• 제목/요약/키워드: effluent

검색결과 1,975건 처리시간 0.026초

경기지역 산업시설 방류수 생태독성 영향 평가 (Ecotoxicity Assessment of Industrial Effluent in Gyeonggi-do)

  • 조원실;김상훈;양형재
    • 한국환경보건학회지
    • /
    • 제37권2호
    • /
    • pp.113-123
    • /
    • 2011
  • Objectives: Industrial development in Korea results in a rapid increase in the number of chemicals, some of which may be responsible for toxicity to aquatic ecosystems. In addition, the types of hazardous chemicals included in industrial effluents have gradually increased. Therefore, chemical analysis alone is not enough to assess ecological effects of toxic chemicals in wastewater. Methods: In response to new regulations as whole effluent toxicity (WET) tests for effluent discharge of 15 publicly owned treatment works (POTWs) and 25 industrial effluent treatment plants in Gyeonggi-do, which will be effective from 2011, a necessity of studies emerges that investigates toxicity levels. Results: In case of the public treatment plants, none of them had exceeded the criteria for ecotoxicity. As for individual wastewater discharge facilities, on the other hand, two types were found to exceed the criteria: pulp and paper manufacturing facilities and pharmaceutical manufacturing facilities. For the pulp and paper manufacturing facilities, monitoring results could not help determine the exact toxicant identification. However, Daphnia magna inhibition effect or death was found to leave white plums, suggesting that suspended solids treated and the polymer used in coagulant dose. In case of pharmaceutical manufacturing facilities, the general water quality parameters cannot affect Daphia magna. However, conductivity and salinity can have an effect to be 14,000 ${\mu}s/cm$, 8.1‰ by salts, respectively. Toxicity Identification Evaluation (TIE) and Toxicity Reduction Evaluation (TRE) procedures results appeared to be effective for identifying toxic compounds in $Cl^{-}$ and $SO_4^{2-}$. Conclusions: It is necessary to develop control measures for water treatment chemicals and salts used for processes such as coagulation in individual wastewater discharge facilities in order to achieve the goal to protect aquatic ecosystems in public waters.

간접방류사업장 관련 폐수의 생태독성수준 및 특성 평가 (Evaluation of Ecotoxicity and Characteristics on Indirect Effluents and Related Wastewater)

  • 김종민;신기식;이수형;이정서;이택준
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.481-486
    • /
    • 2017
  • This paper aims to evaluate the characteristics of direct and indirect effluents'toxicity level and difference between two test durations (24 h and 48 h) of test method. The proportion of the indirect effluent samples which exceeded the ecotoxicity permit limitations (TU 1 or TU 2) showed more than 2 times higher than that of direct effluent samples. However, effluent toxicity of Wastewater Treatment Plants (WTPs) indicated less than TU 1 regardless of influent toxicity. From this results, treatment process was thought to have a good efficiency. WTP Salinity was very similar between influent and effluent. This trend could be reconfirmed by the component ratio of ion concentration between them and $Na^+$, $SO_4^{2-}$, $C^-$ lions which have a greater percentage than other ions. In addition, in case of high salinity, toxicity value also showed high level. To judge from above results, indirect effluents which were exempted from application of ecotoxicity standards, may need a new effluent limitations regardless of the treatment efficiency of WTP. According to circumstances, effective countermeasure may need to restrain the discharge of salinity-contained effluents which came from indirect-effluent factories. Test duration comparative study indicated that 48 h results were higher toxicity (exceeding rate of ecotoxicity criteria) than 24 h by the 5 to 5.4 percentage. 24 h test duration seemed to be useful in case of rapid detection, whereas 48 h test method could be applied for reinforcement of ecotoxicity regulatory system.

DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구 (Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System)

  • 이병호;김상희
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

물 재이용을 위한 하수처리장 방류수 색도의 자외선처리에 미치는 과산화수소의 영향 (Effect of Hydrogen Peroxide on UV Treatment of Color in Secondary Effluent for Reclamation)

  • 박기영;맹승규;김기팔;이석헌;권지향;안규홍
    • 상하수도학회지
    • /
    • 제18권3호
    • /
    • pp.377-384
    • /
    • 2004
  • In the present study, a feasibility of an advanced oxidation process using UV/Hydrogen peroxide($H_2O_2$) system equipped with a medium pressure lamp for secondary effluent reclamation was investigated. Initial concentration of $H_2O_2$ and pH were changed to determine the optimum operation condition for the system. The removal efficiency of color was than 80% with 14.3mg/L of initial $H_2O_2$ and 5 minute of contact time in the UV/$H_2O_2$ system. The color removal was analyzed using first-order reaction equation. The dependence of rate constant (k) on initial $H_2O_2$ represented the rational relationship with maximum value. Residual $H_2O_2$ caused increase of effluent COD, since analyzing agent, dichromate, reacted with $H_2O_2$ in the sample. Therefore, excess initial concentration of $H_2O_2$ would significantly affect effluent COD measurement. At pH variation experiment, both residual $H_2O_2$ and color showed peak in the neutral pH range with the same pattern. Effect of $H_2O_2$ dose also enhanced color removal but raised residual $H_2O_2$ problem in the continuous operation UV system. In conclusion, these results indicated that medium pressure UV/$H_2O_2$ system could be used to control color in the secondary effluent for reclamation and reuse.

