• Title/Summary/Keyword: effective

Search Result 86,994, Processing Time 0.084 seconds

A Study on Correlation of Effective Discharge Energy and Exhaust Emission of Gasoline Vehicle (가솔린자동차의 유효방전에너지와 배기가스와의 상관관계 연구)

  • Yoo, Jongsik;Kim, Chulsoo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.70-75
    • /
    • 2014
  • The experiment was done on traveling at the speed of 20km/h, 60km/h and 100km/h using the performance testing mode for chassis dynamometer. The experimental method were employed to measure the waveform of secondary ignition coil and exhaust emission. In this experiment, the correlation between the secondary waveform coming from ignition coil and exhaust emission were measured in decrepit vehicle. The secondary waveform characterized by the value of effective discharge energy. The following results are obtained by analyzing the data relativity between the effective discharge energy and exhaust emission. The variation rate of effective discharge energy was largest 60km/h, 20km/h, 100km/h velocity in the ordered named. As the vehicle velocity increases, the average variation rate of CO and $NO_X$ decreases and that of HC and $CO_2$ decrease. The value of effective discharge energy, CO, $NO_X$ and fuel consumption is measured badly in case of car with failures in MAP, spark plug and good in case of car with before and after maintenance regardless of vehicle velocities. The value of effective discharge energy is to be nearly parabolic shape as vehicle velocity increases. As the value of effective discharge energy increases, the value of $NO_X$, HC and $CO_2$ decrease, the value of CO increase. The most sensible factors of exhaust emission were CO, $NO_X$, and the small variation factors were HC, $CO_2$.

Prediction for the Lifetime Effective Dose and Radon Exposure Risk by using Dose Conversion Convention: Base on the Indoor Radon Concentration of Lecture Room in a University (선량 환산 관례를 이용한 생애유효선량 및 라돈피폭 위험도 예측: 대학 강의실 라돈농도 중심으로)

  • Lee, Jae-Seung;Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.243-249
    • /
    • 2018
  • The indoor radon concentration was measured in the lecture room of the university and the radon concentration was converted to the amount related to the radon exposure using the dose conversion convention and compared with the reference levels for the radon concentration control. The effect of indoor radon inhalation was evaluated by estimating the life effective dose and the risk of exposure. To measure the radon concentration, measurements were made with a radon meter and a dedicated analysis Capture Ver. 5.5 program in a university lecture room from January to February 2018. The radon concentration measurement was carried out for 5 consecutive hours for 24 hours after keeping the airtight condition for 12 hours before the measurement. Radon exposure risk was calculated using the radon dose and dose conversion factor. Indoor radon concentration, radon exposure risk, and annual effective dose were found within the 95% confidence interval as the minimum and maximum boundary ranges. The radon concentration in the lecture room was $43.1-79.1Bq/m^3$, and the maximum boundary range within the 95% confidence interval was $77.7Bq/m^3$. The annual effective dose was estimated to be 0.20-0.36 mSv/y (mean 0.28 mSv/y). The life-time effective dose was estimated to be 0.66-1.18 mSv (mean $0.93{\pm}0.08mSv$). Life effective doses were estimated to be 0.88-0.99 mSv and radon exposure risk was estimated to be 12.4 out of 10.9 per 100,000. Radon concentration was measured, dose effective dose was evaluated using dose conversion convention, and degree of health hazard by indoor radon exposure was evaluated by predicting radon exposure risk using nominal hazard coefficient. It was concluded that indoor living environment could be applied to other specific exposure situations.

Effect of packing structure on anisotropic effective thermal conductivity of thin ceramic pebble bed

  • Wang, Shuang;Wang, Shuai;Wu, Bowen;Lu, Yuelin;Zhang, Kefan;Chen, Hongli
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2174-2183
    • /
    • 2021
  • Helium cooled solid breeder blanket as an important blanket candidate of the Tokamak fusion reactor uses ceramic pebble bed for tritium breeding. Considering the poor effective thermal conductivity of the ceramic breeder pebble bed, thin structure of tritium breeder pebble bed is usually adopted in the blanket design. The container wall has a great influence on the thin pebble bed packing structure, especially for the assembly of mono-sized particles, and thin pebble bed will appear anisotropic effective thermal conductivity phenomenon. In this paper, thin ceramic pebble beds composed of 1 mm diameter Li4SiO4 particles are generated by the EDEM 2.7. The effective thermal conductivity of different thickness pebble beds in the three-dimensional directions are analyzed by three-dimensional thermal network method. It is observed that thin Li4SiO4 pebble bed showing anisotropic effective thermal conductivity under the practical design size. Normally, the effective thermal conductivity along the bed vertical direction is higher than the horizontal direction due to the gravity effect. As the thickness increases from 10 mm to 40 mm, the effective thermal conductivity of the pebble bed gradually increases.

