• 제목/요약/키워드: effectiveness factor

검색결과 1,657건 처리시간 0.294초

Reducing of Authentication Signaling Traffic in LTE Networks (LTE 네트워크에서 인증 시그널링의 감소 기법)

  • Kim, Seonho;Jeong, Jongpil
    • KIPS Transactions on Computer and Communication Systems
    • /
    • 제1권2호
    • /
    • pp.109-118
    • /
    • 2012
  • As a result of the prevalence of smartphone, various mobile services became faster by LTE networks. Because many mobile devices are used more wireless services, heavy signaling traffic for authentication could be generated. Authentication is an important factor in wireless networks to identify devices; it is the start of wireless networks. This paper analyzes previous patterns for more effective authentication in accessing of another external networks. We propose a fast authentication scheme for minimizing of signaling cost between the authentication server and external networks. And we calculate the rate of authentication occurrence in LTE networks using mathematical modeling as well as the change of signaling cost for authentication in various network environments. Finally, we calculate the optimized number of authentication data and show the effectiveness for authentication signaling costs.

Electric lighting energy saving through the use of a Fresnel lens based fiber-optic solar lighting system : Simulation and measurements (광화이버 및 Fresnel lens 적용 집광식 자연채광 시스템의 이용을 통한 조명에너지의 절감 : 시뮬레이션 및 실측 비교)

  • Jeong, Haejun;Kim, Wonsik;Kim, Yeongmin;Han, Hyun Joo;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • 제26권1호
    • /
    • pp.34-44
    • /
    • 2017
  • This paper deals with the effectiveness of a fiber optic solar lighting system that uses a Fresnel lens mounted on a two-axis solar tracker. A series of comparative analyses were made concerning its performance as compared to fluorescent lighting by using a simulation model based on ECOTECT and RADIANCE as well as referring to actual data. ECOTECT was used to model the test room (space) while RADIANCE was used for its indoor lighting conditions (environment). It was found that the average indoor light levels of fluorescent lighting fully satisfy the KS standard (KS A 3011, general office, class [G]: 300-400-600lux) whereas those of the solar lighting with light diffusers depends on the occlusion factor of roller shades installed on the south window.

454 Pyrosequencing Analysis of Bacterial Diversity Revealed by a Comparative Study of Soils from Mining Subsidence and Reclamation Areas

  • Li, Yuanyuan;Chen, Longqian;Wen, Hongyu;Zhou, Tianjian;Zhang, Ting;Gao, Xiali
    • Journal of Microbiology and Biotechnology
    • /
    • 제24권3호
    • /
    • pp.313-323
    • /
    • 2014
  • Significant alteration in the microbial community can occur across reclamation areas suffering subsidence from mining. A reclamation site undergoing fertilization practices and an adjacent coal-excavated subsidence site (sites A and B, respectively) were examined to characterize the bacterial diversity using 454 high-throughput 16S rDNA sequencing. The dominant taxonomic groups in both the sites were Proteobacteria, Acidobacteria, Bacteroidetes, Betaproteobacteria, Actinobacteria, Gammaproteobacteria, Alphaproteobacteria, Deltaproteobacteria, Chloroflexi, and Firmicutes. However, the bacterial communities' abundance, diversity, and composition differed significantly between the sites. Site A presented higher bacterial diversity and more complex community structures than site B. The majority of sequences related to Proteobacteria, Gemmatimonadetes, Chloroflexi, Nitrospirae, Firmicutes, Betaproteobacteria, Deltaproteobacteria, and Anaerolineae were from site A; whereas those related to Actinobacteria, Planctomycetes, Bacteroidetes, Verrucomicrobia, Gammaproteobacteria, Nitriliruptoria, Alphaproteobacteria, and Phycisphaerae originated from site B. The distribution of some bacterial groups and subgroups in the two sites correlated with soil properties and vegetation due to reclamation practice. Site A exhibited enriched bacterial community, soil organic matter (SOM), and total nitrogen (TN), suggesting the presence of relatively diverse microorganisms. SOM and TN were important factors shaping the underlying microbial communities. Furthermore, the specific plant functional group (legumes) was also an important factor influencing soil microbial community composition. Thus, the effectiveness of 454 pyrosequencing in analyzing soil bacterial diversity was validated and an association between land ecological system restoration, mostly mediated by microbial communities, and an improvement in soil properties in coal-mining reclamation areas was suggested.

