• Title/Summary/Keyword: effective confining pressure

Search Result 75, Processing Time 0.02 seconds

An Effective Pressure Law for the Transport Property of Granite (화강암의 수리적 특성을 고려한 유효압력법칙)

    • Tunnel and Underground Space
    • /
    • v.7 no.4
    • /
    • pp.293-298
    • /
    • 1997
  • Permeability was not represented as a simple function of the difference between confining pressure($P_c$) and pore pressure($P_p$). The effective pressure($P_e$) for measurements of the permeability is shown to be $P_c-{\alpha}P_p$, where $\alpha$ is a coefficient of effective pressure. Local values of $\alpha$ were determined at intervals along the pressure path which range 25MPa to 55MPa. The values of $\alpha$ ranged 0.65 to 1.09 for Pocheon granite and 1.20 to 1.43 for Wonju granite. Also, the value of $\alpha$ calculated by the cross-plotting method was 0.90 for Pocheon granite, 1.59 for Wonju granite and 4.35 for jointed Pocheon granite. $\alpha$ was found to be stress-history dependent.

  • PDF

Strength enhancement in confined concrete with consideration of flexural flexibilities of ties

  • Teerawong, J.;Lukkunaprasit, P.;Senjuntichai, T.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.2
    • /
    • pp.151-166
    • /
    • 2004
  • The interaction between concrete core expansion and deformation of perimeter ties has been known to have a significant effect on the effective confinement of rectangular reinforced concrete (RC) tied columns. This interaction produces passive confining pressure to the concrete core. Most existing models for determining the response of RC tied columns do not directly account for the influence of flexural stiffness of the ties and the variation of confining stress along the column height. This study presents a procedure for determining the confined compressive strength of RC square columns confined by rectilinear ties with various tie configurations considering directly the influence of flexural flexibility of the ties and the variation of confining stress along the vertical direction. The concept of area compatibility is employed to ensure compatibility of the concrete core and steel hoop in a global sense. The proposed procedure yields satisfactory predictions of confined strengths compared with experimental results, and the influence of tie flexibility, tie configuration and degree of confinement can be well captured.

세립분 함유량에 따른 새만금준설토의 액상화 특성에 관한 연구

  • Kim, You-Seong;Lee, Soo-Guen;Ko, Hyoung-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1458-1465
    • /
    • 2010
  • A lot of dredging and reclaming projects are recently under way in Korea for the efficient use of limiting land space. Saemanguem area is special case of reclaiming by dredged soil. In case of a confined disposal of dredged soils by a pump dredger, generally coarse grained soils are separated from fines with dropping at the near part of the pump dredger. This kind of seperation of fine contents could be a factor of liquefaction by earthquake. In Korea, recently, earthquakes with magnitude of 3.0 or higher are distinctively increasing in 1990. In this study, cyclic shear characterics of Saemanguem Dredged sand depending on fine content were analyzed. A series of undrained cyclic triaxial test with cyclic stress ratio ($\sigma_d/{2\sigma_{{\upsilon}c}}'$) were performed on both isotropic consolidated specimen and sand with fine contents of 0%, 5%, 15%, 30%, 40% under the effective vertical stress of 100kPa and 50% and 60%, 70% of relative density for fine content of 0%, respectively. In the test results, cyclic shear strength increased by increasing of cyclic stress ratio($\sigma_d/{2\sigma_{{\upsilon}c}}'$) with increasing the relative density at the same number of cyclic under the effective confining pressure of 100kPa. It is almost highest the double amplitude(DA) 1%, 3%, 5%, 7.5% and 10% at fine content of 15% between Cyclic stress ratio($\sigma_d/{2\sigma_{{\upsilon}c}}'$) value at cyclic number five and fine content. Number of cyclic is 30 under the effective vertical stress of 100kPa, 70% of relative density for fine content of 15%. when the cyclic stress ratio at each relative density was compared at cyclic number five, the double amplitude(DA) 1%, 3%, 5%, 7.5% and 10%, and the pore-pressure ratio (${\Delta}u/{\sigma'}_c$) 0.95 value were compared; under the relative density of 70% and the effective confining pressure of 100kPa. The pore-pressure ratio (${\Delta}u/{\sigma'}_c$) 0.95 value showed a similar trend to the double amplitude (DA) 5% line.

