• 제목/요약/키워드: elastic lateral stiffness

검색결과 119건 처리시간 0.024초

An Overview on Performamce Control and Efficient Design of Lateral Resisting Moment Frames

  • Grigorian, Mark;Grigorian, Carl E.
    • 국제초고층학회논문집
    • /
    • 제2권2호
    • /
    • pp.141-152
    • /
    • 2013
  • This paper presents a brief overview of the recently developed performance-control method of moment frame design subjected to monotonously increasing lateral loading. The final product of any elastic-plastic analysis is a nonlinear loaddisplacement diagram associated with a progressive failure mechanism, which may or may not be as desirable as expected. Analytically derived failure mechanisms may include such undesirable features as soft story failure, partial failure modes, overcollapse, etc. The problem is compounded if any kind of performance control, e.g., drift optimization, material savings or integrity assessment is also involved. However, there is no reason why the process can not be reversed by first selecting a desirable collapse mechanism, then working backwards to select members that would lead to the desired outcome. This article provides an overview of the newly developed Performance control methodology of design for lateral resisting frameworks with a view towards integrity control and prevention of premature failure due to propagation of plasticity and progressive P-delta effects.

Energy absorption of foam-filled lattice composite cylinders under lateral compressive loading

  • Chen, Jiye;Zhuang, Yong;Fang, Hai;Liu, Weiqing;Zhu, Lu;Fan, Ziyan
    • Steel and Composite Structures
    • /
    • 제31권2호
    • /
    • pp.133-148
    • /
    • 2019
  • This paper reports on the energy absorption characteristics of a lattice-web reinforced composite sandwich cylinder (LRCSC) which is composed of glass fiber reinforced polymer (GFRP) face sheets, GFRP lattice webs, polyurethane (PU) foam and ceramsite filler. Quasi-static compression experiments on the LRCSC manufactured by a vacuum assisted resin infusion process (VARIP) were performed to demonstrate the feasibility of the proposed cylinders. Compared with the cylinders without lattice webs, a maximum increase in the ultimate elastic load of the lattice-web reinforced cylinders of approximately 928% can be obtained. Moreover, due to the use of ceramsite filler, the energy absorption was increased by 662%. Several numerical simulations using ANSYS/LS-DYNA were conducted to parametrically investigate the effects of the number of longitudinal lattice webs, the number of transverse lattice webs, and the thickness of the transverse lattice web and GFRP face sheet. The effectiveness and feasibility of the numerical model were verified by a series of experimental results. The numerical results demonstrated that a larger number of thicker transverse lattice webs can significantly enhance the ultimate elastic load and initial stiffness. Moreover, the ultimate elastic load and initial stiffness were hardly affected by the number of longitudinal lattice webs.

Extension of Direct Displacement-Based Design to Include Higher-Mode Effects in Planar Reinforced Concrete Frame Buildings

  • 아베베 베카 하일루;이종세
    • 한국지진공학회논문집
    • /
    • 제22권5호
    • /
    • pp.299-309
    • /
    • 2018
  • Now that problems with force-based seismic design have been clearly identified, design is inclined toward displacement-based methods. One such widely used method is Direct-Displacement-Based Design (DDBD). Yet, one of the shortcomings of DDBD is considering higher-mode amplification of story shear, moments, and displacements using equations obtained from limited parametric studies of regular planar frames. In this paper, a different approach to account for higher-mode effects is proposed. This approach determines the lateral secant stiffness of the building frames that fulfill the allowable inter-story drift without exceeding the desired story displacements. Using the stiffness, an elastic response spectrum analysis is carried out to determine elastic higher-mode force effects. These force effects are then combined with DDBD-obtained first-mode force effects using the appropriate modal superposition method so that design can be performed. The proposed design procedure is verified using Nonlinear Time History Analysis (NTHA) of twelve planar frames in four categories accounting for mass and stiffness irregularity along the height. In general, the NTHA response outputs compared well with the allowable limits of the performance objective. Thus, it fulfills the aim of minimizing the use of NTHA for planar frame buildings, thereby saving computational resources and effort.

Evaluation of monotonic and cyclic behaviour of geotextile encased stone columns

  • Ardakani, Alireza;Gholampoor, Naeem;Bayat, Mahdi;Bayat, Mahmoud
    • Structural Engineering and Mechanics
    • /
    • 제65권1호
    • /
    • pp.81-89
    • /
    • 2018
  • Stone column installation is a convenient method for improvement of soft ground. In very soft clays, in order to increase the lateral confinement of the stone columns, encasing the columns with high stiffness and creep resistant geosynthetics has proved to be a successful solution. This paper presents the results of three dimensional finite element analyses for evaluating improvement in behaviour of ordinary stone columns (OSCs) installed in soft clay by geotextile encasement under monotonic and cyclic loading by a comprehensive parametric study. The parameters include length and stiffness of encasement, types of stone columns (floating and end bearing), frictional angle and elastic modulus of stone column's material and diameter of stone columns. The results indicate that increasing the stiffness of encasement clearly enhances cyclic behaviour of geotextile encased stone columns (GESCs) in terms of reduction in residual settlement. Performance of GESCs is less sensitive to internal friction angle and elasticity modulus of column's materials in comparison with OSCs. Also, encasing at the top portion of stone column up to triple the diameter of column is found to be adequate in improving its residual settlement and at all loading cycles, end bearing columns provide much higher resistance than floating columns.

