• Title/Summary/Keyword: electric circuit modeling

Search Result 118, Processing Time 0.021 seconds

Dynamic Modeling of Piezoelectric Energy Harvesting Device and Experiments (압전 에너지 수집 장치의 동적모델링 및 실험)

  • Kwak, Moon-K.;Kim, Ki-Young;Kang, Ho-Yong;Kim, Nae-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.632-641
    • /
    • 2008
  • This paper is concerned with the development of the piezoelectric energy harvesting(PEH) device for ubiquitous sensor node(USN). The USN needs auxiliary power to lengthen its operational life. In this study, the piezoelectric energy harvesting system consisting of a cantilever with a tip mass and piezoelectric wafer was investigated in detail both theoretically and experimentally. The dynamic model for the addressed system was derived using the assumed mode method. The resulting equations of motion were expressed in matrix form, which had never been developed before. The power output characteristics of the PEH was then calculated and discussed. Various experiments were carried out to investigate the charging characteristics of electrical components. Theoretical and experimental results showed that the PEH was able to charge a battery with ambient vibrations but still needed an effective mechanism which can convert mechanical energy to electrical energy and an optimal electric circuit which dissipates small energy.

Design of Control System for LLC Resonant Converter (LLC 공진형 컨버터 제어시스템 설계)

  • Kim, Eui-Hyun;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.129-137
    • /
    • 2017
  • In this paper, we propose a digital controller design methodology for an LLC resonant converter which has been widely used due to the advantages of low switching loss and high efficiency. We establish a mathematical model of an LLC resonant converter using the extended describing function concept and propose a controller design method based on the Ziegler Nichols control parameter tuning criteria. The voltage controller of an LLC resonant converter is designed based on the derived small signal model and the performance of the controller is verified by MATLAB simulations. The validity and the control performance of the designed voltage controller for the LLC resonant converter is analyzed through some simulations for the case of load variations and circuit modeling errors.

A Study on the Hydraulic Vibration Characteristics of the Prefill Check Valve (프리필용 체크밸브의 유압진동 특성에 관한 연구)

  • Park, Jeong Woo;Han, Sung-Min;Lee, Hu Seung;Yun, So-Nam
    • Journal of Drive and Control
    • /
    • v.18 no.3
    • /
    • pp.8-15
    • /
    • 2021
  • A rear axle steering (RAS) system is attached to the rear of medium and large commercial vehicles that transport large cargo. The existing RAS systems are driven by electro-hydraulic actuator (EHA), and most commercialized EHAs consist of electric motors, hydraulic pumps, relief valves, prefill valves and cylinders. The prefill valve required for such EHAs is a type of check valve with extremely low cracking pressure that should not allow RAS to have noise or vibration, and the prefill valve prevents system negative pressure as well as unstable operation. Most papers on this topic rely on experiments to predict valve performance, and theoretically detailed modeling of valves or pipelines is performed, but it is very rare to evaluate hydraulic vibration characteristics by analysing everything from hydraulic pumps to valves comprehensively. In this study, we proposed an experimental circuit that can predict the performance of the prefill valve. The study also analysed the pressure-flow pulsation that is transmitted to the valve through the pipeline, and how the transmitted pressure-flow pulsation affects the valve vibration.

Evaluation Method for Protection Coordination of PV Systems Interconnected with Primary Feeders (태양광전원이 연계된 고압배전선로의 보호협조 평가 방안에 관한 연구)

  • Kim, Byungki;Kim, Sohee;Ryu, Kyungsang;Rho, Daeseok
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.4
    • /
    • pp.29-37
    • /
    • 2011
  • Dispersed generation (DG) such as wind power (WP) and Photovoltaic systems (PV) that has been promoted at the national level recently is mainly being introduced into distribution systems adjacent to consumers because it is generation on a small scale when compared to current generation. Due to its characteristics, DG can be operated by interconnection with distribution systems to present security of more stable power and efficient use of power facilities and resources. Problems on protection coordination of distribution systems by reverse flow of DG can roughly be divided into three possibilities: excess in rated breaking capacity (12.5KA) of protective devices by a fault in DG current supply, failure to operate protective devices by an apparent effect that can occur by reduction in impedance parallel circuit fault current due to interconnection of DG, and malfunction of protective devices by interconnection transformer connection type. The purpose of this study is to analyze problems in protection coordination that can occur when DG is operated by interconnection with distribution systems by conducting modeling and simulations by using theoretical symmetrical components and MATLAB/SIMULINK to present methods to improve such problems.