  • PDF

The Effect of Soil Water Retention Curves under Confining Stress on the Effective Stress in Variably Saturated Soils (구속응력에 따른 함수특성곡선이 변포화토의 유효응력에 미치는 효과)

  • Oh, Seboong;Lee, Young-Hu;Bae, Im-Soo;Kim, Sang-Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4C
    • /
    • pp.169-175
    • /
    • 2012
  • Soil water retention characteristics are influenced by factors of the confining stress and hysteresis in the variably saturated soil. In the description of effective stress based on hydraulic characteristics, the contribution of a matric suction to effective stress then varies with depth or is different between the processes of infiltration and evaporation. Unsaturated effective stress can be described based on suction stress characteristic curve, in which a representative soil water retention curve is required to evaluate. Pressure palate extractor tests under various confining stresses were performed and the hysteresis of drying and wetting process was also acquired. In the process of drying or wetting, a unique relationship has been estimated on the effective volumetric water content and the matric suction, which defines suction stress characteristic curve. In the unsaturated shear strength from triaxial tests, the suction stress and the effective stress were evaluated by matric suctions. The failure envelop by effective stress based on soil water retention characteristics was unique and the same as the saturated one. The measured suction stress from triaxial tests was similar to that from the soil water retention curve. Therefore it is verified that a representative soil water retention curve can be defined which is independent of the confining effect under wetting or drying process of the hysteresis.

A Suggestion of an Empirical Equation for Shear Modulus Reduction Curve Estimation of Sandy Soils (사질토 전단탄성계수 감소곡선 산정을 위한 경험식 제안)

  • Park, Dug-Keun
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.126-126
    • /
    • 2002
  • In dynamic analyses such as seismic ground response and soil-structure interaction problems, it is very crucial to obtain accurate dynamic shear modulus of soil deposit. In this study, an extensive data base of available experimental data is compiled and reanalyzed to establish a simple empirical formula for the dynamic shear modulus reduction curve to cover wide range of strain for sandy soils. The proposed empirical equation is to represent the dynamic shear modulus degradation with strain in terms of low-amplitude dynamic shear modulus and effective mean confining Pressure, since those factors have the most significant effect on the Position and shape of the shear modulus reduction curve for nonelastic soils. If low-amplitude shear modulus is measured, degraded modulus at any shear strain amplitude can be calculated using the proposed equation.

A Suggestion of an Empirical Equation for Shear Modulus Reduction Curve Estimation of Sandy Soils (사질토 전단탄성계수 감소곡선 산정을 위한 경험식 제안)

  • Park, Dug-Keun
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.127-138
    • /
    • 2002
  • In dynamic analyses such as seismic ground response and soil-structure interaction problems, it is very crucial to obtain accurate dynamic shear modulus of soil deposit. In this study, an extensive data base of available experimental data is compiled and reanalyzed to establish a simple empirical formula for the dynamic shear modulus reduction curve to cover wide range of strain for sandy soils. The proposed empirical equation is to represent the dynamic shear modulus degradation with strain in terms of low-amplitude dynamic shear modulus and effective mean confining Pressure, since those factors have the most significant effect on the Position and shape of the shear modulus reduction curve for nonelastic soils. If low-amplitude shear modulus is measured, degraded modulus at any shear strain amplitude can be calculated using the proposed equation.

Lateral strain-axial strain model for concrete columns confined by lateral reinforcement under axial compression

  • Hou, Chongchi;Zheng, Wenzhong
    • Structural Engineering and Mechanics
    • /
    • v.84 no.2
    • /
    • pp.239-251
    • /
    • 2022
  • The use of lateral reinforcement in confined concrete columns can improve bearing capacity and deformability. The lateral responses of lateral reinforcement significantly influence the effective confining pressure on core concrete. However, lateral strain-axial strain model of concrete columns confined by lateral reinforcement has not received enough attention. In this paper, based on experimental results of 85 concrete columns confined by lateral reinforcement under axial compression, the effect of unconfined concrete compressive strength, volumetric ratio, lateral reinforcement yield strength, and confinement type on lateral strain-axial strain curves was investigated. Through parameter analysis, it indicated that with the same level of axial strain, the lateral strain slightly increased with the increase in the unconfined concrete compressive strength, but decreased with the increase in volumetric ratio significantly. The lateral reinforcement yield strength had slight influence on lateral strain-axial strain curves. At the same level of lateral strain, the axial strain of specimen with spiral was larger than that of specimen with stirrup. Furthermore, a lateral strain-axial strain model for concrete columns confined by lateral reinforcement under axial compression was proposed by introducing the effects of unconfined concrete compressive strength, volumetric ratio, confinement type and effective confining pressure, which showed good agreement with the experimental results.