정적 탄소성 해석에 의한 고층 벽식 아파트의 수평내력 검토 (Evaluation of Lateral Load Resistance Capacity of a High-rise Shear Wall Apartment Based on Elasto-plastic Analaysis)

  • 전대한;강호근;조한욱;이정원
    • 한국지진공학회논문집
    • /
    • 제2권4호
    • /
    • pp.31-40
    • /
    • 1998
  • 본 연구에서는 등가 정적 지진하중을 받는 고층 벽식구조물의 거동을 파악하고자 탄소성해석을 수행하고 극한 수평내력을 평가하였다 해석 대상 건물로 현재 국내에서 분양되고 있는 두세대로 이루어진 25층 고층벽식 아파트 평면 형식을 선정하였다 3차원 정적 탄소성 입체 해석 프로그램(CANNY)을 이용하여 벽식 아파트 건물의 층별 초기 탄성강성 항복후 항복강성, 종국 내력 등을 평가한다 정적 탄소성 해석결과 해석대상 해석대상 아파트 건물의 항복내력은 설계용 등가 정적 지진하중의 1.6배 정도의 여유를 가지고 있음을 보여준다.

  • PDF

Seismic upgrading of reinforced concrete frames with steel plate shear walls

  • Korkmaz, Hasan H.;Ecemis, Ali S.
    • Earthquakes and Structures
    • /
    • 제13권5호
    • /
    • pp.473-484
    • /
    • 2017
  • The objective of this paper is to report on a study of the use of unstiffened thin steel plate shear walls (SPSWs) for the seismic performance improvement of reinforced concrete frames with deficient lateral rigidity. The behaviour of reinforced concrete frames during seismic activities was rehabilitated with an alternative and occupant-friendly retrofitting scheme. The study involved tests of eight 1/3 scale, one bay, two storey test specimens under cyclic quasi-static lateral loadings. The first specimen, tested in previous test program, was a reference specimen, and in seven other specimens, steel infill plates were used to replace the conventional infill brick or the concrete panels. The identification of the load-deformation characteristics, the determination of the level of improvement in the overall strength, and the elastic post-buckling stiffness were the main issues investigated during the quasi-static test program. With the introduction of the SPSWs, it was observed that the strength, stiffness and energy absorption capacities were significantly improved. It was also observed that the experimental hysteresis curves were stable, and the composite systems showed excellent energy dissipation capacities due to the formation of a diagonal tension field action along with a diagonal compression buckling of the infill plates.

궤도시스템의 횡탄성에 따른 곡선부 레일의 동적거동평가 (A Dynamic Behavior Evaluation of the Curved Rail according to Lateral Spring Stiffness of Track System)

  • 김박진;최정열;천대성;엄맥;강윤석;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.517-528
    • /
    • 2007
  • 곡선부 열차주행시 궤도에 작용하는 횡압은 궤도 변형과 차량손상 및 유지보수 비용 증가를 초래하며 특히 곡선부 레일의 편마모 및 열화손상에 직접적인 영향을 미친다. 그러나 국내외적으로 이러한 레일손상에 미치는 여러요인에 대한 기존의 연구는 선형, 차량조건, 운전속도 및 운전습관 등에 집중되어 있으며 궤도구조의 특성(탄성력, 유지관리 등)에 관한 것은 간과하고 있는 실정이다. 또한 자갈도상 궤도구조에서 도상 횡저항력이라 부르는 궤도의 횡탄성이 콘크리트 궤도에서는 특별히 없기 때문에 일반적으로 콘크리트 궤도구조가 자갈도상 궤도보다 마모로 인한 레일 교체주기가 약 2배 짧은 것으로 기존의 연구결과 나타났으며, 국내 콘크리트 궤도 설계 및 운영 실적 검토결과 콘크리트 궤도의 궤도탄성력이 자갈도상보다 부족하여 레일 및 궤도손상을 가중 시키고 있는 것으로 나타났다. 일반적으로 콘크리트 궤도는 자갈도상 궤도에 비해 궤도의 탄성조정이 유리하며 유럽의 경우 콘크리트 궤도 설계 시 자갈도상의 수직 탄성력 범위와 동등이상의 성능확보를 권고하고 있으나 국내외적으로 궤도의 횡탄성에 대한 검토는 미약한 수준이다. 따라서 본 연구에서는 운행선 궤도에서의 현장측정 및 유지관리실적 분석을 통해 공용중인 자갈도상 및 콘크리트 궤도의 동적거동 특성을 파악하여 운행선 궤도의 탄성력을 유추하고 궤도시스템별 궤도 탄성력과 레일 손상과의 상관관계 및 곡선부 레일 손상에 미치는 궤도 횡탄성의 영향을 실험적으로 입증하여 콘크리트 궤도의 적정 탄성 수준 및 자갈도상 궤도의 도상탄성 확보의 중요성을 제시하고자 한다.고리즘 보다 DNA 염기 서열 배치에 있어서 효율적임을 확인하였다.첨의 폐쇄를 유도할 수 있었고 이런 점을 이용 외과적 술식을 피할 수 있었다. 2군 사이에는 통계학적 차이가 없었다(p>0.05). 4. 치은면에서 $Oraseal^{(R)}$을 이용하여 수복한 3군이 1, 2군보다 통계학적으로 더 낮은 미세누출 정도를 보였다(p<0.05).하였다. 생징후의 경우 각 군 모두 정상범위 내에서 안정된 양상을 보였으나, 개구기 삽입이나 국소마취 단계에서 발생하는 자극에 대한 말초 동맥혈 산소포화도와 심박수의 반응정도가 I군에 비해 II군에서 낮게 나타났다(p<0.05). 임상적으로 바람직한 행동양상(Q : Quiet)의 비율이 III군에 비해 II군에서 높게 나타났으며(p<0.05), II군과 I군간에는 유의한 차이를 보이지 않았다 (p>0.05). 본 실험에서 시도한 두 가지 진정요법이 비교적 높은 임상적 치료 성공률(II군 : 97.14%, III군 : 88.57%)을 보여 만족할 만한 결과를 나타낸 것으로 평가되었다.tosan film보다 큰 수증기 투과도를 보였다.적으로 유의한 차이를 보이지 않았다.y tissue layer thinning은 3 군모두에서 관찰되었고 항암 3 일군이 가장 심하게 나타났다. 이상의 실험결과를 보면 술전 항암제투여가 초기에 시행한 경우에는 조직의 치유에 초기 5 일정도까지는 영향을 미치나 7 일이 지나면 정상범주로 회복함을 알수 있었고 실험결과 항암제 투여후 3 일째 피판 형성한 군에서 피판치유가 늦어진 것으로 관찰되어 인체에서

