • Purpose: In-situ monitoring of water quality is fundamental to most environmental applications. The high cost and long delays of conventional laboratory methods used to determine water quality, including on-site sampling and chemical analysis, have limited their use in efficiently managing water sources while preventing environmental pollution. The objective of this study was to develop an on-site water monitoring system consisting mainly of an Arduino board and a sensor array of multiple ion selective electrodes (ISEs) to measure the concentration of $NO_3$ ions. Methods: The developed system includes a combination of three ISEs, double-junction reference electrode, solution container, sampling system consisting of three pumps and solenoid valves, signal processing circuit, and an Arduino board for data acquisition and system control. Prior to each sample measurement, a two-point normalization method was applied for a sensitivity adjustment followed by an offset adjustment to minimize the potential drift that could occur during continuous measurement and standardize the response of multiple electrodes. To investigate its utility in on-site nitrate monitoring, the prototype was tested in a facility where drinking water was collected from a water supply source. Results: Differences in the electric potentials of the $NO_3$ ISEs between 10 and $100mg{\cdot}L^{-1}$ $NO_3$ concentration levels were nearly constant with negative sensitivities of 58 to 62 mV during the period of sample measurement, which is representative of a stable electrode response. The $NO_3$ concentrations determined by the ISEs were almost comparable to those obtained with standard instruments within 15% relative errors. Conclusions: The use of the developed on-site nitrate monitoring system based on automatic sampling and two-point normalization was feasible for detecting abrupt changes in nitrate concentration at various water supply sites, showing a maximum difference of $4.2mg{\cdot}L^{-1}$ from an actual concentration of $14mg{\cdot}L^{-1}$.

금속 코팅된 탄소나노튜브의 전계 방출 특성 및 신뢰성 향상 (Improvement of Electron Emission Characteristics and Emission Stability from Metal-coated Carbon Nanotubes)

  • 우형수;박상식;김병환
    • 한국진공학회지
    • /
    • 제20권6호
    • /
    • pp.436-441
    • /
    • 2011
  • 각종 전자 방출원 및 디스플레이 응용 분야에서 뛰어난 가능성을 보이고 있는 탄소나노튜브의 전계 방출 특성을 개선하고 전자방출의 신뢰성을 개선하기 위해 탄소나노튜브의 표면에 수 nm 두께의 금속 코팅을 적용하였다. 탄소나노튜브는 실리콘 기판위에 2 nm 두께의 Invar (52% Fe, 42% Ni, 6% Co alloy) 촉매를 사용하여 $450^{\circ}C$의 온도에서 플라즈마 화학기상 증착법으로 성장시켰다. 성장된 탄소나노튜브의 밀도 제어를 위해 성장 후 질소 플라즈마로 일부를 식각한 후 티타늄(Ti) 금속을 탄소나노튜브 표면에 5~150 nm 두께로 스퍼터링 증착하였다. 5 nm로 티타늄을 탄소나노튜브 표면에 코팅한 경우, 코팅 전에 비해 6 V/${\mu}m$의 전계에서 전류밀도가 4배 이상 증가되었으며, 전계 방출 전류의 요동(fluctuation) 또한 40% 이상 감소됨을 확인할 수 있었다. 이는 티타늄의 일함수가 4.3 eV로 탄소나노튜브의 5 eV에 비해 작을 뿐만 아니라, 탄소나노튜브의 약점으로 지적되는 기판과의 접착성과 접촉저항이 티타늄의 표면 코팅으로 인해 크게 개선된 결과로 판단된다.

원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구 (A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants)

  • 김경조;강석철;구철수;김진호;박재석;주금종;박치승
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.325-330
    • /
    • 2004
  • 원자력발전소에는 여러 종류의 케이블이 전력공급, 감시 및 제어신호의 전달을 위해 열악한 환경하에서 이용되고 있다. 발전소의 안전한 운전을 위해서 이 케이블이 어느 정도 열화 되었는지 확인할 필요가 있다. 특히, 원자력발전소의 수명 연장과 더불어 저압 케이블을 장기간 사용함에 따라서 저압케이블의 열화를 평가하기 위한 방법이 필요하게 되었다 저압케이블의 열화를 측정하는 파라미터로는 주변 온도, 절연재질의 경도, 파단시 연신률(EAB, Elongation At Breaking Point) 등이 있다. 그러나, 온도나 경도를 계측하는 검사는 정량적인 판단기준의 설정이 곤란하고 진단의 정밀도가 낮으며, 부분적으로 샘플링하는 방법은 샘플링되는 케이블에 연결된 부하를 정전시켜야 하고 장소와 시간적인 제약이 있으며, 전기적 측정법은 노화 초기부터 중기까지의 열화정도를 확인하기 어렵다. 본 연구에서는 재료의 열화에 따라서 초음파의 음속이 변화한다는 이론적인 배경(1,2)을 바탕으로 저압 케이블 재료의 열화에 따른 초음파의 음속을 측정하였다. 이를 위해, 원자력발전소에서 사용되는 저압케이블을 가속 열화시켰으며, 저압케이블의 피복재에서 초음파의 음속을 측정할 수 있는 장비를 개발하여, 초음파의 음속측정 후 인장시험을 통해 파단시 연신률을 측정하였다. 파단시 연신률이 증가함에 따라서 음속이 선형적으로 감소하였으며, 초음파의 음속은 열화의 정량적 평가 파라미터로서의 사용 가능성을 확인할 수 있었다.

