• Title/Summary/Keyword: ejection

Search Result 708, Processing Time 0.026 seconds

Effects of Thyroid Hormone on Left Ventricular Volume and Function in Hyperthyroidism (갑상선기능항진증(甲狀線機能亢進症)에서 좌심실용적(左心室容積) 및 기능변화(機能變化)에 관한 연구(硏究))

  • Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.2
    • /
    • pp.1-17
    • /
    • 1983
  • The purpose of this study is to investigate the effects of thyroid hormone on the left ventricular(LV) volume arid function in man with untreated hyperthyroidism and to determine the effects of successful therapy for thyrotoxicosis on the ventricular pathophysiology. In the present study, equilibrium radionuclide cardiac angiography was performed and LV volume index, ejection phase indexes of LV performance, serum thyroid hormone levels and other hemodynamic parameters were measured in 28 normal subjects and 39 patients with hyperthyroidism before treatment and again every 4 weeks for the first 2 months after the initiation of effective therapy. The results obtained were as follows; 1) In the untreated hyperthyroid state heart rate, blood volume, cardiac index and stroke volume index($97{\pm}14$ beats/min, $73.5{\pm}11.8ml/kg,\;6.9{\pm}1.4\;l/min/m^2$ and $77.6{\pm}13.8ml/m^2$, respectively) were increased significantly compared to those in normal control($74{\pm}12beats/min$, $66.6{\pm}14.8ml/kg,\;3.8{\pm}1.2\;l/min/m^2$ and $56.6{\pm}13.2ml/m^2$ respectively). $(Mean{\pm}SD)$ 2) There was a significant increase in LV end-diastolic volume index in patients with hyperthyroidism ($30.5{\pm}7.5$ for hyperthyroid group compared to a normal control of $22.2{\pm}6.5$; p<0.001), whereas end-systolic volume index remained unchanged $9.6{\pm}3.6\;and\;8.8{\pm}3.3$ respectively).3) In patients with hyperthyroidism, LV ejection fraction was $70.0{\pm}5.6%$, fractional shortening $32.9{\pm}5.1%$, mean velocity of circumferential fiber shortening(mean Vcf) $1.34{\pm}0.31$ circ/sec and maximum ejection rate $3.47{\pm}0.80$. All the ejection phase indexes were significantly greater than those in normal control($65.2{\pm}5.7%,\;28.8{\pm}3.2%,\;0.88{\pm}0.37$ circ/see and $2.27{\pm}0.50$, respectively; p<0.001). 4) Effective therapy produced significant decrease in all the values of serum thyroid hormone concentrations(p<0.00l), hemodynamic parameters(p<0.001), end-diastolic volume index(p<0.01) and ejection phase indexes of LV contractility in patients with hyperthyroidism and after one to two months, when the patients were euthyroid, these measurements were in the range of normal. 5) A significant linear correlation between mean Vcf and serum thyroxine level(r=0.63, p<0.001) as well as between mean Vcf and serum triiodothyronine level(r=0.62, p<0.001) was found. The lesser degree of correlation was also noted between other ejection phase indexes and serum thyroid hormone concentrations. The results indicate that the major effects of excess thyroid hormone on the LV in human beings with hyperthyroidism are an enhancement of LV function and an increase in LV enddiastolic volume and that these effects cause predictable reversible cardiac alteration which are changed dramatically and immediately after effective therapy.

  • PDF

Effect of Air Ejection on the Behaviors of Sows and their Piglets Related to the Crushing of Piglets by Sows (공기분사가 모돈과 포유자돈의 압사 관련 행동에 미치는 영향)