  • PDF

유연한 보구조물의 탄성유한요소해석 (Elastic Finite Element Analysis for a Flexible Beam Structure.)

  • 정동원;임세영
    • 대한기계학회논문집A
    • /
    • 제20권11호
    • /
    • pp.3441-3453
    • /
    • 1996
  • A finite element anlaysis is performed for large deformations of a felxible beam. The total Lagrangian formulation for a general large deformation, which involves finite rotations, is chosen and the exponential map is used to treat finite rotations from the Eulerian point of view. The finite elements results are confirmed for several cases of deformations through comparison to a first order elasticity solution obtained by numerical integration, and the agreement between the two is found to be excellent. For lateral buckling, the point of vanishing determinant of the resulting unsymmetric tangent stiffness is traced to examine its relationship to bifurcation points. It is found that the points of vanishing determinant is not corresponding to bifurcation points for large deformation in general, which suggests that the present unsymmetric tangent stiffness is not an exact first derivative of internal forces with respect to displacement.

X, Y 방향에 따른 상부벽식-하부골조의 비선형 정적응답특성 (The Response Characteristics of Nonlinear Pushover Analysis of Upper Wall-Lower Frame System with X and Y-Directions)

  • 강병두;전대한;김재웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 2003
  • The purpose of this study is to investigate the response characteristics of pushover analysis of upper wall-lower frame system with X and Y-directions' lateral load Pushover analysis estimates initial elastic stiffness, post-yielding stiffness, and plastic hinges on each story of structures through three-dimensional nonlinear analysis program. The conclusions of this study are as follows; (1) As a result of pushover analysis, the magnitude of nonlinear response and distribution of yield hinge in lower structure are similar with both X and Y directions, but not in upper structure because of different relative stiffness. (2) The maximum drift ratio of roof is larger for X-direction than for Y-direction with respect to magnitude of shear wall areas in upper structure.

  • PDF

Design aspects for minimizing the rotational behavior of setbacks buildings

  • Georgoussis, George K.
    • Earthquakes and Structures
    • /
    • 제10권5호
    • /
    • pp.1049-1066
    • /
    • 2016
  • An approximate analysis is presented for multi-story setback buildings subjected to ground motions. Setback buildings with mass and stiffness discontinuities are common in modern architecture and quite often they are asymmetric in plan. The proposed analysis provides basic dynamic data (frequencies and peak values of base resultant forces) and furthermore an overview of the building response during a ground excitation. The method is based on the concept of the equivalent single story system, which has been introduced by the author in earlier papers for assessing the response of uniform in height buildings. As basic quantities of the dynamic response of elastic setback buildings can be derived by analyzing simple systems, a structural layout of minimum elastic rotational response can be easily constructed. The behavior of such structural configurations, which is basically translational into the elastic phase, is also examined into the post elastic phase when the strength assignment of the various bents is based on a planar static analysis under a set of lateral forces simulating an equivalent 'seismic loading'. It is demonstrated that the almost concurrent yielding of all resisting elements preserves the translational response, attained at the end of the elastic phase, to the post elastic one.