Developing the Nuclear Effective Safety Index (원자력 발전소 안전체감에 관한 연구: 안전체감지수 개발과 안전체감 수준)

  • Incheol Choi ;Beom Jun Kim
    • Korean Journal of Culture and Social Issue
    • /
    • v.13 no.3
    • /
    • pp.1-21
    • /
    • 2007
  • The present research was conducted 1) to explore the factor structure of 'effective safety' and 2) to develop an index of effective safety. We recuited a total of 800 residents of the nuclear plant sites and 187 nuclear plant employers. Study 1 developed a scale of nuclear effective safety which consisted of four factors: Communication, Trust, Coping Ability of nuclear power plants, Emergency Coping Skills. We created the index of effective safety by converting the scale scores into a number 0 to 100. Overall, the index was very low 38..22, indicating that the residents of nuclear power plants sites were feeling very insecure about the safety of nuclear power plants. Moreover we found a consistent pattern of regional and sex difference. In Study 2, we asked the employees of nuclear power plants to answer the scale as if they were the residents, and we compared these numbers with the numbers the actual residents provided. We found that the level of safety that the employees expected the residents to experience was significantly higher than the level of safety the residents were actually experiencing. We discussed the pratical implications of the present findings.

  • PDF

General Radiography Imaging Usage and Effective Dose of Inpatients: Based on Data from Inpatients in 2018 (입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터)

  • Jong-Won Gil
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.107-116
    • /
    • 2024
  • In this study, we analyzed the use of general radiography imaging and effective dose in inpatients. Our aim is to help reduce national medical radiation exposure doses and develop rational health-care financial policies. The effective dose for each general radiography was calculated using the ALARA-GR program for 53 types (total: 260 codes) general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2018 inpatient patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was analyzed. 89.00% of inpatients undergo general radiography imaging at least once, with an average of 12.63 scans per person and an effective dose of 1.00 mSv. Those who received support from Medical Aid showed a higher value compared to those who were insured by National Health Insurance, with 17.39 cases and 1.43 mSv (p<.001). Chest had the highest usage rate at 23.12% for general radiography imaging, while L-spine had the highest effective dose at 24.53%. It is estimated that 420 inpatients patients undergo 121 to 820 general radiography imaging procedures per year, and 233 inpatients are estimated to have an annual effective dose of >20.00~58.25 mSv. Rational use of health-care finances and the practice of medical radiation safety management are essential for the well-being of individuals, the enhancement of quality of life, and the improvement of health-care quality.

Short and Effective Reset Method for AC PDPs

  • Kim, Joon-Yub;Lee, In-Moo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.241-245
    • /
    • 2006
  • Reset is necessary for effective addressing in AC PDPs, but reset takes considerable time and produces background luminance. A reset method that takes less time but is effective for addressing is presented. Furthermore, this reset method produces almost negligible background luminance.

  • PDF

Effective Maritime Search and Rescue

  • Redfern, A.
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.2 no.1
    • /
    • pp.121-123
    • /
    • 1996
  • Technical developments, particularly in communications, increase the potential for effective maritime search and rescue(SAR). The paper identifies some of the questions those seeking to proveid effective SAR service should ask, and outlines possible answers.

  • PDF

Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy (고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정)

  • Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.98-103
    • /
    • 2014
  • Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

  • PDF

Teachers' Knowledge Base and The Structure of Mathematical Knowledge for Effective Mathematics Teaching (효과적인 수학 교수를 위한 교사 지식 기반 영역과 수학적 지식 구조)

  • Kim, Young-Ok
    • Journal of the Korean School Mathematics Society
    • /
    • v.11 no.4
    • /
    • pp.595-608
    • /
    • 2008
  • The purpose of this study is to address the teachers' knowledge bases for effective mathematics teaching and especially to provide the various definitions and the structures of mathematics knowledge which is the most important one of the knowledge bases. The conceptual understanding about teachers' knowledge bases for effective mathematics teaching and the structure of mathematics knowledge may be used in evaluating effective mathematics teaching and teachers as well as in developing a new conceptual framework for the structure of mathematical knowledge.

  • PDF

Statistical Model of Effective Impact Speed based on Vehicle Damages in Case of Rear-End Collisions

  • Kang, Sung-Mo;Kim, Joo-Hwan
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.2
    • /
    • pp.463-473
    • /
    • 2008
  • In this study, we measure damage depth and calculate effective impact speed in case of rear-end collision using real car insurance data. We study the relationship between demage depth and effective impact speed, and present statistical model for these two variables. In our real data study, 3-degree polynomial equation model is better fit to effective impact speed and demage depth than the simple linear model that are estimated in previous other studies. Damage depth is a major factor to see the extent of impact in a car collision, and by using this equation, it is possible to evaluate the severity of driver's injury.

  • PDF