통계기법을 이용한 공공하수처리시설의 운영실태 평가방법 연구 (A Study on the Evaluation for Operations of Public Sewage Treatment Plants Using Statistics Technique)

  • 최인철;안태웅;유순주;정현미;권오상;김원기;염익태;손대희
    • 한국물환경학회지
    • /
    • 제30권5호
    • /
    • pp.524-531
    • /
    • 2014
  • Korea has been trying to manage water quality of rivers and lakes in many ways. Ministry of Environment is making continuous efforts of operation control improvement such as strengthening effluent standards in sewage treatment plants and expanding Tele-Monitoring System (TMS). However, evaluation method for operations of sewage treatment plants and establishment system of effluent standards are inadequate. The objective of this study is to evaluate for operations of sewage treatment plants using statistics technique such as frequency analysis, percentile, normal distribution analysis. We used the effluent data (BOD, COD, SS) collected at 299 plants in 2012. The values were very low by comparison with standards. The Data followed a normal distribution. We think that distribution characteristics are closely related with effluent standards, especially T-P and BOD. Statistics technique attempted in this study can be used to evaluate for operations of sewage treatment plants and assess the appropriateness of effluent standards based on TBEL(Technology-based effluent limitation). And, this technique can be used to figure out the overall level of plants, the status of each plant and the favorable treatment process for each item (BOD, COD etc.). Data acquired through this method can be used to improve facilities and operation techniques and decide on a sewerage policy.

입자추적 실험을 이용한 새만금 배수갑문 유출수의 영향 범위 연구 (A Study on the Influence of the Saemangeum Sluice-Gates Effluent Discharge using the Particle Tracking Model)

  • 조창우;송용식;방기영
    • 한국해안·해양공학회논문집
    • /
    • 제32권4호
    • /
    • pp.211-222
    • /
    • 2020
  • 입자추적 실험 결과를 이용하여 새만금 배수갑문 유출수의 영향 범위 파악을 위한 방법론을 수립하고, 2017년을 대상으로 새만금 배수갑문 유출수의 영향 범위를 계절별 확률 분포로 제시하였다. 물질 수송 시간의 지표 중 하나인 water age를 계산하고 입자추적 실험 결과와 비교하여 계산 결과의 타당성을 입증하였다. 배수갑문 유출수는 신시 또는 가력 배수갑문을 중심으로 그 영향 범위가 방사형으로 증가하는데 계절풍의 영향으로 동계에는 남측으로, 하계에는 북측으로 영향 범위가 치우치는 것으로 예측되었다. 예측 결과는 2017년 상황에 한정되지만, 본 연구에서 수립한 입자추적 실험을 이용한 배수갑문 유출수 영향 범위 산정 기법은 현재 변화하고 있는 새만금 해역의 장래 배수갑문 유출수의 영향 범위 산정 연구에 활용이 가능하다.

복합생물막 반응기를 이용한 하수처리시 탈질화 특성 (Characteristics of Denitrification from Municipal Wastewater Treatment using a Combined Fixed Film Reactor (CFFR) Process)

  • 이종현;남해욱;김영규;박태주
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.107-113
    • /
    • 1999
  • A new biological nutrient removal system combining $A^2/O$ process with fixed film was developed in this work and the characteristics of denitrification were especially investigated in the combined fixed film reactor(CFFR). Media was added in the anaerobic, anoxic and aerobic reactors, respectively. Tests were made to establish the effluent level of $NO_x-N$, COD, DO and nitrite effects on $NO_x-N$ removal in the CFFR by decreasing hydraulic retention time (HRT) from 10.0 to 3.5 hours and by increasing internal recycle ratio form 0% to 200%. The influent was synthesized to levels similar to the average influent of municipal wastewater treatment plants in Korea. SARAN media with a porosity of 96.3% was packed 40% / 130% / 25% based on its reactor volume, respectively. It was found that COD rarely limited dentrification in the anoxic reactor because of high $C/NO_x/-N$ ratio in the anoxic reactor, while DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent inhibited denitrification in the anoxic reactor. It was proved that the critical points of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent were 0.15mg/L and 10%, respectively. As the internal recycle ratio increased, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent increased. Especially, at the condition of internal recycle ratio, 200%, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent exceeded the critical points of 0.15mg/L and 10%, respectively. Then, denitrification efficiency considerably decreased. Consequently, it was represented that the control of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent can assure effective denitrification.