Effects of Feeder Cells on the Primary Culture of Ovarian Cell Populations from Adult Japanese Medaka (Oryzias latipes)

  • Ryu, Jun Hyung;Gong, Seung Pyo
    • Journal of Animal Reproduction and Biotechnology
    • /
    • 제35권1호
    • /
    • pp.65-72
    • /
    • 2020
  • Fish ovarian germline stem cells (OGSCs) that have the abilities to self-renew and differentiate into functional gametes can be used in various researches and applications. A main issue to be solved for effective utilization of fish OGSCs is the development of their stable in vitro culture condition, but only few researches about fish OGSC culture have been reported so far. In this study, in order to find the clues to develop the culture condition for OGSCs from Japanese medaka (Oryzias latipes), we tried to establish somatic cell lines as a candidate for the feeder cells and evaluated its supporting effects on the culture of ovarian cell populations from O. latipes. As the results, the somatic cell lines could be established only from the embryonic tissues among three tissues derived from embryos, fins and ovaries. Three embryonic cell lines were tested as a feeder cell for the culture of ovarian cell population and all three cell lines induced cell aggregation formation of the cultured ovarian cells whereas the feeder-free condition did not. Furthermore, a significant cellular proliferation was observed in the ovarian cells cultured on two of three cell lines. As a trial to increase the capacity of the cell lines as a feeder cell that supports the proliferation of the cultured ovarian cells, we subsequently established a stable line that expresses the foreign O. latipes fibroblast growth factor 2 (FGF2) from an embryonic cell line and evaluated its effectiveness as a feeder cell. The ovarian cells cultured on FGF2 expressing feeder cells still formed cell aggregates but did not show a significant increase in cellular proliferation compared to those cultured on non-transformed feeder cells. The results from this study will provide the fundamental information for in vitro culture of medaka OGSCs.

Factors influencing the organizational citizenship behaviors in clinical dental hygienists (임상치과위생사의 조직시민행동에 영향 요인)

  • Min, Hee-Hong;Yun, Mi-Hae;Ahn, Kwon-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • 제18권2호
    • /
    • pp.165-175
    • /
    • 2018
  • Objectives: This study aims to examine the factors that influence the organizational citizenship behavior of clinical dental hygienists to use them as basic data for improving effectiveness and efficiency of dental clinics and hospitals. Methods: A self-reported questionnaire was answered by 250 clinical dental hygienists in Seoul, Gyeonggi, Chungcheong, Jeolla and Gyeongsang province areas who were chosen using convenient sampling method from May 1st to June 30th of 2017. The data was analyzed using IBM SPSS/WIN 22.0 factor analysis on clinical dental hygienists' organization citizenship behavior, organizational commitment, empowerment, self-leadership and job satisfaction. T-test and one-way ANOVA were performed for subjects' general characteristics and organizational citizenship behavior, organizational commitment, empowerment, self-leadership and job satisfaction depending on their job characteristics. The mean comparison was drawn using the Scheffe test. Pearson's correlation and multiple regression analysis were performed to examine the relation of clinical dental hygienists' organizational citizenship behavior, organizational commitment, empowerment, self-leadership and job satisfaction Also, the significance level was set at 0.05. Results: Clinical dental hygienists' organizational citizenship behavior was 3.84 points with organizational commitment of 3.27, empowerment of 3.41, self-leadership 3.45 and job satisfaction of 3.57. Factors that influence clinical dental hygienists' organizational citizenship behavior appeared in the order of organizational commitment, job satisfaction, self-leadership, empowerment and job intensity, and the model's explanation power was 45.6%. Conclusions: Clinical dental hygienists' organizational citizenship behavior was correlated to career, organizational commitment, empowerment, self-leadership and job satisfaction, where organizational commitment had the biggest influence. Therefore, clinical dental hygienists organizational citizenship behavior needs further studies and investigtae more ways to promote factors that influence organizational citizenship behavior.