우리나라 양곡가공공장의 현황분석 (The Profile of Milling Plants in Korea)

  • 정창주;금동혁;강화석
    • Journal of Biosystems Engineering
    • /
    • 제3권1호
    • /
    • pp.47-63
    • /
    • 1978
  • This study was conducted to obtain a basic information necessary to assess present rice milling technology in Korea The profiles for milling plants was analyzed by survey work.For the private custom-work mills, which process about 80 percent of domestic rice consumption ,their actual milling test for the identical samples as used for filed mills was conducted. Two rice varieties Japonica and Tongil-type were associated with the experiments. The results are summarized as follows: 1. Analyses for private custom-work mills showed their general aspects as; about 91 percent of the mills belonged to an individual owner ship ; more than 93 percent of the mills was established earlier than 1950 ; about 80 percent of the mills was powered with electric motor; mills having less than two employees were about 75 percent; about 45 percent of the mills provided for warehouse in storing customers cereal grains. 2. The polishers installed in 1,255mills within the surveyed area (7 counties) have been supplied by 44 different domestic manufacturers ;in but about 60 percent of which was supplied by 6major manufacturers. The polishers could be classified into two categories in terms of principles of their polishing actions ;jet-pearler and friction types. About 51 percent of the mills was equipped with the former which has been recognized as giving greater milling recovery than the friction types. 3. Reason for owners of private mills to supplement new machines was due mainly to pgrading their mills to meet the requirements that established by the Government. However, about 60 percent of the mill owners intended to replace with new pearler by their own needs to meet with new high yielding varieties. 4. Processing systems of each previate rice mills surveyed could be classified into three categories, depending upon whether the systems posessed such components as precleaner and paddy separator or not. Only 36.7 percent of mills was installed with both precleanr ad paddy seperrator, 5.0 percent of mills did have neither percleaner nor paddy seperator, and rest of them equipped only one of the two. Hence,it is needed for about 63% of rice miils to be supplemented with these basic facilities to meet with the requirements for the standaized system. 5. Actual milling capacity measured at each field rice mills was shown a wide variation, having range from about 190 to 1,210 kg/hr. The percentages of mills classified according to daily milling capacity based on this hourly capacity were 24.3% for the capacity less than 3 M/T a day; 20.0% for 3-4 M/T; 15.6% for 4-5 M/T; 6.7% for 5-6 M/T; 22.3% for 6-7 M/T; and 11.0% for more than 7 M/T a day. 6. Actual amount of rice processed was about 310 M/T a year in average. About 42% of total milled rice was processed during October to Decembear, which formed a peak demand period for rice mills. The amount of rice milled during January to May was relatively small, but it had still a large amount compared to that during June to September. 7. Utilization rate of milling facility, i. e., percentage of the actual amount of milled rice to the capacity of rice mills, was about 18% on the year round average, about 41% in the peak demand season, and about 10% during June to September. Average number of operating days for mills surveyed was about 250 days a year, and about 21 days a month. 8. Moisture contents of paddy at the time of field mill tests were ranged 14.5% to 19.5% for both Japonica and Tong-i] varieties, majority of paddy grains having moisture level much higher than 1530. To aviod potential reduction of milling recovery while milling and deterioration of milled rice while storage due to these high grain mJisture contents, it may be very important for farmers holding rice to dry by an artificial drying method. 9. Milling recovery of JapJnica varieties in rice mills was 75.0% in average and it was widely ranged from 69.0% to 78.0 % according to mills. Potential increase in milJing recovery of Japonica variety with improvement of mill facilities was estimated to about 1.9%. On the other hand, milling recovery of Tong-il varieties in the field mill tests was 69.8% in average and it ranged from 62% to 77 %, which is much wider than that of Japonica varieties. It is noticed that the average milling recovery of Tong-il variety of 69.8% was much less than that of the Japonica-type. It was estimated th3.t up to about 5.0% of milling recovery for Tong-il variety could be improved by improving the present lo'.ver graded milling technology. 10. Head rice recoveries, as a factor of representing the quality of commercial goods, of Japonica and Tong-il varieties were 65.9% and 53.8% in average, and they were widely ranged from 52% to 73% and from 44% to 65% , respectively. It was assessed that head rice recovery of Japonica varieties can be improved up 3.3% and that of Tong-il varieties by 7.0% by improving mill components and systems.

  • PDF