• 제목/요약/키워드: electric charges

검색결과 189건 처리시간 0.024초

Influense of the high-voltage conductivity on peculiarity of polarization ferroelectric polymer on based vinylidenefluoride

  • Kochervinskii, V.V.;Chubunova, E.V.;Lebedinskii, Y.Y.;Pavlov, A.S.;Pakuro, N.I.
    • Advances in materials Research
    • /
    • 제4권2호
    • /
    • pp.113-132
    • /
    • 2015
  • The phenomena of high-voltage polarization and conductivity in oriented vinylidenefluoride and tetrafluoroethylene copolymer films have been investigated. It was shown that under certain electric fields, injection of carriers from the material of electrodes appears The barrier for holes injection in the copolymer was found to be lower than that for electrons. It results in more effective screening of the external field near the anode than near cathode. Electrones, ejected from cathode, creating negative charge by trapping on the surface. It is shown that the electrons injected from cathodes create a negative homocharge on the copolymer surface and then become captured on the surface shallow traps. Their nature has been studied by the x-ray photoelectron spectroscopy. It was shown that these traps may consist of chemical defects in the form of new functional groups formed by reactions of surface macromolecules with sputtered atoms of aluminum. The asymmetric shape of hysteresis curves was explained by the difference in mobility of injected holes and electrons. These factors caused appearance of "non-closed" hysteresis curves for fluorine-containing polymer ferroelectrics. Hysteresis phenomena observed at low electric fields (below coercive ones) are to associate with the behavior of the domains localized in the ordered regions formed during secondary crystallization of copolymers.

침-평판 전극 사이에서 중간 압력 질소 방전의 시뮬레이션 (Numerical Simulation of Nitrogen Discharge at Medium Pressure between Point-Plane Electrodes)

  • 고욱희;박인호
    • 한국진공학회지
    • /
    • 제17권6호
    • /
    • pp.487-494
    • /
    • 2008
  • 준 2차원 수치적 모델을 사용하여 침-평판(point-plane)형의 전극 사이에 있는 중간 압력 질소의 방전에 대한 시뮬레이션을 수행하였다. 이 모델에서는 전자와 이온에 대한 연속방정식을 풀어 시. 공간적으로 변하는 전하분포를 계산하고, 공간 전하 분포의 변화에 따라 결정되는 전기장은 푸아송 방정식을 풀어 얻는다. 연속 방정식은 FCT (Flux-corrected transport) 알고리즘과 FEM (Finite Element Method) 방법을 적용하여 수치적으로 다루어 졌다. 50Torr 압력에서의 질소 방전에 대한 시뮬레이션 결과는 중간 압력 질소 방전의 물리적 특성에 관한 상세한 이해를 제공한다. 또 계산 결과와 실험 결과[1]와의 비교는 정성적으로 잘 일치하는 것을 보여 준다.

표면 전하에 의한 Thyristor 소자의 차단전압 및 누설전류특성 연구 (Study on the Blocking Voltage and Leakage Current Characteristic Degradation of the Thyristor due to the Surface Charge in Passivation Material)

  • 김형우;서길수;방욱;김기현;김남균
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권1호
    • /
    • pp.34-39
    • /
    • 2006
  • In high-voltage devices such as thyristor, beveling is mostly used junction termination method to reduce the surface electric field far below the bulk electric field and to expand the depletion region thus that breakdown occurs in the bulk of the device rather than at the surface. However, coating material used to protect the surface of the device contain so many charges which affect the electrical characteristics of the device. And device reliability is also affected by this charge. Therefore, it is needed to analyze the effect of surface charge on electrical characteristics of the device. In this paper, we analyzed the breakdown voltage and leakage current characteristics of the thyristor as a function of the amount of surface charge density. Two dimensional process simulator ATHENA and two-dimensional device simulator ATLAS is used to analyze the surface charge effects.

직류 코로나 하전된 강유전체구 층의 연면방전특성 (Surface Discharge Characteristics of a DC Corona Charged Ferroelectric Pellet Barrier)

  • 금상택;이근택;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.385-390
    • /
    • 1999
  • Surface corona discharge characteristics of a dc corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charges stored on the surfaces of the ferroelectric pellets by a dc corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between corona tip and mesh electrode. Positive and negative dc voltages were applied to the tip to generate partial discharges, and corona currents were estimated to investigate the buildup charge on ferroelectric pellets as a function of the applied time and the charge relaxation time constants of ferroelectric pellets. As a result, in the case of the negative corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be fenerated efficiently. It is also found that, charge relaxation time, dielectric constants offerroelectric pellets, polarity of applied voltage and applied time affected to the surface discharges among the ferroelectric pellets.