  • Jeon, J.H.;Yeon, S.C.;Chang, H.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.691-696
    • /
    • 2005
  • Suckling piglets must avoid positions with high air velocity because they don’t have hypodermic fat. Therefore this study examined the effects of air ejection on the behaviors of sows and their piglets. Compressed air was released for 5s at 5s intervals between floor and udder of sows only when they were standing or sitting. Sixteen multiparous crossbred(Landrace×Yorkshire) sows and their piglets were used. Behaviors of sixteen sows and their piglets were recorded for 4 days postpartum, using the LED lamp(wavelength:950nm), CCD camera(Samsung SDC-411), multiplexer(Samsung SDM-080), and time lapsed VCR(Samsung SRV-30). The videotapes were scanned every 30s to obtain an instantaneous behavioral sample. The sow’s standing and sitting rates between control group(CG) and air ejection group(AEG) were not significantly different(P>0.05). This means that air ejection does not affect the behavior of sows. Frequency of the suckling piglets’ behaviors closely related to the crushing by sows was lower in AEG than in CG(P<0.05). These results suggest that air ejection may be available for reduction of the crushing of suckling piglets by sows.

Right Ventricle Ejection Fraction Contributes Severity of Dyspnea in Chronic Obstructive Pulmonary Disease (COPD) (만성폐쇄성폐질환 환자의 호흡곤란 평가에서 우심실 박출계수의 의의)

  • Lee, Jung Eun;Min, Bo Ram;Park, Jae Seok;Park, Hun Pyo;Jun, Mi Jung;Won, Kyung Sook;Choi, Won Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.631-637
    • /
    • 2006
  • Background: Patients with COPD generally complain of very different degrees of dyspnea regardless of their pulmonary function. The study, we assessed the right ventricular ejection fraction in relation to dyspnea in COPD patient. Methods: The pulmonary function including the diffusion capacity was measured. The right ventricle ejection fraction (RVEF) was measured using a first-pass radionuclide scan by multigated acquisition (MUGA). Forty patients with chronic obstructive pulmonary disease (COPD) were stratified for dyspnea according to the Medical Research Council (MRC) scale. Moderate dyspnea and severe dyspnea is defined as MRC 2/3 (n = 16) and MRC 4/5 (n = 24) respectively. Results: The baseline pulmonary function tests including DLCO and the resting arterial blood gas were similar in the moderate and severe dyspnea group, with the exception of the residual volume (% predicted) (moderate $160{\pm}27$, severe $210{\pm}87$, p < 0.03). The right ventricle ejection fraction was significantly (p < 0.001) lower in the severe dyspnea group ($25{\pm}8$) than in the moderate group ($35{\pm}6$). The independent factor assessed by multiple logistic regression revealed only the severity of dyspnea to be significantly associated with RVEF (p < 0.02). Conclusion: This study showed that the right ventricle ejection fraction would contributes to severity of dyspnea in patients with a similar pulmonary function.

A Measurement of Heart Ejection Fraction using Automatic Detection of Left Ventricular Boundary in Digital Angiocardiogram (디지탈 혈관 조영상에서의 좌심실 경계 자동검출을 이용한 심박출 계수의 측정)

  • 구본호;이태수
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.177-188
    • /
    • 1987
  • Detection of left ventricular boundary for the functional analysis of LV(left ventricle) is obtained using automatic boundary detection algorithm based on dynamic program ming method. This scheme reduces the edge searching time and ensures connective edge detection, since it does not require general edge operator, edge thresholding and linking process of other edge detection methods. The left ventricular diastolic volume and systolic volume were computed after this automatic boundary detection, and these volume data were applied to analyze LV ejection fraction.

  • PDF

Introduction to Plastic Injection Molds (사출성형용 금형의 기능 및 구조에 대한 고찰)

  • 허영무
    • Transactions of Materials Processing
    • /
    • v.11 no.8
    • /
    • pp.641-650
    • /
    • 2002
  • For the production of complicated plastic parts in a cycle, a mold is needed.. The basic tasks of a mold are accommodation and distribution of the resin, shaping and cooling the melt and ejection of the molding. To achieve these goal a mold has several important parts and we classified types of molds. The 6 different major functions of a mold are explained and several types of molds are shown in her. I hope these explanation will help to understand injection molds for a design engineer.

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.

