• 제목/요약/키워드: effective dose

검색결과 2,494건 처리시간 0.028초

Selection of Effective Herbal Medicines for Parkinson's Disease Based on the Text Mining of the Classical Korean Medical Literature Donguibogam

  • Bae, Hyo Won;Lee, Tae Wook;Choi, Byung Tae;Shin, Hwa Kyoung;Yun, Young Ju
    • 대한한의학회지
    • /
    • 제42권4호
    • /
    • pp.120-132
    • /
    • 2021
  • Objectives: The prevalence of Parkinson's disease is on an upward trend along with an increase in the aging population but there is no available treatment that halts the progression of neurodegeneration. This study reports a numerical analysis on Donguibogam and suggests novel herbal drugs, which have never been researched before but found to be deemed effective in this study. Methods: Referring to 71 Korean medicine symptom terms that represent the symptoms of Parkinson's disease, 4170 prescriptions described in Donguibogam were classified into two groups based on whether their main effects were effective for Parkinson's disease or not. Comparing the two groups, the chi-square test was performed to select statistically significant herbs, while the t-test, Wilcoxon test, and descriptive statistics were performed to determine the appropriate dose. Results: One hundred and twenty-seven prescriptions effective for Parkinson's disease were identified. The chi-square test determined 17 herbs that are effective for symptomatic treatment. Among the medicinal herbs, the authors suggest Osterici seu Notopterygii Radix et Rhizoma, Ephedrae Herba, Aconiti Tuber, Myrrha, Sinomeni Caulis et Rhizoma, and Aconiti Kusnezoffii Tuber as herbal candidates that have never been studied for Parkinson's disease. Through the statistical tests, it was judged that the mean value of the dose of the entire prescription was the appropriate dose for each herb. Conclusions: Seventeen herbs were selected for Parkinson's disease and the appropriate daily dose were calculated. Furthermore, this study presented a new process that applies a statistical method to traditional medical literature and preselecting herbs deemed effective for specific diseases.

Assessment of Internal Dose by $^3H\;&\;^{14}C$ of Total Diet for Inhabitants near Wolsung Nuclear Power Plants

  • Park, G.;Lin, X.J.;Kim, W.;Kang, H.D.;Doh, S.H.;Kim, D.S.;Kim, C.K.
    • Journal of Radiation Protection and Research
    • /
    • 제28권1호
    • /
    • pp.51-57
    • /
    • 2003
  • To assess the internal dose by $^3H\;&\;^{14}C$ in total diet of inhabitants near Wolsung Nuclear Power Plants, TFWT, OBT and $^{14}C$ concentration in total diet was analyzed for collection region and time. TFWT, OBT and $^{14}C$ concentrations were in the range of 3.19-42.2 Bq/L, 1.00-39.4 Bq/L, and 0.230-0.855 Bq/gC, respectively. The calculated annual effective dose with TFWT, OBT and $^{14}C$ is $6.10{\times}10^{-5}mSv/y,\;3.71{\times}10^{-5}mSv/y\;and\;7.08{\times}10^{-3}mSv/y$, respectively. And then annual internal dose with total diet for inhabitants near Wolsung NPPs is about $7.18{\times}10^{-3}mSv/y$, which is about 0.72% of annual effective dose limit 1 mSv/y.

Cancer Risk Assessment Due to Natural and Fallout Activity in Some Cities of Pakistan

  • Ahad A.;Matiullah Matiullah;Bhatti Ijaz A.;Orfi S.D.
    • Journal of Radiation Protection and Research
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2006
  • The measured mean activities of $^{226}Ra,\;^{232}Th,\;^{40}K\;and\;^{137}Cs$ in the soil of Bahawalpur, Bahawalnagar and Rahimyar Khan Bistricts were 32.9, 53.6, 647.4 and 1.8 Bq $kg^{-1}$. The average absorbed dose rate calculated from these activities was 74.3 nGy $h^{-1}$ and the mean annual effective dose rate was found to be 0.46 mSv $y^{-1}$. Absorbed doses to different body organs were derived from annual effective doses using tissue weighting factors. Radiation induced fatal cancer risks were assessed by using ICRP 60 Model. Estimations incurred 184deaths per year due to cancer.