Comparative analysis of damping ratio determination methods based on dynamic triaxial tests

  • Song Dongsong;Liu Hongshuai
    • Earthquakes and Structures
    • /
    • v.25 no.4
    • /
    • pp.249-267
    • /
    • 2023
  • Various methods for determining the damping ratio have been proposed by scholars both domestically and abroad. However, no comparative analysis of different determination methods has been seen yet. In this study, typical sand (Fujian standard sand) and cohesive soils were selected as experimental objects, and undrained strain-controlled dynamic triaxial tests were conducted. The differences between existing damping ratio determination methods were theoretically compared and analyzed. The results showed that the hysteresis curve of cohesive soils had better symmetry and more closely conformed to the definition of equivalent linear viscoelasticity. For non-cohesive soils, the differences in damping ratio determined by six methods were significant. The differences decreased with increasing confining pressure and relative density, but increased gradually with increasing shear strain, especially at high shear strains, where the maximum relative error reached 200%. For cohesive soils, the differences in damping ratio determined by six methods were relatively small, with a maximum relative error of about 50%. Moreover, they were less affected by effective confining pressure and had the same changing trend under different effective confining pressures. The damping ratio determination method has a large effect on the seismic response of soils distributed by non-cohesive soils, with a maximum relative error of about 15% for the PGA and up to about 30% for the Sa. However, for soil layers distributed by cohesive soils, the damping ratio determination method has less influence on the seismic response. Therefore, it is necessary to adopt a unified damping ratio determination method for non-cohesive soils, which can effectively avoid artificial errors caused by different determination methods.

Velocity-effective stress response of $CO_2$-saturated sandstones ($CO_2$로 포화된 사암의 속도-유효응력 반응)

  • Siggins, Anthony F.
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.60-66
    • /
    • 2006
  • Three differing sandstones, two synthetic and one field sample, have been tested ultrasonically under a range of confining pressures and pore pressures representative of in-situ reservoir pressures. These sandstones include: a synthetic sandstone with calcite intergranular cement produced using the CSIRO Calcite In-situ Precipitation Process (CIPS); a synthetic sandstone with silica intergranular cement; and a core sample from the Otway Basin Waarre Formation, Boggy Creek 1 well, from the target lithology for a trial $CO_2$ pilot project. Initial testing was carried on the cores at "room-dried" conditions, with confining pressures up to 65 MPa in steps of 5 MPa. All cores were then flooded with $CO_2$, initially in the gas phase at 6 MPa, $22^{\circ}C$, then with liquid-phase $CO_2$ at a temperature of $22^{\circ}C$ and pressures from 7 MPa to 17 MPa in steps of 5 MPa. Confining pressures varied from 10 MPa to 65 MPa. Ultrasonic waveforms for both P- and S-waves were recorded at each effective pressure increment. Velocity versus effective pressure responses were calculated from the experimental data for both P- and S-waves. Attenuations $(1/Q_p)$ were calculated from the waveform data using spectral ratio methods. Theoretical calculations of velocity as a function of effective pressure for each sandstone were made using the $CO_2$ pressure-density and $CO_2$ bulk modulus-pressure phase diagrams and Gassmann effective medium theory. Flooding the cores with gaseous phase $CO_2$ produced negligible change in velocity-effective stress relationships compared to the dry state (air saturated). Flooding with liquid-phase $CO_2$ at various pore pressures lowered velocities by approximately 8% on average compared to the air-saturated state. Attenuations increased with liquid-phase $CO_2$ flooding compared to the air-saturated case. Experimental data agreed with the Gassmann calculations at high effective pressures. The "critical" effective pressure, at which agreement with theory occurred, varied with sandstone type. Discrepancies are thought to be due to differing micro-crack populations in the microstructure of each sandstone type. The agreement with theory at high effective pressures is significant and gives some confidence in predicting seismic behaviour under field conditions when $CO_2$ is injected.

Ultimate strength of rectangular concrete-filled steel tubular (CFT) stub columns under axial compression

  • Huang, Yan-Sheng;Long, Yue-Ling;Cai, Jian
    • Steel and Composite Structures
    • /
    • v.8 no.2
    • /
    • pp.115-128
    • /
    • 2008
  • A method is proposed to estimate the ultimate strength of rectangular concrete-filled steel tubular (CFT) stub columns under axial compression. The ultimate strength of concrete core is determined by using the conception of the effective lateral confining pressure and a failure criterion of concrete under true triaxial compression, which takes into account the difference between the lateral confining pressure provided by the broad faces of the steel tube and that provided by the narrow faces of the steel tube. The longitudinal steel strength of broad faces and that of the narrow faces of the steel tube are calculated respectively due to that buckling tends to occur earlier and more extensively on the broader faces. Finally, the proposed method is verified with experimental results. Corresponding values of ultimate strength calculated by ACI (2005), AISC (1999) and GJB4142-2000 are given respectively for comparison. It is found from comparison that the proposed method shows a good agreement with the experimental results.