  • PDF

정수장 슬러지 농축조 배출수의 망간 농도에 미치는 pH의 영향 (Influence of pH on Mn Concentration of Effluent from Sludge Thickener of Water Treatment Plant)

  • 김연정;이승은;백승철;김태희
    • 한국지반환경공학회 논문집
    • /
    • 제16권5호
    • /
    • pp.27-33
    • /
    • 2015
  • 정수공정 중에 응집된 망간은 슬러지 농축조에 체류하는 동안 재용출 되어 배출수의 망간 허용기준치를 초과하는 문제가 발생되고 있다. 본 연구에서는 정수공정 중에 슬러지 농축조 배출수의 pH를 조정함으로써 망간 농도에 미치는 pH의 영향에 대하여 연구하였다. 초기 pH 6.1에서는 응집된 슬러지로부터 망간이 재용출 되어 청정지역 배출 기준인 2mg/L를 초과하였으나 NaOH, KOH, CaO, $Ca(OH)_2$, $CaCO_3$ 등 알칼리 물질을 이용하여 pH를 상승시켰을 경우 망간 농도를 청정지역 배출 기준 이하로 낮출 수 있었다. 또한 알칼리성 물질로서 석회석 광산에서 선별과정 중 발생하는 폐석회석을 이용하여 정수장 슬러지의 망간 재용출을 억제할 수 있는 가능성을 확인하였다.

발전소 온배수에 의한 해양물리학적 평가기법 개선방안 연구 (Improvement Plan of Ocean Physics Assessment Technique for Power Plant Thermal Effluent)

  • 김명원;조광우;맹준호;강태순;김종규
    • 한국해양공학회지
    • /
    • 제28권3호
    • /
    • pp.245-253
    • /
    • 2014
  • This research analyzed the current situation and problems with an environmental impact assessment to provide a rational ocean physics assessment technique for power plant thermal effluent. This research also tried to create an improvement plan for heated effluent diffusion impact assessment by examining the reporting regulations for environmental impact assessment, national and international evaluation guidelines, etc. In the case of evaluating the oceanographic impact of heated effluent discharged from power plants, a pre-investigation is necessary before a full-scale presentence investigation, to accurately predict and minimize power plant construction effects on the surrounding environments. Before this presentence investigation, moreover, an integrated presentence plan, which agrees with the business plan, effect prediction, and post-investigation, needs to be established. A sufficient summit investigation must be made, which considers climate changes, and new and additional power plant construction. For accurate long-term oceanic environmental change prediction, the credibility of effect prediction must be elevated by presenting an evaluation method that is categorized by numerical organization models, verification methods, result presentation, and other things. Furthermore, unproductive conflicts between the people involved in heated effluent evaluation should be reduced by these improvement plans.

2차처리장 방류수 정화 부들습지셀의 초기운영단계 질산성질소 제거 (Nitrate Removal of a Cattail Wetland Cell Purifying Effluent from a Secondary-Level Treatment Plant During Its Initial Operating Stage)

  • 양홍모
    • 한국환경농학회지
    • /
    • 제23권4호
    • /
    • pp.228-233
    • /
    • 2004
  • Nitrate removal was examined from May to October 2003 of a surface flow treatment wetland cell, which was a part of a treatment wetland system composed of four wetland cells and a distribution pond The system was established on rice paddy near the Kohung Estuarine Lake located in the southern part of the Korean Peninsula. Effluent from a secondary-level night soil treatment plant was funneled into the system. The investigated cell, 87 m in length and 14 m in width, was created in April 2003. An open water was designed at its center, which was equivalent to 10 percent of its total area. Cattails (Typha angustifolia) were transplanted from natural wetlands into the cell and their stems were cut at about 40cm height from their bottom ends. Average $25.0\;m^3/day$ of effluent from the treatment plant was funneled into the cell by gravity flow and average $24.1\;m^3/day$ of its treated effluent was discharged into the Sinyang Stream flowing into the lake. Its water depth was maintained about 0.2 m and its hydraulic detention time averaged 5.2 days. Average height of the cattail stems was 42.5 cm in May 2M3 and 117.7 cm in September 2003. The number of stems averaged $9.5\;stems/m^2$ in May 2003 and $16.4\;stems/m^2$ in September 2003. The growth of cattails was good. Temperature of influent and effluent averaged 25.9 and $26.7^{\circ}C$, respectively. $NO_3$-N loading rate of influent and effluent averaged 176.67 and $88.09\;mg/m^2\;day$, respectively. Removal of rf03-N averaged $89.58\;mg/m^2\;day$ and its removal rate by mass was about 50%. Considering its initial operating stage in which cattail rhizomes and litter layer on the bottom were not Idly established, the $NO_3$-N removal rate of the cell was rather good.