체외충격파쇄석술에서 투시 시 주요 장기별 방사선 피폭선량 (Radiation Dose during Fluoroscopy at the Organ from Extracorporeal Shock Wave Lithotripsy)

  • 문성호;정홍량;임청환
    • 한국콘텐츠학회논문지
    • /
    • 제10권5호
    • /
    • pp.343-350
    • /
    • 2010
  • 체외충격파쇄석술(Extracorporeal shock wave lithotripsy ; ESWL) 시 환자가 받는 방사선 피폭선량을 측정하기 위하여 신장 및 요관 결석으로 진단을 받은 총 55명(남:36명, 여:19명)을 대상으로 방사선피폭선량을 측정하였다. 측정 방법은 투시 관전압 80kVp, 관전류 5mA로 고정하여 인체 모형의 Rando Phantom과 형광유리 선량계를 사용하였으며, 주요 장기인 양측 신장, 방광, 간에 5분과 10분씩 각각 2회 흡수선량을 측정하여 유효선량으로 환산하였다. 환자 당 평균 시행 횟수는 1.8회(1~4)이었고, 평균 투시시간은 533초(248~2516)로 나타났다. 우측 신장결석 치료 시 우측 신장의 평균값은 2.458mSv, 좌측 신장은 0.152mSv, 간은 1.404mSv, 방광은 0.019mSv로 측정 되었고, 좌측 신장결석 치료 시 좌측 신장의 평균값은 2.496mSv, 우측 신장은 0.252mSv, 간은 0.178mSv, 방광은 0.017mSv이었으며, 하부요관 결석치료 시 방광에서의 평균값은 3.742mSv, 우측 신장은 0.009mSv, 좌측 신장은 0.01mSv로 유효선량이 측정 되었다.

유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교 (Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry)

  • 박태석;한준희;조승연;이은임;조규원;권대철
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

치과 임프란트 치료 계획을 위한 나선형 일반 단층촬영과 전산화 단층촬영시 흡수선량 및 유효선량 평가 (Absorbed and effective dose from spiral and computed tomography for the dental implant planning)

  • 홍병희;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제31권3호
    • /
    • pp.165-173
    • /
    • 2001
  • Objectives : To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. Materials and Methods: For radiographic projection, TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophagus. Effective dose was calculated, using the method suggested by Frederiksen et al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. Results: The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Conclusions: Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  • PDF

담배연기와 담뱃잎 내 함유된 방사능 농도분석 및 위해도 평가 (Analysis of Radioactivity Concentrations in Cigarette Smoke and Tobacco Risk Assessment)

  • 이세령;이상복;김정윤;김지민;방예진;이두석;조형준;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.489-494
    • /
    • 2021
  • In this study, radioactivity quantitative analysis was performed on radon contained in cigarette, and the effective dose was calculated using the result value to determine the amount of exposure caused by smoking. A total of 5 types of cigarettes were sampled. Cigarette smoke was collected by using activated carbon, and tobacco were measured by homogenizing for quantitative analysis. For each sample, Bi-214 and Pb-214 were subjected to gamma nuclide analysis to observe the uranium-based radioactive material contained in cigarette, and a measurement time of 30,000 seconds was set for the sample based on the results of previous studies. As a result of measuring the radioactivity of tobacco, a maximum of 0.715 Bq/kg was derived, and in the case of cigarette smoke measured using activated carbon, a maximum of 3.652 Bq/kg was derived. Using this measurement, the average effective dose to the lungs is 0.938 mSv/y, and it was found that there is a possibility of receiving exposure up to 1.099 mSv/y depending on the type of tobacco. It was found that the exposure dose due to cigarette occupies a large proportion of the annual effective dose limit for the general public. Therefore, more diverse studies on radioactive substances in cigarette are needed, and measures to monitor and reduce the incidental exposure to radon should be established.

