• 제목/요약/키워드: electric field measurement

검색결과 455건 처리시간 0.027초

고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads)

  • 김경철;진성은;이주홍;이일무;김주락
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.272-277
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the contol synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF

전기기구의 운전중에 발생되는 자계성분해석에 관한 연구 (A Study on the Analysis of the Magnetic Fields Generated by the operation of Electric Appliances)

  • 이복희;박형기;정승수;백용현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.575-577
    • /
    • 1993
  • In this study, the reponse characteristic of the time-changing magnetic field measurement system by using the self-integrated magnetic sensor is investigated. The measurement system has the frequency bandwidth of 40[Hz]-50[kHz]. The time-changing magnetic fields generated by the operations of small-size electric machines are investigated. The magnetic field generated by the starting and/or the operation of electric appliances mainly includes the odd harmonics such as the third, the fifth, the seventh, and so on.

  • PDF

Effective Volume of the Korea Research Institute of Standards and Science Free Air Chamber L1 for Low-Energy X-Ray Measurement

  • Chul-Young Yi;Yun Ho Kim;Don Yeong Jeong
    • 한국의학물리학회지:의학물리
    • /
    • 제33권1호
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: To evaluate the effective volume of the Korea Research Institute of Standards and Science free air chamber (KRISS FAC) L1 used for the primary standard device of the low-energy X-ray air kerma. Methods: The mechanical dimensions were measured using a 3-dimensional coordinate measuring machine (3-d CMM, Model UMM 500, Carl Zeiss). The diameter of the diaphragm was measured by a ring gauge calibrator (Model KRISS-DM1, KRISS). The elongation of the collector length due to electric field distortion was determined from the capacitance measurement of the KRISS FAC considering the result of the finite element method (FEM) analysis using the code QuickField v6.4. Results: The measured length of the collector was 15.8003±0.0014 mm with a 68% confidence level (k=1). The aperture diameter of the diaphragm was 10.0021±0.0002 mm (k=1). The mechanical measurement volume of the KRISS FAC L1 was 1.2415±0.0006 cm3 (k=1). The elongated length of the collector due to the electric field distortion was 0.170±0.021 mm. Considering the elongated length, the effective measurement volume of the KRISS FAC L1 was 1.2548±0.0019 cm3(k=1). Conclusions: The effective volume of the KRISS FAC L1 was determined from the mechanically measured value by adding the elongated volume due to the electric field distortion in the FAC. The effective volume will replace the existing mechanically determined volume in establishing and maintaining the primary standard of the low-energy X-ray.

전력케이블용 가교폴리에틸렌의 공간전하 극성측정기술에 관한 연구 (A Study on the Space Charge Polarity Measurement Teasurement Technology of Cross-Linked Polyethylene for Power Cable)

  • 국상훈;서장수;김병인;박중순
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권6호
    • /
    • pp.23-31
    • /
    • 1992
  • Charged particle in the polymers is supposed to affect the electrical conduction and to lead them th dielectrical breakdown finally. So we measured the space charge distribution made by application of high electric field and evaluated the polarity of the charged particle affected on electrical conduction and space charge formed in the insulating materials by using temperature gradient thermally stimulated current measurement method(TG-TSC measurement). As a result, in the cross-linked polyethylene, A-peak was caused from dipole polarization, C-peak was caused from ionic space charge polarization and D-peak was injected trap hole. Also we found it crossible the evaluated the polarity of injected trap carrier and electron(or hole) of carrier trap in the cross-lined polyethylene. We found that ${\gamma}$-ray irradiated low density polyethylene had a relation to the electronic trap and we also could get the value of electric field distribution in the samples of which evaluation was available.