Convergence Comparison of Linear Oscillating Electric Machines (리니어 오실레이팅 전기기기의 비교 연구)

  • Jeong, Sung-In;Eom, Sang In
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.273-280
    • /
    • 2021
  • This paper presents the results of study of linear oscillating electric machine; Cartesian, cylindrical type with permanent magnet, flux reversal, cylindrical reluctance, and transverse flux type. The focus of the work is the suggestion of the characteristics and design process of propose topology, respectively. First of all, there are five types of the proposed to this study on the basis of the existing literatures; Cartesian type, cylindrical type, flux reversal type, cylindrical reluctance type, and transverse flux type. All topology is achieved using equivalent magnetic circuit considering leakage elements as initial modeling. Cartesian type is investigated by number of phases and number of pole pairs using optimal process. A cylindrical type is described by number of phases and displacement of stroke. The flux reversal type is proposed based on the symmetrical and non symmetrical stator cores of the surface mounted PMs mover, and non slanted PMs and slanted PMs of the flux concentrating PMs mover. A cylindrical reluctance type is studied by the shape of mover teeth in geometric aspect to reduce force ripple and increase magnetic flux. A transverse flux type is considered by dividing the transverse flux electric excited and the transverse flux permanent magnet excited. It is significant that the study gives a design rules and features of linear oscillating electric machine.

Calculation of Induced Current in the Human Body around 765 kV Transmission Lines (765 kV 초고압 송전선 주변의 인체 유도전류 계산)

  • 명성호;이재복;허창수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.6
    • /
    • pp.802-812
    • /
    • 1998
  • Safety related to electric field exposure for the personnel of high voltage power plant and substation is of importance. To analyze the induced current influencing on human body in this paper, we calculate directly capacitance in three dimension which is complex and time consuming, as not to separate the voltage source and the induced object using a effective modeling technique. The proposed algorithm in this paper has been applied to 765 kV high voltage transmission line to evaluate human hazard for the induced current through the case study. As the results, the short circuit current of human body has been identified in the range of 0.3 mA to 6.8 mA. Closing to transmission line, this range of short current can exceed 5 mA that ANSI recommended let-go current. Therefore, it is necessary to countermeasure such as putting on conductive clothing in live-line maintenance of transmission line.

  • PDF

Modeling and Simulation of the Total Artificial Heart with Cardiovascular System (심혈관계를 포함한 인공심장의 모델링 및 컴퓨터 시뮬레이션)

  • Park, J.W.;Park, S.K.;Choi, J.H.;Jo, Y.H.;Choi, J.S.;Ahn, J.M.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.249-250
    • /
    • 1998
  • In this study, we modeled moving-actuator type Total Artificial Heart (TAH) with cardiovascular system as a form of electric circuit. The bronchial circulation, important for the imbalance between the left cardiac output and the right one, was considered and added to the model. In the model, the relations of hemodynamic variables, just as blood pressures, volumes, or flow rates of each part of body, can be expressed as simultaneous first order ordinary differential equations. To solve the equations by the numerical analysis, Runge-Kutta forth order approximation method was adopted. The simulation software (SimTAH), implemented in C++ as a window-based application program, was developed to display the hemodynamic variables and to receive control inputs from users. SimTAH was evaluated by comparison of the simulation results with the results of mock-circulation tests, in vitro.

  • PDF

Modeling and Simulation of the Cardiovascular System Using Baroreflex Control Model of the Heart Activity (심활성도 압반사 제어 모델을 이용한 심혈관시스템 모델링 및 시뮬레이션)

  • Choi Byeong Cheol;Jeong Do Un;Shon Jung Man;Yae Su Yung;Kim Ho Jong;Lee Hyun Cheol;Kim Yun Jin;Jung Dong keun;Yi Sang Hun;Jeon Gye Rok
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.565-573
    • /
    • 2004
  • In this paper, we proposed a heart activity control model for simulation of the aortic sinus baroreceptor, which was the most representative baroreceptor sensing the variance of pressure in the cardiovascular system. And then, the heart activity control model composed electric circuit model of the cardiovascular system with baroreflex control and time delay sub-model to observe the effect of time delay in heart period and stroke volume under the regulation of baroreflex in the aortic sinus. The mechanism of time delay in the heart activity baroreflex control model is as follows. A control function is conduct sensing pressure information in the aortic sinus baroreceptor to transmit the efferent nerve through central nervous system. As simulation results of the proposed model, we observed three patterns of the cardiovascular system variability by the time delay. First of all, if the time delay over 2.5 second, aortic pressure and stroke volume and heart rate was observed non-periodically and irregularly. However, if the time delay from 0.1 second to 0.25 second, the regular oscillation was observed. And then, if time delay under 0.1 second, then heart rate and aortic pressure-heart rate trajectory were maintained in stable state.