복부직경에 따른 CT유효선량 및 화질변화 비교 분석 (A Comparison Analysis of CT Effective Dose and Image Quality according to Abdominal Diameter)

  • 윤준;김현주
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.821-826
    • /
    • 2018
  • 본 연구는 경기도 소재 대학병원에 2018년 1월1일부터 2018년 6월30일까지 복부 CT검사를 위해 내원한 모든 환자의 영상 중 무작위로 선정하여 복부 면적의 크기 별로 20명 씩 60명을 총 3군으로 분류하여 복부 CT영상의 면적에 따른 유효선량과 화질의 변화정도를 알아보았다. 그 결과 평균면적 군 에서 유효선량이 7.34 mSv로, 평균면적이상 군은 8.39 mSv, 평균면적이하 군은 5.89 mSv로 측정 되었다. 화질분석을 위해 복부면적에 따라 동일한 3영역에 ROI를 그려 비교해본 결과 3군으로 분류한 복부면적에서 모두 CT value가 유의한 차이가 있는 것으로 분석되었다(p<0.05). 향후 실제 임상에서 적용할 수 있는 프로토콜을 개발 시 본 연구결과를 기초자료로 활용할 수 있을 것으로 사료되며 현재 임상에서 CT검사 시 적용하고 있는 다양한 선량감소 프로그램을 적용 및 복부 면적 외 다양한 환자의 변환 조건 등을 고려하여 연구와 고찰을 도출한다면 화질과 피폭선량 감소에 도움을 줄 수 있을 것으로 사료된다.

Estimation of long-term effective doses for residents in the regions of Japan following Fukushima accident

  • Kim, Sora;Min, Byung-Il;Park, Kihyun;Yang, Byung-Mo;Kim, Jiyoon;Suh, Kyung-Suk
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.837-842
    • /
    • 2019
  • A large amount of radioactive material was released from the Fukushima Daiichi Nuclear Power Plant (FDNPP) in 2011 and dispersed into the environment. Though seven years have passed since the Fukushima Daiichi Nuclear Power Plant accident, some parts of Japan are still under the influence of radionuclide contamination, especially Fukushima Prefecture and prefectures neighboring Fukushima Prefecture. The long-term effective doses and the contributions of each exposure pathway (5 exposure pathways) and radionuclide ($^{131}I$, $^{134}Cs$, and $^{137}Cs$) were evaluated for people living in the regions of Fukushima and neighboring prefectures in Japan using a developed dose assessment code system with Japanese specific input data. The results estimated in this study were compared with data from previously published reports. Groundshine and ingestion were predicted to contribute most significantly to the total long-term dose for all regions. The contributions of each exposure pathway and radionuclide show different patterns for certain regions of Japan.

Determination of dosimetric dependence for effective atomic number of LDR brachytherapy seed capsule by Monte Carlo simulation

  • Berkay Camgoz;Dilara Tarim
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2734-2741
    • /
    • 2023
  • Brachytherapy is a special case of radiotherapy. It should be arranged according to some principles in medical radiation applications and radiation physics. The primary principle is to use as low as reasonably achievable dose in all ionizing radiation applications for diagnostic and therapeutic treatments. Dosimetric distributions are dependent on radioactive source properties and radiation-matter interactions in an absorber medium such as phantom or tissue. In this consideration, the geometrical structure and material of the seed capsule, which surrounds a radioactive material, are directly responsible for isodose profiles and dosimetric functions. In this study, the radiometric properties of capsule material were investigated on dose distribution in a water phantom by changing its nuclear properties using the EGSnrc Monte Carlo (MC) simulation code. Effective atomic numbers of hypothetic mixtures were calculated by using different elements with several fractions for capsule material. Model 6711 brachytherapy seed was modeled by EGSnrc/Dosrcnrc Code and dosimetric functions were calculated. As a result, dosimetric parameters of hypothetic sources have been acquired in large-scale atomic number. Dosimetric deviations between the data of hypothetic seeds and the original one were analyzed. Unit dose (Gy/Particle) distributions belonging to different types of material in seed capsule have remarkably differed from the original capsule's data. Capsule type is major variable to manage the expected dose profile and isodose distribution around a seed. This study shows us systematically varied scale of material type (cross section or effective atomic number dependent) offers selective material usage in production of seed capsules for the expected isodose profile of a specific source.