  • PDF

시변전장 측정용 평판형 센서 (Planar-type Sensor for Measuring the Time-varying Electric Fields)

  • 이복희;길경석
    • 센서학회지
    • /
    • 제4권1호
    • /
    • pp.15-20
    • /
    • 1995
  • 본 논문은 시변전장을 측정할 수 있는 평판형 센서에 대하여 기술하였다. 광대역의 전장측정계를 구현하기 한 평판형 센서가 제안되었다. 측정계의 이론적인 원리와 설계방법에 대하여 제시하였으며, 교정실험 및 적용실험을 수행하였다. 교정실험을 통하여 전장측정계의 주파수대역과 감도는 $160\;[Hz]\;{\sim}\;25\;[MHz]$, 1.2 [mV/V/m] 이었다. 적용실험으로 고전압 실험실에서 임펄스전압과 진동성 과도전압에 의해 발생되는 전장을 제안된 측정장치로 측정하였으며, 측정결과는 우수하였다.

  • PDF

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.

현장실측에 의한 메시(Mesh)접지저항 출정기법 연구 (A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements)

  • 한기붕;김삼수;정세중;이상익
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

전력선통신을 위한 고압 배전선로의 방사전계강도 계산 (Calculation of Radiative Electric Field Intensity of Overhead Medium-Voltage Power lines for Power Line Communication)

  • 천동완;박영진;김관호;신철재
    • 한국통신학회논문지
    • /
    • 제30권12A호
    • /
    • pp.1136-1146
    • /
    • 2005
  • 본 논문에서는 전력선 통신을 위해 사용되는 고압 배전선로에서 통신신호 및 잡음신호에 의해 방사되는 방사전계강도를 계산하였다. 전력선 통신 네트워크의 2포트 등가모델 및 기본적인 전송선로 이론을 이용해 입력임피던스를 계산하였다. 그리고 계산된 입력임피던스를 이용해 전력선상 전류를 계산하고 최종적으로 방사전계강도를 계산하였다. 전력선의 특성임피던스가 매우커서 입력 단에서의 반사가 심하기 때문에 입력임피던스는 일정한 주기를 가지는 정재파 형태를 가진다. 계산된 전류 및 방사전계 또한 이러한 형태임을 알 수 있었다. 실제 측정한 결과계산 치와 측정치가 매우 유사함을 알 수 있었다.

Improvements to the stability of electric field sensors

  • Lee, Dong-Oh;Robert Boston;Dietrich W. Langer;Joel Falk
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.495-496
    • /
    • 1998
  • The measurement of the amplitude and phase of electric fields on high voltage transmission lines is important for several reasons including a) Metering and determination of power flow, b) protective relaying. and c) fault sensing. The work reported here is directed toward a major improvement to optically based, electric-field sensors. This is a signal processing based technique for overcoming the instabilities of conventional, optically-based, electric-field sensors to changes in optical power or temperature.

  • PDF

대지전계 측정을 위한 필드밀의 설계 및 제작 (Design and Fabrication of a Field Mill for Ground-Level Electric Field Measurement)

  • 길경석;송재용;김일권;권장우;안창환;이영근
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.52-59
    • /
    • 2007
  • 본 논문에서는 뇌경보시스템에 적용하기 위한 센서로 대지전계의 극성과 크기의 측정이 가능한 필드밀에 대하여 연구하였다. 회전날개를 갖는 평면 셔터형 필드밀을 설계 제작하였으며, 필드밀의 교정은 대칭적인 구조의 원형 평판전극을 수직으로 배열하고 이때 얻어지는 평등전계 내에서 수행하였다. 교정실험에서 필드밀의 감도를 0.5[V/kV/m]로 조정하였으며, 측정 가능한 대지전계의 범위는 $200[V/m]{\sim}]20[kV/m]$가 된다. 교정실험 후, 건물 옥상에 필드밀을 설치하고, 뇌운에 의한 대지전계의 변화를 관측하였다. 2006년 7월 1일부터 7월 15일의 기간 중, 뇌운의 생성과 소멸, 이동에 따라 대지전계의 크기는 $+2[kV/m]{\sim}-6[kV/m]$의 범위에서 기록되었다. 적용실험결과로부터 제안한 필드밀은 직류 전계 측정에 충분한 성능이 있음을 확인하였다.