  • PDF

전기방사법으로부터 제조된 $TiO_2$ 섬유 복합전극의 충방전 특성 (Charge-discharge Characteristics of $TiO_2$-Activated Carbon Composite Electrode using Electrospinning)

  • 안민선;김한주;손원근;;박수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2022-2024
    • /
    • 2005
  • Electrical double-layer capacitor (EDLC) is an electrochemical energy storage device in which electric charges only accumulated by a pure electrostatic attraction force are stored on the electrolyte-electrode interface in a form of double layer and separated by the electrolyte. The composite was prepared by mixing nanosize $TiO_2$ and activated carbon through a means of ultrasonic vibration in ethanol solution for 30 min in various mass ratios of $AC:TiO_2$ to form activated carbone-semiconducting oxide composites. Either 1.0 M $LiClO_4/EC-DEC$ or $Et_4NBF_4$/EC-DEC was used as the electrolyte. It was found that with modification of $TiO_2$, the specific capacitance of activated carbon measured at $1mA/cm^2$ was increased from 40 to 50 F/g. This method is unique in comparison the conventional method because it uses semiconducting TiO2 other than electrochemically active materials such as $RuO_2$. The increase in specific capacitance could be attributed to the decrease in electric polarization, caused by the introduction of $RuO_2$.

  • PDF

The Effective Capacitance of a Constant Phase Element with Resistors in Series

  • Byoung-Yong, Chang
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권4호
    • /
    • pp.479-485
    • /
    • 2022
  • The power of energy storage devices is characterized by capacitance and the internal resistance. The capacitance is measured on an assumption that the charges are stored at the electrode interface and the electric double layer behaves like an ideal capacitor. However, in most cases, the electric double layer is not ideal so a constant phase element (CPE) is used instead of a capacitor to describe the practical observations. Nevertheless, another problem with the use of the CPE is that CPE does not give capacitance directly. Fortunately, a few methods were suggested to evaluate the effective capacitance in the literature. However, those methods may not be suitable for supercapacitors which are modeled as an equivalent circuit of a CPE and resistor connected in series because the time constant of the equivalent circuit is not clearly studied. In this report, in order to study the time constant of the CPE and find its equivalent capacitor, AC and DC methods are utilized in a complementary manner. As a result, the time constants in the AC and DC domains are compared with digital simulation and a proper equation is presented to calculate the effective capacitance of a supercapacitor, which is extended to an electrochemical system where faradaic and ohmic processes are accompanied by imperfect charge accumulation process.

전기차 충전인프라 및 데이터 연계 분석에 의한 시스템 모델링 및 실증 설계 (Novel System Modeling and Design by using Eclectic Vehicle Charging Infrastructure based on Data-centric Analysis)

  • 김항섭;박호민;정태경;이웅재
    • 인터넷정보학회논문지
    • /
    • 제20권2호
    • /
    • pp.51-59
    • /
    • 2019
  • 본 논문은 최근 각광받고 있는 전기차위주의 많은 실증 사업 중 충전 인프라와 연계된 충전운영시스템 및 전기요금간의 관계를 데이터 연계 분석하였다. 현 시점에서 앞으로 일어날 전기차 충전 인프라에 대한 급속한 수요의 증가로 말미암아 수요치를 예측한다는 의미에서 다가오는 시대를 미리 준비 할 수 있다. 동시에 시스템 모델링을 사이트를 중심으로 실증하고 도식화하는 일이 선행되어야 할 요소이다. 기존의 소규모 시뮬레이션에 의한 모델링과 운영시스템의 설계는 데이터 연계분석을 기반으로 하였다. 본 논문에서는 최종적으로 새로운 시스템 모델링을 구현하여 실제 차량과 이용자를 대상으로 각 지점과 노드별로 시간에 따른 시분할 데이터로 분석하고자 표준 형식으로 도입하였다. 실제 구현된 전기차 충전 인프라와 운영시스템을 대상으로 데이터 연계분석 중심의 효율성을 증명하고자 하였다.