A Study on the Application of Safety Design based on the Risk of Construction Process (건설공정 위험성 기반 설계안전성 활용 방안 연구)

  • Lee, Hyeon-Sung
    • Journal of the Society of Disaster Information
    • /
    • 제15권4호
    • /
    • pp.493-501
    • /
    • 2019
  • Purpose: The purpose of this study is to prevent construction safety accidents, and the design safety systems were reviewed. This paper aims to establish as an effective system by looking at the implementation procedures and contents of the design safety review system. Method: We reviewed the purpose and content of the law, accident statistics, etc. for the study. In addition, we looked at the implementation plans for actual construction sites using the 'design safety' assessment process as defined by the Act. Results: We divided it into the data review phase, the risk factor elicitation and alternative setup phase, and the design safety assessment report preparation stage. Conclusion: it is necessary to derive risk factors that take into account the diversity of construction sites. However, the effectiveness of other reports is questioned as they are often copied and written. Therefore, it is necessary to strengthen external verification procedures attended by construction safety experts.

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.

A Novel Utility AC Frequency to High Frequency AC Power Converter with Boosted Half-Bridge Single Stage Circuit Arrangement

  • Saha, Bishwajit;Kwon, Soon-Kurl;Koh, Hee-Seog;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2006
  • This paper presents a novel soft-switching PWM utility frequency AC to high frequency AC power conversion circuit Incorporating boost-half-bridge inverter topology, which is more suitable and acceptable for cost effective consumer induction heating applications. The operating principle and the operation modes are presented using the switching mode and the operating voltage and current waveforms. The performances of this high-frequency inverter using the latest IGBTs are illustrated, which includes high frequency power regulation and actual efficiency characteristics based on zero voltage soft switching (ZVS) operation ranges and the power dissipation as compared with those of the previously developed high-frequency inverter. In addition, a dual mode control scheme of this high frequency inverter based on asymmetrical pulse width modulation (PWM) and pulse density modulation (PDM) control scheme is discussed in this paper in order to extend the soft switching operation ranges and to improve the power conversion efficiency at the low power settings. The power converter practical effectiveness is substantially proved based on experimental results from practical design example.

  • PDF

Modeling and Analysis of Variable Wind Speed Turbine System Using Back to Back Converter (Back to bock 컨버터를 갖는 가변속 풍력터빈 시스템의 모델링과 해석)

  • Kim, Eel-Hwan;Kang, Keong-Bo;Kim, Jae-Hong;Moon, Sang-Ho;Oh, Sung-Bo;Kim, Se-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제19권8호
    • /
    • pp.150-157
    • /
    • 2005
  • This paper presents the simulation modeling and analysis of variable wind speed turbine system(VWTS) using the doubly fed induction generator(DFIG) connected the back to back converter system in the rotor side. In the simulation, using the model system which has the 660[kW] rated power, blade control and the dual converter system are modeled for verifying the control characteristics. The VWTS is controlled by the optimal pitch angle for maximum output power under the rated wind speed, and for the rated output power over the rated wind speed. And also power factor is controlled by the reactive power. To verify the effectiveness of the proposed method, simulation results are compared with the actual data from the V47 VWTS located in Hangwon wind farm in Jeju-Do. According to the comparison of these results, this method shows excellent performance.

A Effect of Unreliable Default Parameter in Forecasting Delay and Level of Service of Signalized Intersection (초기변수의 불확실성이 신호교차로 지체모형 및 서비스수준 예측에 미치는 영향 분석)

  • Kim, Sung-Deuk;Park, Won-Kyu;Kim, Kyung-Kyu
    • Journal of Navigation and Port Research
    • /
    • 제27권4호
    • /
    • pp.471-478
    • /
    • 2003
  • In the Signalized Intersection, the capacity analysis is conducted with a large amount of input data such as road way, traffic and signal condition. but the level of service(LOS) is determined by delay estimated as a measure of effectiveness (MOE) based on this procedure. However, It is under the circumstances which are not considered for the errors caused by the uncertainty of input data in the field(the turing volumes, lane geometry, signal timing, grade of approach lane, percentage heavy vehicles, peak hour factor and arrival type etc.) as become the bases in the determination of the capacity and LOS. It includes the problem of reliability which is not verified for the capacity and LOS estimated. So, this study is to suggest the minimization of their influences by examining whether the uncertainty of input data such as the traffic volume, percentage of heavy vehicles and roadway geometry on the approach lane in the intersection under the study affects the capacity analysis and LOS determination.