Research on the Ejection Gas Generator to Improve Ejecting Performance (사출성능 개선을 위한 사출용 가스발생기 연구)

  • Oh, Seok-Jin;Jang, Seung-Gyo;Cha, Hong-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.5
    • /
    • pp.383-390
    • /
    • 2013
  • The reduction of the maximum acceleration which causes shock for a missile is very important to prevent abnormal operation of a missile and decrease size and cost of missile components. Because the maximum acceleration created by operation of an ejection gas generator occurs in the initial ejection stage, the design parameters which affect initial ejection stage were examined. The igniter and the nozzle closure were selected as design parameters of a gas generator. The maximum acceleration created by the gas generator was examined experimentally by changing of the design parameters. Finally the reduction effect of the maximum acceleration was compared quantitatively by static fire test of a gas generator. The maximum acceleration of the best model which was applied to each optimal design parameter was about 68% reduced than that of the reference model.

Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG (심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.104-109
    • /
    • 2018
  • A non-intrusive ECG and BCG measurement system is introduced. The system is built on a auxiliary backrest of a chair. The developed system is aimed to non-intrusive assessment of cardiovascular dynamic indices such as pulse arrival time(PAT) and pre-ejection period (PEP). In the system, capacitive active electrodes and capacitive grounding were used for the non-intrusive indirect-contact ECG measurement, and EMFi pressure sensor was used for the non-intrusive BCG measurement. The capacitive active electrodes and the EMFi sensor were attached on the backrest. Using the system, ECG and BCG were successfully acquired. The measured BCG showed peaks that following ECG R peaks. It was shown that the time interval between Q wave in ECG and first peak in BCG correlates Pre-ejection period measured by impedance-cardiogram. The results showed that the introduced system can be used for the non-intrusive various cardiovascular information including ECG, PAT, PEP.

Fabrication and Magnetic Properties of Ultrathin Co-based Amorphous Alloy (코발트계 극박형 비정질합금의 형성과 자기적 성질)

  • 노태환
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.255-260
    • /
    • 1998
  • Fabrication condition and magnetic properties of ultrathin Co-based amorphous alloy have been investigated. When the ejection gas pressure was lower than 0.05 kgf/$\textrm{cm}^2$ at the roll speed of 55 m/s, ultrathin ribbons with the thickness less than 10 ${\mu}{\textrm}{m}$ were successfully obtained. The ribbon thickness decreased linearly with the decrease in ejection pressure. Moreover the significant decrease in ribbon width was accompanied with the decrease of thickness in the range of ejection pressure to form an ultrathin ribbon. This behavior was attributed to the decrease of effective ejection pressure in the both end-sides of rectangular nozzle due to the larger friction between molten metal and nozzle wall. The effective permeability at low frequency (1 kHz) decreased largely with the decrease in ribbon thickness, while the coercive force increased with the thickness decrease. It was considered that these behaviors were due to the enhancement of surface effect leading to the suppression of wall motion. However effective permeability at high frequency (1 MHz) increased with the decrease in ribbon thickness, and this was ascribed to the easier magnetization rotation owing to the reduction of eddy current.

  • PDF

Effect of Heat Transfer and Phase Change of Coolant on the Performance of Mixed-gas Ejection System (냉각제의 분사조건 및 상변화가 혼합가스 사출시스템의 성능에 미치는 영향)

  • Kim, Hyun Muk;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.84-93
    • /
    • 2018
  • Three-dimensional (3D) numerical simulations have been carried out to study how coolant injection conditions influence the cooling efficiency and projectile ejection performance in a mixture-gas ejection system (or gas-steam launch system). The 3D single-phase computational model was verified using a 1D model constructed with reference to the previous research and then a two-phase flow computation simulating coolant injection on to hot gas was performed using a DPM (Discrete Phase Model). As a result of varying the coolant flow rate and number of injection holes, cooling efficiency was improved when the number of injection holes were increased. In addition, the change of the coalescence frequency and spatial distribution of coolant droplets caused by the injection condition variation resulted in a change of the droplet diameter, affecting the evaporation rate of coolant. The evaporation was found to be a critical factor in the design optimization of the ejection system by suppressing the pressure drop while the temperature decreases inside the breech.