조지훈의 시 「선(線)」으로 비유되는 시냅스 활성화의 의미 구조 (The Semantic Structure of Synaptic Activation, Likened to Cho Ji-Hoon's Poem 'Line')

  • 박인과
    • 문화기술의 융합
    • /
    • 제3권4호
    • /
    • pp.21-26
    • /
    • 2017
  • 이 연구는 조지훈의 시 "선(線)"에 대입되는 신경생리학적 치유의 구조를 분석하여 문학치료 프로그램에 활용할 목적으로 진행되었다. 연구 결과 인체에서의 활동전위가 마음을 표상하는 것으로 보인다. 즉 전기적 성격을 띤 전하들이 마음의 부호들로 보이며, 인체의 모든 전하들의 활동전위가 함께 종합되어 마음을 체계화하는 것으로 보인다. 조지훈의 시 "선(線)"은 인체의 신경생리학적인 시냅스의 기능인 정보수집과 분석 종합, 정보의 재생산에 대한 과정을 닮아있다. 이는 문학치료 프로그램에 대한 활용도 측면에서 유용한 시의 형태이다. 이러한 조지훈의 시와 같은 형태의 문학치료 프로그램을 개발한다면 치유의 과정에서 보다 효율적인 결과를 가져올 수 있을 것으로 사료된다.

Effects of Spray Surfactant and Particle Charge on Respirable Coal Dust Capture

  • Tessum, Mei W.;Raynor, Peter C.
    • Safety and Health at Work
    • /
    • 제8권3호
    • /
    • pp.296-305
    • /
    • 2017
  • Background: Surfactant-containing water sprays are commonly used in coal mines to collect dust. This study investigates the dust collection performance of different surfactant types for a range of coal dust particle sizes and charges. Methods: Bituminous coal dust aerosol was generated in a wind tunnel. The charge of the aerosol was either left unaltered, charge-neutralized with a neutralizer, or positively- or negatively-charged using a diffusion charger after the particles were neutralized. An anionic, cationic, or nonionic surfactant spray or a plain water spray was used to remove the particles from the air flow. Some particles were captured while passing through spray section, whereas remaining particles were charge-separated using an electrostatic classifier. Particle size and concentration of the charge-separated particles were measured using an aerodynamic particle sizer. Measurements were made with the spray on and off to calculate overall collection efficiencies (integrated across all charge levels) and efficiencies of particles with specific charge levels. Results: The diameter of the tested coal dust aerosol was $0.89{\mu}m{\pm}1.45$ [geometric $mean{\pm}geometric$ standard deviations (SD)]. Respirable particle mass was collected with $75.5{\pm}5.9%$ ($mean{\pm}SD$) efficiency overall. Collection efficiency was correlated with particle size. Surfactant type significantly impacted collection efficiency: charged particle collection by nonionic surfactant sprays was greater than or equal to collection by other sprays, especially for weakly-charged aerosols. Particle charge strength was significantly correlated with collection efficiency. Conclusion: Surfactant type affects charged particle spray collection efficiency. Nonionic surfactant sprays performed well in coal dust capture in many of the tested conditions.

무효전력시장을 이용한 무효전력서비스 요금 산정방법의 비교 및 새로운 방안 (Comparison of Methods for Calculating Reactive Power Service Charge and Proposing a New Method using Reactive Power Markets)

  • 노경수;최준호
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.78-84
    • /
    • 2006
  • 전력산업이 수직독점적인 구조에서 규제완화의 경쟁체제로 전환됨에 따라 무효전력서비스의 요금산정이 전력시장 운영자에게는 새로운 이슈가 되고 있다. 본 논문은 몇몇의 선진국과 국내에서 채용되는 무효전력서비스에 대한 요금산정방법을 검토하고, 무효전력시장을 이용하는 새로운 요금산정방법을 제안한다. 무효전력시장은 무효전력 발전원이 제시하는 입찰값을 바탕으로 하루전 전력시장 후에 무효전력 최적조류계산을 거쳐 단일가격으로 결정된다. 제안하는 방법은 무효전력 설치용량에 대한 투자비뿐만 아니라 무효전력 생산량을 늘리기 위해 발전기가 줄이게 되는 유효전력에 대한 기회비용을 함께 고려하고 있다. 26모선 모델계통에서의 사례연구를 통하여 제안하는 방법의 효용성을 입증하고 있다.